PCB Boiler ZWB28-3C23 Ref. 8748300941

PCB Boiler ZWB28-3C23 Ref. 8748300941

Stock · 2 units

The PCB for the ZWB28-3C23 Ref. 8748300941 boiler from Junkers controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, lock out, or behave erratically, which can lead to faults such as F0, EA, C6, or A7. This part is compatible with models like ZWB28-3C23, ZWB28-3C31, ZWB28-3CE23, among others from the Junkers Cerapur Smart range, as well as some from the Neckar NWB24-3C series. It is recommended to replace it when the mentioned symptoms occur or if the associated faults are detected.

VAT included

Compatibility

Junkers boilers compatible with reference 8748300941

PCB with reference 8748300941. Six confirmed compatibilities: ZWB28-3C23 and ZWB28-3C31.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWB28-3C23Junkers Cerapur Smart ZWB28-3CContrasted
Junkers ZWB28-3C31Junkers Cerapur Smart ZWB28-3CContrasted
Junkers ZWB28-3CE23Junkers Cerapur Smart ZWB28-3CContrasted
Junkers ZWB28-3CE31Junkers Cerapur Smart ZWB28-3CContrasted
Junkers NWB24-3C23Neckar NWB24-3CContrasted
Junkers NWB24-3CE23Neckar NWB24-3CContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 8748300941 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 8748300941. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 8748300941 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The display shows a fixed fault code that cannot be reset.

    Cause: The PCB generates and maintains that code; if its electronics fail, the code persists even if there is no real problem.

    Note the code and compare it with the fault list of your boiler; some codes indicate problems with the sensor or pressure, not with the PCB.

  • 02

    The boiler does not ignite at all, neither heating nor hot water, and the display is off or very dim.

    Cause: If the PCB does not properly power the circuit, no component can be activated.

    Check that power is reaching the boiler and verify that the fuse on the PCB is not blown.

  • 03

    The pump, the fan, or the gas valve activate by themselves, without a demand for heat.

    Cause: The PCB controls the output relays; if any of them fail or get stuck, the component operates without a real command.

    Disconnect that component and check if it continues to work: if it stops, the problem may be with it and not with the PCB.

  • 04

    The boiler starts up well but resets itself every few minutes.

    Cause: An intermittent fault on the PCB can restart the control cycle without a real thermal reason.

    Check that the connection box and the connectors on the PCB do not have any play or corrosion before replacing it.

Fault codes from Junkers that this part resolves.

CodeFaultDiagnosis and solution
F0Incorrect reference voltage (internal electronics error).The PCB (Heatronic/"control unit") may lose internal references or fail; check service parameters (8.d/8.C), wiring, and if it persists after resets and checks, replace the PCB.
EAFlame not detected during ignition.If gas, electrodes, and wiring are correct and the ionisation current is low/erratic, an electronic fault in the PCB (ignition/ionisation reading) may prevent flame detection; measure ionisation µA and, if after the diagnostic tree it persists, replace the PCB.
C6The fan does not start / fan fault/airflow.After checking the connector, power supply, and fan, the manual indicates "electronic fault" and change of PCB; also in Bosch documentation, it is advised to check connections on the PCB and, if necessary, replace the 'control board'.
A7Defective DHW NTC sensor.If the NTC and the harness ('baum') measure correctly even from the 20-pin connector, the reading circuit on the PCB itself may be faulty; measure the NTC at the sensor and on the PCB, and if there is an 'electronic fault', replace the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers 8748300941 PCB.

Catalogue reference
8748300941
Brand
Junkers
Type of part
PCBs (control boards)
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

voltage
AC 230V
frequency
50Hz
Frequently Asked Questions

Frequently asked questions about the PCB 8748300941

Is this PCB suitable for a ZWB28-3C23 boiler?
Yes, the ZWB28-3C23 is on the list of compatible boilers from the series 3 (versions C and CE).
Is it also suitable for a ZSB14-3CE23?
Yes, the ZSB14-3CE23 is among the eight ZSB/ZWB models from the series 3 that are compatible with this PCB.

Spare parts related to Junkers Junkers Cerapur Smart ZWB28-3C

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
PCB Boiler ZWB28-3C23 Ref. 8748300941