Stock · 5 units

Pressure switch for the Hermann Micra 2 boiler and related models in the range. Manufactured by Honeywell, code C6065FH1821:2, with the Yamatake brand also printed on the label. It is an NC-NO switch that operates based on the detected pressure (P = 1.04 mbar, maximum 6 mbar) and interrupts or enables the boiler circuit. It is replaced when a pressure lockout or error occurs and the unit does not start.

VAT included

Compatibility

Hermann boilers compatible with reference 049003163

Pressure switch with reference 049003163. 12 verified compatibilities: Micra 2 24 E and Micra 2 24-30 SE.

Proven compatibility

Boiler modelFamilyVerification
Hermann Micra 2 24 EHermann/Renova Micra 2Contrasted
Hermann Micra 2 24-30 SEHermann/Renova Micra 2Contrasted
Hermann Micra 2.24 SEHermann/Renova Micra 2Contrasted
Hermann Micra 23 SEHermann/Renova MicraContrasted
Hermann Micra 24 EHermann/Renova MicraContrasted
Hermann Micra 24 SEHermann/Renova MicraContrasted
Hermann Supermicra 28 EHermann/Renova SupermicraContrasted
Hermann Supermicra 30 SEHermann/Renova SupermicraContrasted
Hermann Supermicra Ecoplus 24 SEHermann/Renova SupermicraContrasted
Hermann Habitat 23 SEHermann/Renova HabitatContrasted
Hermann Habitat Plus 23 EHermann/Renova HabitatContrasted
Hermann Habitat 2 - 23 EHermann/Renova HabitatContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 049003163 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 049003163. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 049003163 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is locking out with a pressure fault and the burner does not ignite.

    Cause: The pressure switch does not close the contact that allows ignition, so the control board thinks that the pressure is not correct and interrupts the sequence.

    Before replacing it, check that the pressure switch connection tube is not blocked, bent, or disconnected.

  • 02

    The boiler works well, but the burner never ignites.

    Cause: This indicates that the pressure switch is not providing the continuity signal, even though the actual pressure is correct.

    Measure with a multimeter if there is continuity in the terminals of the pressure switch when the pressure should be sufficient for it to operate.

  • 03

    The pressure switch gets stuck or does not respond after not using the boiler, such as after the summer.

    Cause: The internal contacts can oxidize or seize up over time and with lack of use, preventing them from making the 'click' when changing pressure.

    Before replacing it, try to operate it manually if possible, or gently tap it to see if it responds after being idle.

  • 04

    The pressure lock occurs suddenly, without having touched anything in the installation.

    Cause: The wear of the diaphragm or the NC-NO contact can fail without prior warning, unrelated to any recent handling.

    First, check if there is a leak or a real drop in pressure in the circuit with a manometer, so you don't change the pressure switch if the problem is a real pressure issue.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Hermann 049003163 pressure switch datasheet

Catalogue reference
049003163
Brand
Hermann
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Honeywell (Yamatake brand printed alongside Honeywell on the label)
Component code
C6065FH1821:2
Voltage
250V~
Contact upload
1.5(0.5) [unit not clear on the label, possibly A]
Switching pressure (P+)
1.04 mbar
Maximum pressure
6 mbar
CE code
CE-0063AP3085/1
Date/lot code
0705F
Place of manufacture
Made in China
Frequently Asked Questions

Frequently asked questions about the pressure switch 049003163

For which Hermann boilers is the Honeywell pressure switch Hermann Micra 2 Ref. 049003163 compatible?
It is compatible with the following models: Micra 2 24 E, Micra 2 24-30 SE, Micra 2.24 SE, Micra 23 SE, Micra 24 E, Micra 24 SE, Supermicra 28 E, Supermicra 30 SE, Supermicra Ecoplus 24 SE, Habitat 23 SE, Habitat Plus 23 E, and Habitat 2 - 23 E.
What fault indicates that the pressure switch needs to be replaced in the Hermann Micra 2 boiler?
It should be replaced when a blockage or pressure fault occurs and the boiler does not start.
What is the reference of the pressure switch I need for my boiler?
The reference of the pressure switch is PCCHM2.
How many boiler models are compatible with this pressure switch?
A total of 12 models are compatible with the Honeywell Hermann Micra 2 pressure switch Ref. 049003163.
What type of pressure switch is the Honeywell Hermann Micra 2?
It is a pressure switch designed for boilers in the Hermann/Renova range.
Are there documented fault codes for this pressure switch?
No, there are no documented fault codes for this product.

Spare parts related to Hermann Hermann/Renova Micra 2

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell Pressure Switch Hermann Micra 2 Ref. 049003163