Honeywell PCB CS0147C-LS Saunier Duval Thema NOx F24

Honeywell CS0147C-LS PCB Saunier Duval Thema NOX F24

Stock · 1 unit

Control PCB identified by its silkscreen: manufacturer Honeywell, code CS0147C-LS. It includes a Schrack relay PE014024 (PCB reference 052.003714/01) and two class X2 capacitors of 47 nF at 305 V for network filtering. It is installed in Saunier Duval boilers from the Master Inox, Supermaster, Supermicra, and Thema NOX ranges. It is replaced when the module stops functioning.

VAT included

Compatibility

Boilers compatible with reference 0020076179

PCB with reference 0020076179. Eight confirmed compatibilities: F 24 and 24 SE.

Proven compatibility

Boiler modelFamilyVerification
F 24NOX ThemaContrasted
24 SESupermasterContrasted
28 SESupermasterContrasted
30 SESupermasterContrasted
Ecoplus 24 SESupermicraContrasted
Master Inox 24 SEHermannContrasted
Master Inox 30 SEHermannContrasted
Supermicra Condensing 24 SEHermannContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020076179 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020076179. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 0020076179 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start: there is no power or display.

    Cause: The PCB is the control unit that manages the entire system; if it fails, the equipment does not respond.

    Check the fuse on the PCB and ensure that it is receiving power at the input before replacing the entire module.

  • 02

    An error code appears on the screen that does not go away after resetting.

    Cause: The microcontroller on the PCB detects a problem with the sensors or safety stages and locks the unit.

    Note the exact code displayed on the screen: not all codes indicate a fault in the PCB.

  • 03

    The thermostat does not control the boiler even when it is on.

    Cause: Communication between the thermostat and the PCB is interrupted if the corresponding input stage fails.

    Try to operate the boiler in manual mode from the unit itself, without the thermostat, to determine if the fault is in the PCB or in the thermostat.

  • 04

    The boiler turns on and off by itself intermittently.

    Cause: A relay or capacitor on the PCB in poor condition causes interruptions in the power supply to the components.

    Check for any visible moisture or dirt on the PCB and ensure that the connectors are securely attached before replacing it.

Fault codes that this part resolves

CodeFaultDiagnosis and solution
13Main PCB fault.The main PCB is faulty or has defective internal/external connections; check the fuse and voltages of the PCB (230/5 V supplies) and connectors. If the issue persists with correct wiring and peripherals, replace the PCB.
11No reception from the main PCB (MMI line).Communication fault towards the PCB (receiver/MMI input of the PCB) or the cable between interface and PCB; check continuity of the MMI lead and 5 V on the interface. If the fault persists with a good cable/panel, the PCB is the cause.
26Gas valve not functioning.The stepper motor of the valve assembly is not responding. Check that the PCB's multi-connector is properly plugged in and that the wiring harness is not interrupted; if the motor and wiring are fine, the cause is the electronics.
27Incorrect flame detection: safety shutdown.Moisture in the electronics, faulty flame control, or defective gas solenoid valve. Dry and check the solenoid valve before replacing the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the PCB 0020076179

Catalogue reference
0020076179
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component manufacturer
Honeywell
Component code
CS0147C-LS
Relay
Schrack PE014024 (PCB reference 052.003714/01)
Capacitor X2
47 nF, 305 V~ (marked AN106254251 C), 2 units
Frequently Asked Questions

Frequently asked questions about the PCB 0020076179

Who manufactures the CS0147C-LS PCB of the Saunier Duval Thema NOX F24?
The module has the Honeywell silkscreen with the code CS0147C-LS.
What relay is mounted on the Honeywell CS0147C-LS PCB?
A Schrack relay PE014024, referenced on the board itself as 052.003714/01.
Does this Honeywell CS0147C-LS PCB work for any Saunier Duval boiler?
No; only for the models in the list of compatible ones, including the Master Inox, Supermaster, Supermicra ranges and the Thema NOX F24.
What capacitors does the CS0147C-LS PCB of the Thema NOX F24 have?
Two class X2 capacitors of 47 nF at 305 V, used for mains filtering.
Does this Honeywell CS0147C-LS PCB work for the Saunier Duval Supermicra Condensing 24 SE?
Yes, the Supermicra Condensing 24 SE is on the list of boilers compatible with this PCB.

Spare parts related to Supermaster

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell PCB CS0147C-LS Saunier Duval Thema NOx F24