
Biasi and Savio Gaia Plate Heat Exchanger - Ref. BI1001102
If you notice that the domestic hot water is lukewarm or has fluctuating temperatures, you may need the Biasi and Savio Gaia plate heat exchanger - Ref. BI1001102. This part transfers heat from the primary circuit to the hot water instantly, and its failure can lead to a decrease in the flow of DHW. It is compatible with boilers such as the Biasi Garda HE M96, Biasi Garda M90E/M90F, Biasi Prisma, Biasi Riva Compact, and Savio Gaia, among others. It is recommended to replace it when these symptoms of unstable temperature or low flow occur.
VAT included
Consult via WhatsAppBiasi boilers compatible with reference BI1001102
Plate heat exchanger with reference BI1001102. Ten verified compatibilities: Garda HE M96.24 SM and Garda HE M96.28 SM.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Garda HE M96.24 SM | Biasi Garda HE M96 (combi) | Contrasted |
| Biasi Garda HE M96.28 SM | Biasi Garda HE M96 (combi) | Contrasted |
| Biasi Garda M90F.28S | Biasi Garda M90E / M90F (combi) | Contrasted |
| Biasi Garda M90F.32S | Biasi Garda M90E / M90F (combi) | Contrasted |
| Biasi Garda M90E.28S | Biasi Garda M90E / M90F (combi) | Contrasted |
| Biasi Prisma 28S | Biasi Prisma | Contrasted |
| Biasi Prisma 28SE | Biasi Prisma | Contrasted |
| Biasi Riva Compact M90E.28S | Biasi Riva Compact (M90E / M96) | Contrasted |
| Biasi Riva Compact HE M96.28 SM | Biasi Riva Compact (M90E / M96) | Contrasted |
| Biasi Gaia 428S | Savio Gaia | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference BI1001102 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI1001102. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the heat exchanger BI1001102 resolves
The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The hot water comes out lukewarm or loses pressure within a few seconds, even when the tap is fully open.
Cause: Limescale builds up between the plates of the heat exchanger and blocks the flow of water, preventing the boiler from transferring all the heat.
Measure the hardness of the water in your area and check if the boiler has not been descaled for a long time; a descaling can improve performance without the need to replace the part.
- 02
There is a drip or a puddle of water right under the boiler, without a clear indication of where it is coming from.
Cause: When the heat exchanger loses tightness between plates, water escapes through the joint or through a microcrack in the body.
Dry the area well, turn on the boiler, and use a flashlight to check if the dripping comes from the body of the heat exchanger or from a nearby fitting or bleed valve.
- 03
The heating circuit needs to be filled every few days, and the pressure gauge rises just when you request hot water.
Cause: An internal crack in the heat exchanger allows water from one circuit to pass to the other, mixing domestic hot water and heating.
Note if the pressure rises when opening a hot water tap; if this occurs repeatedly, it is a clear indication of mixing between circuits.
- 04
The hot water takes longer than usual to come out, or it comes out in intervals, as if it cuts off and then comes back.
Cause: A partially clogged heat exchanger allows water to flow irregularly instead of at a constant rate.
Check if the cold water inlet filter is dirty or calcified, because sometimes the problem lies there and not in the heat exchanger.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Biasi BI1001102 plate heat exchanger.
- Catalogue reference
- BI1001102
- Brand
- Biasi
- Type of part
- Plate heat exchanger
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days












