Pressure Gauge 0-4 Bar for Boiler ZWC/ZC 24-1 and 28-1 MFA

Pressure Gauge 0-4 Bar for Boiler ZWC/ZC 24-1 and 28-1 MFA

Stock · 1 unit

The Junkers Euromaxx ZWC/ZC boilers use a 0-4 bar pressure gauge, a component that measures and controls the water circuit pressure. If the pressure gauge fails, you will notice incorrect readings, which can cause the boiler to lock out due to a false low pressure or not regulate the temperature properly. This pressure gauge is compatible with models such as ZC 24-1 MFA, ZC 28-1 MFA, ZWC 24-1 MFA, among others. It is recommended to replace it when the readings are unreliable or when the boiler shows operational issues related to pressure.

VAT included

Compatibility

Junkers boilers compatible with reference 8716771600

Pressure gauge with reference 8716771600. 15 verified compatibilities: ZC 24-1 MFA and ZC 28-1 MFA.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZC 24-1 MFAJunkers Euromaxx ZCContrasted
Junkers ZC 28-1 MFAJunkers Euromaxx ZCContrasted
Junkers ZC 24-1 MFKJunkers Euromaxx ZCContrasted
Junkers ZC 28-1 MFKJunkers Euromaxx ZCContrasted
Junkers ZWC 24-1 MFAJunkers Euromaxx ZWCContrasted
Junkers ZWC 28-1 MFAJunkers Euromaxx ZWCContrasted
Junkers ZWC 24-1 MFKJunkers Euromaxx ZWCContrasted
Junkers ZWC 28-1 MFKJunkers Euromaxx ZWCContrasted
Junkers ZWC 24-1 MF2AJunkers Euromaxx ZWCContrasted
Junkers ZWC 28-1 MF2AJunkers Euromaxx ZWCContrasted
Junkers ZWC 24-1 MF2KJunkers Euromaxx ZWCContrasted
Junkers ZWC 28-1 MF2KJunkers Euromaxx ZWCContrasted
Junkers ZWC 24-1/3 MFAJunkers Euromaxx ZWCContrasted
Junkers ZWC 28-1/3 MFAJunkers Euromaxx ZWCContrasted
Junkers ZWC 28/32-1 MFAJunkers Euromaxx ZWCContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 8716771600 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 8716771600. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure gauge 8716771600 resolves.

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The yellow needle does not move, whether you open the filling tap or bleed a radiator.

    Cause: The internal mechanism has seized and lost the ability to follow the pressure changes in the circuit.

    Try bleeding and refilling water while observing the needle in real-time; if it doesn't react at any point, the part is not transmitting the pressure.

  • 02

    The boiler operates normally, but the pressure gauge continuously moves out of the green zone.

    Cause: The sensor element has become uncalibrated and no longer accurately reflects the actual pressure, even though the circuit is fine.

    Check that there are no visible leaks in radiators or bleed valves before relying solely on the pressure gauge reading.

  • 03

    You notice that you have to refill the boiler with water very often because the pressure gauge always shows low pressure.

    Cause: If the reading continuously drops even after refilling, the pressure gauge might be giving a false reading below the actual one.

    Mark the level after refueling and monitor if it drops within hours without any visible leaks in the installation; if it only drops on the pressure gauge and there's no water on the floor, suspect the part.

  • 04

    Water is dripping right where the pressure gauge connects to the boiler.

    Cause: The sealing gasket of the connection has degraded and is allowing water to pass through the thread.

    Dry the area and tighten the connection carefully without forcing it; if the dripping persists after tightening, the internal gasket is deteriorated.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Junkers 8716771600 pressure gauge datasheet

Catalogue reference
8716771600
Brand
Junkers
Type of part
Pressure gauges & aquastats
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Pressure gauge
0-4 bar
Green zone (recommended range)
1-2 bar
Dial color
White
Needle color
Yellow
Frequently Asked Questions

Frequently asked questions about the pressure gauge 8716771600

Is this white dial pressure gauge suitable for the ZWC 24-1 MFA?
Yes, the ZWC 24-1 MFA is on the list of compatible boilers for this part.
What pressure should this pressure gauge indicate on the ZC 28-1 MFA when it is at rest?
Between 1 and 2 bar, the green zone marked on the dial.
When should this pressure gauge for the ZWC 28-1 MFK be replaced?
When the needle doesn't move, consistently indicates outside the green zone, or there is a leak at its connection.
Is this pressure gauge also suitable for the ZWC 28-1/3 MFA?
Yes, the ZWC 28-1/3 MFA is listed as a compatible boiler in this datasheet.