
Pressure Sensor Saunier Duval Themafast C 30 E - Cod. 0020016532
Saunier Duval Themafast C 30 E includes the pressure sensor Cod. 0020016532, which measures the water pressure in the circuit and sends this information to the control board. If it fails, it can cause incorrect readings, lockouts, and faults such as F9, F.73, F.74, or F.75. This component is compatible with several models from the Isofast, Isomax, Isotwin, Themaplus, Themafast, Themaclassic, and Themacondens ranges, among others. It is advisable to replace it when the mentioned symptoms are detected or if recurrent lockouts occur in the boiler.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S57205
Pressure sensor with reference S57205. 41 verified compatibilities: C24EV and C28E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval C24EV | Isofast | Contrasted |
| Saunier Duval C28E | Isofast | Contrasted |
| Saunier Duval C28E1 | Isofast | Contrasted |
| Saunier Duval C35E | Isofast | Contrasted |
| Saunier Duval C35E1 | Isofast | Contrasted |
| Saunier Duval F24E | Isofast | Contrasted |
| Saunier Duval F28E | Isofast | Contrasted |
| Saunier Duval F28E1 | Isofast | Contrasted |
| Saunier Duval F35E | Isofast | Contrasted |
| Saunier Duval F35E1 | Isofast | Contrasted |
| Saunier Duval C28E | Isomax | Contrasted |
| Saunier Duval C28E2 | Isomax | Contrasted |
| Saunier Duval F28E | Isomax | Contrasted |
| Saunier Duval F28E2 | Isomax | Contrasted |
| Saunier Duval Condens F35E | Isomax | Contrasted |
| Saunier Duval C24E | Isotwin | Contrasted |
| Saunier Duval F24E | Isotwin | Contrasted |
| Saunier Duval F28E | Isotwin | Contrasted |
| Saunier Duval Condens F30-A | Isotwin | Contrasted |
| Saunier Duval C24E | Themaplus | Contrasted |
| Saunier Duval F24E | Themaplus | Contrasted |
| Saunier Duval F25E | Themaplus | Contrasted |
| Saunier Duval F30E | Themaplus | Contrasted |
| Saunier Duval C24E | Themafast | Contrasted |
| Saunier Duval F24E | Themafast | Contrasted |
| Saunier Duval Condens F24E | Themafast | Contrasted |
| Saunier Duval Condens F30E | Themafast | Contrasted |
| Saunier Duval F24E | Themaclassic | Contrasted |
| Saunier Duval F25E | Themaclassic | Contrasted |
| Saunier Duval C24E | Themaclassic | Contrasted |
| Saunier Duval FAS24E | Themaclassic | Contrasted |
| Saunier Duval FAS25E | Themaclassic | Contrasted |
| Saunier Duval F24E | Themacondens | Contrasted |
| Saunier Duval F25 | Themacondens | Contrasted |
| Saunier Duval FAS25 | Themacondens | Contrasted |
| Saunier Duval C18E | Thematek | Contrasted |
| Saunier Duval C24E | Thematek | Contrasted |
| Saunier Duval F24E | Thematek | Contrasted |
| Saunier Duval C24E | Thema | Contrasted |
| Saunier Duval Condens F25 | Thema | Contrasted |
| Saunier Duval Condens F25 | Semia | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S57205 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S57205. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch S57205 resolves.
The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The digital manometer of the boiler is stuck at a value and does not change even if you bleed or refill water.
Cause: The sensor has stopped sending pressure variations to the PCB, and it continues to display the last valid reading.
Fill or bleed the circuit while observing if the digital value changes; if it does not react in any way, the sensor is not transmitting.
- 02
A low water pressure warning appears and the boiler stops providing heating.
Cause: The PCB cuts off the service for safety when the signal from the sensor falls below the programmed minimum threshold.
First, check the actual pressure by filling it to 1-1.5 bar when cold; if the warning persists with the correct pressure, suspect the sensor.
- 03
The boiler does not start and there is no pressure value on the display, neither high nor low.
Cause: Without input signal from the sensor, the control unit has nothing to compare and blocks the start as a safety measure.
Check that the wiring of the sensor is not disconnected or frayed in the section up to the PCB before replacing it.
- 04
The pressure reading suddenly jumps between very different values without any changes being made to the circuit.
Cause: It is typical of a collector with a degraded internal sensor to give erratic readings unrelated to the actual pressure.
Check if the jump coincides with vibrations or impacts in the nearby pipe; if not, the fault is with the sensor itself.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F9 | Water pressure sensor fault. | The S57205 sensor does not deliver a valid signal (loose connector, short circuit, or obstructed hydraulic connection) and the PCB does not 'see' pressure; check wiring and pressure reading in diagnostic/menu and verify that the signal changes when pressurizing. |
| F.73 | Water pressure sensor signal out of range (too low). | Interruption/short circuit of the sensor or ground in the cable; check power supply and sensor signal, continuity of the harness, and ensure the sensor port is not blocked. |
| F.74 | Water pressure sensor signal out of range (usually too high). | Short circuit at 5/24 V or internal fault of the sensor; measure the sensor output and check if it remains fixed at high; inspect wiring and clean the orifice, replacing the sensor if it does not recover. |
| F.75 | No increase in pressure detected when the pump starts (pressure sensor and/or pump). | The sensor does not detect the pressure 'spike' due to a faulty sensor or blocked intake (first rule out air/lack of water/pump); check the pressure reading during start-up in service mode and the continuity/power supply of the sensor. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for Saunier Duval pressure sensor S57205
- Catalogue reference
- S57205
- Brand
- Saunier Duval
- Type of part
- Pressure sensors
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Code on label
- 0020016532
- Batch number
- 0702192 DD












