Honeywell Pressure Switch Hermann Micra 2 Ref. 049003163
Differential air pressure switch Honeywell C6065FH1821:2, cataloged with reference 049003163. It monitors the air circuit and combustion exhaust; it does not measure the heating water pressure. Check the complete code, the setting, and the connections with the original part and the equipment breakdown. Replacement requires prior technical diagnosis.
- Type of part
- Pressure switches
- Status
- Refurbished
- Catalogue reference
- 049003163
- Warranty
- 1 year
Hermann boilers compatible with reference 049003163
Pressure switch with reference 049003163. 12 verified compatibilities: Micra 2 24 E and Micra 2 24-30 SE.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Hermann Micra 2 24 E | Hermann/Renova Micra 2 | Contrasted |
| Hermann Micra 2 24-30 SE | Hermann/Renova Micra 2 | Contrasted |
| Hermann Micra 2.24 SE | Hermann/Renova Micra 2 | Contrasted |
| Hermann Micra 23 SE | Hermann/Renova Micra | Contrasted |
| Hermann Micra 24 E | Hermann/Renova Micra | Contrasted |
| Hermann Micra 24 SE | Hermann/Renova Micra | Contrasted |
| Hermann Supermicra 28 E | Hermann/Renova Supermicra | Contrasted |
| Hermann Supermicra 30 SE | Hermann/Renova Supermicra | Contrasted |
| Hermann Supermicra Ecoplus 24 SE | Hermann/Renova Supermicra | Contrasted |
| Hermann Habitat 23 SE | Hermann/Renova Habitat | Contrasted |
| Hermann Habitat Plus 23 E | Hermann/Renova Habitat | Contrasted |
| Hermann Habitat 2 - 23 E | Hermann/Renova Habitat | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 049003163 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 049003163. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the pressure switch 049003163
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Ignition lockout or air supervision fault
Cause: It can have various causes in the air circuit, exhaust, connections, or control. The symptom does not identify a faulty part on its own.
A technician must check the system according to the equipment manual. Do not short-circuit, hit, or modify the setting of the pressure switch.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Hermann 049003163 pressure switch datasheet
- Catalogue reference
- 049003163
- Uniclima internal SKU
- PCCHM2
- Brand
- Hermann
- Type of part
- Pressure switches
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Manufacturer
- Honeywell (Yamatake brand printed alongside Honeywell on the label)
- Component code
- C6065FH1821:2
- Voltage
- 250V~
- Contact upload
- 1.5(0.5) [unit not clear on the label, possibly A]
- Switching pressure (P+)
- 1.04 mbar
- Maximum pressure
- 6 mbar
- CE code
- CE-0063AP3085/1
- Date/lot code
- 0705F
- Place of manufacture
- Made in China