Pressure Sensor Saunier Duval Themafast C 30 E - Cod. 0020016532

Pressure Sensor Saunier Duval Themafast C 30 E - Cod. 0020016532

Stock · 5 units

Saunier Duval Themafast C 30 E includes the pressure sensor Cod. 0020016532, which measures the water pressure in the circuit and sends this information to the control board. If it fails, it can cause incorrect readings, lockouts, and faults such as F9, F.73, F.74, or F.75. This component is compatible with several models from the Isofast, Isomax, Isotwin, Themaplus, Themafast, Themaclassic, and Themacondens ranges, among others. It is advisable to replace it when the mentioned symptoms are detected or if recurrent lockouts occur in the boiler.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S57205

Pressure sensor with reference S57205. 41 verified compatibilities: C24EV and C28E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval C24EVIsofastContrasted
Saunier Duval C28EIsofastContrasted
Saunier Duval C28E1IsofastContrasted
Saunier Duval C35EIsofastContrasted
Saunier Duval C35E1IsofastContrasted
Saunier Duval F24EIsofastContrasted
Saunier Duval F28EIsofastContrasted
Saunier Duval F28E1IsofastContrasted
Saunier Duval F35EIsofastContrasted
Saunier Duval F35E1IsofastContrasted
Saunier Duval C28EIsomaxContrasted
Saunier Duval C28E2IsomaxContrasted
Saunier Duval F28EIsomaxContrasted
Saunier Duval F28E2IsomaxContrasted
Saunier Duval Condens F35EIsomaxContrasted
Saunier Duval C24EIsotwinContrasted
Saunier Duval F24EIsotwinContrasted
Saunier Duval F28EIsotwinContrasted
Saunier Duval Condens F30-AIsotwinContrasted
Saunier Duval C24EThemaplusContrasted
Saunier Duval F24EThemaplusContrasted
Saunier Duval F25EThemaplusContrasted
Saunier Duval F30EThemaplusContrasted
Saunier Duval C24EThemafastContrasted
Saunier Duval F24EThemafastContrasted
Saunier Duval Condens F24EThemafastContrasted
Saunier Duval Condens F30EThemafastContrasted
Saunier Duval F24EThemaclassicContrasted
Saunier Duval F25EThemaclassicContrasted
Saunier Duval C24EThemaclassicContrasted
Saunier Duval FAS24EThemaclassicContrasted
Saunier Duval FAS25EThemaclassicContrasted
Saunier Duval F24EThemacondensContrasted
Saunier Duval F25ThemacondensContrasted
Saunier Duval FAS25ThemacondensContrasted
Saunier Duval C18EThematekContrasted
Saunier Duval C24EThematekContrasted
Saunier Duval F24EThematekContrasted
Saunier Duval C24EThemaContrasted
Saunier Duval Condens F25ThemaContrasted
Saunier Duval Condens F25SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S57205 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S57205. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch S57205 resolves.

The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The digital manometer of the boiler is stuck at a value and does not change even if you bleed or refill water.

    Cause: The sensor has stopped sending pressure variations to the PCB, and it continues to display the last valid reading.

    Fill or bleed the circuit while observing if the digital value changes; if it does not react in any way, the sensor is not transmitting.

  • 02

    A low water pressure warning appears and the boiler stops providing heating.

    Cause: The PCB cuts off the service for safety when the signal from the sensor falls below the programmed minimum threshold.

    First, check the actual pressure by filling it to 1-1.5 bar when cold; if the warning persists with the correct pressure, suspect the sensor.

  • 03

    The boiler does not start and there is no pressure value on the display, neither high nor low.

    Cause: Without input signal from the sensor, the control unit has nothing to compare and blocks the start as a safety measure.

    Check that the wiring of the sensor is not disconnected or frayed in the section up to the PCB before replacing it.

  • 04

    The pressure reading suddenly jumps between very different values without any changes being made to the circuit.

    Cause: It is typical of a collector with a degraded internal sensor to give erratic readings unrelated to the actual pressure.

    Check if the jump coincides with vibrations or impacts in the nearby pipe; if not, the fault is with the sensor itself.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F9Water pressure sensor fault.The S57205 sensor does not deliver a valid signal (loose connector, short circuit, or obstructed hydraulic connection) and the PCB does not 'see' pressure; check wiring and pressure reading in diagnostic/menu and verify that the signal changes when pressurizing.
F.73Water pressure sensor signal out of range (too low).Interruption/short circuit of the sensor or ground in the cable; check power supply and sensor signal, continuity of the harness, and ensure the sensor port is not blocked.
F.74Water pressure sensor signal out of range (usually too high).Short circuit at 5/24 V or internal fault of the sensor; measure the sensor output and check if it remains fixed at high; inspect wiring and clean the orifice, replacing the sensor if it does not recover.
F.75No increase in pressure detected when the pump starts (pressure sensor and/or pump).The sensor does not detect the pressure 'spike' due to a faulty sensor or blocked intake (first rule out air/lack of water/pump); check the pressure reading during start-up in service mode and the continuity/power supply of the sensor.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for Saunier Duval pressure sensor S57205

Catalogue reference
S57205
Brand
Saunier Duval
Type of part
Pressure sensors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Code on label
0020016532
Batch number
0702192 DD
Frequently Asked Questions

Frequently asked questions about the pressure sensor S57205

When should this sensor be replaced in the Isotwin C 24 EA?
When the digital manometer shows a pressure error or stops providing a correct reading.
Is this sensor suitable for the Saunier Duval Themaclassic F 25 E?
Yes, the Themaclassic F 25 E is on the list of boilers compatible with this part.