Honeywell Pressure Switch Hermann Micra 2 Ref. 049003163

Honeywell Pressure Switch Hermann Micra 2 Ref. 049003163

Differential air pressure switch Honeywell C6065FH1821:2, cataloged with reference 049003163. It monitors the air circuit and combustion exhaust; it does not measure the heating water pressure. Check the complete code, the setting, and the connections with the original part and the equipment breakdown. Replacement requires prior technical diagnosis.

Type of part
Pressure switches
Catalogue reference
049003163
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Hermann boilers compatible with reference 049003163

Pressure switch with reference 049003163. 12 verified compatibilities: Micra 2 24 E and Micra 2 24-30 SE.

Proven compatibility

Boiler modelFamilyVerification
Hermann Micra 2 24 EHermann/Renova Micra 2Contrasted
Hermann Micra 2 24-30 SEHermann/Renova Micra 2Contrasted
Hermann Micra 2.24 SEHermann/Renova Micra 2Contrasted
Hermann Micra 23 SEHermann/Renova MicraContrasted
Hermann Micra 24 EHermann/Renova MicraContrasted
Hermann Micra 24 SEHermann/Renova MicraContrasted
Hermann Supermicra 28 EHermann/Renova SupermicraContrasted
Hermann Supermicra 30 SEHermann/Renova SupermicraContrasted
Hermann Supermicra Ecoplus 24 SEHermann/Renova SupermicraContrasted
Hermann Habitat 23 SEHermann/Renova HabitatContrasted
Hermann Habitat Plus 23 EHermann/Renova HabitatContrasted
Hermann Habitat 2 - 23 EHermann/Renova HabitatContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 049003163 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 049003163. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the pressure switch 049003163

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    Ignition lockout or air supervision fault

    Cause: It can have various causes in the air circuit, exhaust, connections, or control. The symptom does not identify a faulty part on its own.

    A technician must check the system according to the equipment manual. Do not short-circuit, hit, or modify the setting of the pressure switch.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Hermann 049003163 pressure switch datasheet

Catalogue reference
049003163
Uniclima internal SKU
PCCHM2
Brand
Hermann
Type of part
Pressure switches
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Honeywell (Yamatake brand printed alongside Honeywell on the label)
Component code
C6065FH1821:2
Voltage
250V~
Contact upload
1.5(0.5) [unit not clear on the label, possibly A]
Switching pressure (P+)
1.04 mbar
Maximum pressure
6 mbar
CE code
CE-0063AP3085/1
Date/lot code
0705F
Place of manufacture
Made in China
Frequently Asked Questions

Frequently asked questions about the pressure switch 049003163

For which Hermann boilers is the Honeywell pressure switch Hermann Micra 2 Ref. 049003163 compatible?
It is compatible with the following models: Micra 2 24 E, Micra 2 24-30 SE, Micra 2.24 SE, Micra 23 SE, Micra 24 E, Micra 24 SE, Supermicra 28 E, Supermicra 30 SE, Supermicra Ecoplus 24 SE, Habitat 23 SE, Habitat Plus 23 E, and Habitat 2 - 23 E.
What fault indicates that the pressure switch needs to be replaced in the Hermann Micra 2 boiler?
A blockage or fault is not enough to decide on a replacement. It must be confirmed through diagnosis of the air and exhaust circuit according to the equipment manual.
What is the reference of the pressure switch I need for my boiler?
PCCHM2 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
How many boiler models are compatible with this pressure switch?
A total of 12 models are compatible with the Honeywell Hermann Micra 2 pressure switch Ref. 049003163.
What type of pressure switch is the Honeywell Hermann Micra 2?
It is a Honeywell C6065FH1821:2 differential air pressure switch, not a heating water pressure sensor.
Are there documented fault codes for this pressure switch?
No, there are no documented fault codes for this product.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Honeywell Pressure Switch Hermann Micra 2 Ref. 049003163