Honeywell PCB Junkers Euroline ZW23 1KE31 Bosch Ref. 87083002120

Honeywell PCB Junkers Euroline ZW23 1KE31 Bosch Ref. 87083002120

If your boiler does not start, locks out, or exhibits erratic behavior, a technical diagnosis must confirm if you need the Honeywell Junkers Euroline ZW23 1KE31 Bosch Ref. 87083002120 control PCB. This control board is responsible for managing the ignition, burner modulation, pump, and safety features of the boiler. Symptoms of failure include the reset button flashing at 0.5 Hz or 4 Hz, indicating issues with the ionization signal or the printed circuit. It is compatible with several models from the Junkers Euroline range, such as the ZW23-1KE31 and the ZS23-1AE31, among others. A technician must confirm through diagnosis whether it is necessary to replace it when these symptoms or faults in operation are detected.

Catalogue reference
87083002120
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Junkers boilers compatible with reference 87083002120

PCB with reference 87083002120. 22 verified compatibilities: ZW23-1AE23 and ZW23-1AE31.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZW23-1AE23Junkers Euroline ZW (combi)Contrasted
Junkers ZW23-1AE31Junkers Euroline ZW (combi)Contrasted
Junkers ZW23-1KE23Junkers Euroline ZW (combi)Contrasted
Junkers ZW23-1KE31Junkers Euroline ZW (combi)Contrasted
Junkers ZW24-1ELH AE23Junkers Euroline ZW (combi)Contrasted
Junkers ZW24-1ELH AE31Junkers Euroline ZW (combi)Contrasted
Junkers ZW28-1LHKE23Junkers Euroline ZW (combi)Contrasted
Junkers ZW28-1LHKE31Junkers Euroline ZW (combi)Contrasted
Junkers ZW30-1LHAE23Junkers Euroline ZW (combi)Contrasted
Junkers ZW30-1LHAE31Junkers Euroline ZW (combi)Contrasted
Junkers ZS23-1AE23Junkers Euroline ZS (heating only)Contrasted
Junkers ZS23-1AE31Junkers Euroline ZS (heating only)Contrasted
Junkers ZS23-1KE23Junkers Euroline ZS (heating only)Contrasted
Junkers ZS23-1KE31Junkers Euroline ZS (heating only)Contrasted
Junkers NW24-1LHAE23Junkers Euroline NW24Contrasted
Junkers NW24-1LHAE31Junkers Euroline NW24Contrasted
Junkers NW24-1LHKE23Junkers Euroline NW24Contrasted
Junkers NW24-1LHKE31Junkers Euroline NW24Contrasted
Junkers NW24/28-1LHKE23Junkers Euroline NW24Contrasted
Junkers NW24/28-1LHKE31Junkers Euroline NW24Contrasted
Junkers NW24/30-1LHAE23Junkers Euroline NW24Contrasted
Junkers NW24/30-1LHAE31Junkers Euroline NW24Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87083002120 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87083002120. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 87083002120

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not turn on and there are no indicator lights on the panel.

    Cause: There is no power reaching the PCB, so the other components cannot start.

    Check the fuse on the PCB and the power supply before assuming that the board is faulty.

  • 02

    An intermittent fault code appears that disappears and then reappears.

    Cause: The PCB responds to sensor readings; an internal fault can cause erratic readings.

    Record the code each time it appears and compare it with the fault code table; if it always matches the same sensor, test that component first.

  • 03

    The flame ignites but cuts off after a few seconds and the boiler locks out.

    Cause: The PCB controls the flame and safety signal; if its circuit fails, it interprets a fault even if the burner is operating.

    Check the ionization electrode and its wiring before replacing the PCB, as it is the most common cause of this symptom.

  • 04

    The digital control remains frozen or does not change screens.

    Cause: The microcontroller on the PCB manages communication with the display; if it gets damaged, the remote control stops working.

    Turn the boiler off and on from the main switch to rule out a temporary freeze before replacing the PCB.

Junkers fault codes that require diagnosis

CodeFaultTechnical checks
Reset button flashing 0.5 Hz + LED 75 °CDuring ignition: ionisation signal is detected but the burner does not ignite.The printed circuit board (PCB 87083002120) may fail in the detection/ionisation path or be damp, causing false flame or lack of spark; check ionisation microamperage, wiring, and moisture/oxidation on the PCB before replacing it.
Reset button flashes at 4 Hz (four times per second)Control/safety fault (encoder/sensors) including possible PCB defect.Fault in the PCB (Eurotronic/PCB) in managing inputs/power supplies; check voltages at ST2 (L–N/LR–N), fuses F1/F2, and 5 V to sensors. If everything is correct and the symptom persists, replace the 87083002120.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers 87083002120 PCB.

Catalogue reference
87083002120
Uniclima internal SKU
PLBO069
Brand
Junkers
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer of the PCB (silkscreen)
Honeywell
PCB code
45.007.351-005 REV.P
Voltage
230VAC
Frequency
50Hz
Power
10VA
Manufacturing date (of the photographed unit)
SEP-2005
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 87083002120

Which models are compatible with the Honeywell Junkers Euroline ZW23 1KE31 Bosch PCB Ref. 87083002120?
The PCB is compatible with 22 models from the Junkers Euroline ZW, ZS, and NW24 ranges, such as ZW23-1KE31, ZS23-1AE31, and NW24-1LHAE31, among others.
Who manufactures the Honeywell PCB for the Junkers Euroline?
The PCB is manufactured by Honeywell, according to the silkscreen on the board itself.
What is the exact code for this Honeywell PCB for Junkers Euroline?
The code is 45.007.351-005 REV.P, which can be found on the label of the PCB.
What power supply does the PCB for the Junkers Euroline need?
The PCB requires a power supply of 230VAC at 50Hz, with a consumption of 10VA, according to the label.
Is this PCB compatible with any Junkers Euroline model?
No, the PCB is only compatible with the specific models listed in the compatibility chart of this document.
What is the reference for the Honeywell PCB for Junkers Euroline?
PLBO069 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.

Spare parts related to Junkers Euroline ZW (combi)

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Honeywell PCB Junkers Euroline ZW23 1KE31 Bosch Ref. 87083002120