Biasi and Savio Gaia Plate Heat Exchanger - Ref. BI1001102

Biasi and Savio Gaia Plate Heat Exchanger - Ref. BI1001102

Stock · 4 units

If you notice that the domestic hot water is lukewarm or has fluctuating temperatures, you may need the Biasi and Savio Gaia plate heat exchanger - Ref. BI1001102. This part transfers heat from the primary circuit to the hot water instantly, and its failure can lead to a decrease in the flow of DHW. It is compatible with boilers such as the Biasi Garda HE M96, Biasi Garda M90E/M90F, Biasi Prisma, Biasi Riva Compact, and Savio Gaia, among others. It is recommended to replace it when these symptoms of unstable temperature or low flow occur.

VAT included

Compatibility

Biasi boilers compatible with reference BI1001102

Plate heat exchanger with reference BI1001102. Ten verified compatibilities: Garda HE M96.24 SM and Garda HE M96.28 SM.

Proven compatibility

Boiler modelFamilyVerification
Biasi Garda HE M96.24 SMBiasi Garda HE M96 (combi)Contrasted
Biasi Garda HE M96.28 SMBiasi Garda HE M96 (combi)Contrasted
Biasi Garda M90F.28SBiasi Garda M90E / M90F (combi)Contrasted
Biasi Garda M90F.32SBiasi Garda M90E / M90F (combi)Contrasted
Biasi Garda M90E.28SBiasi Garda M90E / M90F (combi)Contrasted
Biasi Prisma 28SBiasi PrismaContrasted
Biasi Prisma 28SEBiasi PrismaContrasted
Biasi Riva Compact M90E.28SBiasi Riva Compact (M90E / M96)Contrasted
Biasi Riva Compact HE M96.28 SMBiasi Riva Compact (M90E / M96)Contrasted
Biasi Gaia 428SSavio GaiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference BI1001102 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference BI1001102. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the heat exchanger BI1001102 resolves

The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The hot water comes out lukewarm or loses pressure within a few seconds, even when the tap is fully open.

    Cause: Limescale builds up between the plates of the heat exchanger and blocks the flow of water, preventing the boiler from transferring all the heat.

    Measure the hardness of the water in your area and check if the boiler has not been descaled for a long time; a descaling can improve performance without the need to replace the part.

  • 02

    There is a drip or a puddle of water right under the boiler, without a clear indication of where it is coming from.

    Cause: When the heat exchanger loses tightness between plates, water escapes through the joint or through a microcrack in the body.

    Dry the area well, turn on the boiler, and use a flashlight to check if the dripping comes from the body of the heat exchanger or from a nearby fitting or bleed valve.

  • 03

    The heating circuit needs to be filled every few days, and the pressure gauge rises just when you request hot water.

    Cause: An internal crack in the heat exchanger allows water from one circuit to pass to the other, mixing domestic hot water and heating.

    Note if the pressure rises when opening a hot water tap; if this occurs repeatedly, it is a clear indication of mixing between circuits.

  • 04

    The hot water takes longer than usual to come out, or it comes out in intervals, as if it cuts off and then comes back.

    Cause: A partially clogged heat exchanger allows water to flow irregularly instead of at a constant rate.

    Check if the cold water inlet filter is dirty or calcified, because sometimes the problem lies there and not in the heat exchanger.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Biasi BI1001102 plate heat exchanger.

Catalogue reference
BI1001102
Brand
Biasi
Type of part
Plate heat exchanger
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Frequently Asked Questions

Frequently asked questions about the plate heat exchanger BI1001102

Is this plate heat exchanger compatible with the Biasi Prisma 28SE?
Yes, the Biasi and Savio Gaia plate heat exchanger – Ref. BI1001102 is compatible with the Biasi Prisma 28SE, which is on the list of confirmed models.
How many models are compatible with this heat exchanger?
The Biasi and Savio Gaia plate heat exchanger – Ref. BI1001102 is compatible with a total of 10 models.
Does the heat exchanger include O-rings or screws?
The photos show screws and O-rings from the kit on the connection face, but there is no further technical confirmation regarding this.
Is the reference for this heat exchanger IPBM9524?
Yes, the reference for the plate heat exchanger is IPBM9524.
Does this heat exchanger work for the Biasi Garda HE M96.28 SM?
Yes, the plate heat exchanger is compatible with the Biasi Garda HE M96.28 SM, which is on the list of confirmed models.

Spare parts related to Biasi Biasi Garda M90E / M90F (combi)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Biasi and Savio Gaia Plate Heat Exchanger - Ref. BI1001102