Vaillant 3 Bar Safety Valve (DN15, ref. 190732)

Vaillant 3 Bar Safety Valve (DN15, ref. 190732)

15 €VAT includedTemporarily out of stock

Safety valve set at 3 bar, with DN15 connection, for Vaillant boilers from the VM, VMI, VMW, VUI, VUW, VKC, and AquaPlus series, among the indicated compatible models. It releases pressure from the heating circuit when the set limit is exceeded, protecting the heat exchanger from overpressure. It should be replaced when it continuously drips or fails to activate upon reaching the set pressure.

Spare parts related to Vaillant Acquablock (VMI)

Compatibility

Vaillant boilers compatible with reference 190732

Safety valve with reference 190732. Nine confirmed compatibilities with two independent sources: VMI 280-7 and VMI 282-7. Verify the printed reference on your part before purchasing.

Compatibility confirmed

Boiler modelFamilyVerification
Vaillant VMI 280-7Acquablock (VMI)Confirmed · 2 sources
Vaillant VMI 282-7Acquablock (VMI)Confirmed · 2 sources
Vaillant VMI 280-7 R3Acquablock (VMI)Confirmed · 2 sources
Vaillant VMI 282-7 R2Acquablock (VMI)Confirmed · 2 sources
Vaillant VMW 275/3-7Turbotec / Atmotec (VMW)Confirmed · 2 sources
Vaillant VMW 242/2-3Turbotec / Atmotec (VMW)Confirmed · 2 sources
Vaillant VMW 242Turbotec / Atmotec (VMW)Confirmed · 2 sources
Vaillant VMW 280VM / VMW (Atmoblock / Turboblock)Confirmed · 2 sources
Vaillant VMW 282VM / VMW (Atmoblock / Turboblock)Confirmed · 2 sources

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 190732 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Locate the reference printed on the body of the safety valve you have installed: it should indicate 190732.
  2. Check your boiler model on the nameplate and look for it in the list of compatible models on this page.
  3. Compare the connections and the body with the original part before installing.
  4. If you have any doubts, send us a photo of the screen printing via WhatsApp and we'll confirm it for you before you purchase.
Diagnosis

Symptoms and faults resolved by safety valve 190732

The safety valve releases pressure when the circuit exceeds its set point. These are the typical symptoms and what to do:

The valve is continuously leaking through the discharge pipe.

Cause: The seat doesn't close properly, usually due to lime or dirt lodged in the mechanism.

Check the cold pressure of the circuit; if it is already above normal at rest, first inspect the filling and the expansion vessel.

The valve does not activate when the circuit reaches high pressure.

Cause: The mechanism may be seized due to lack of use, leaving the heat exchanger without real protection against overpressure.

Operate the test lever with the boiler cold to check if it bleeds water before replacing it.

The valve activates either well before the pressure reaches high levels or much later than expected.

Cause: If the trip does not match what the pressure gauge indicates, the internal calibration mechanism has lost precision.

Compare the pressure indicated by the manometer at the moment of the trip in several tests before concluding that it has lost calibration.

The circuit loses pressure and no visible leak appears in radiators or pipes.

Cause: The water is being bled through the discharge pipe of the valve, without leaving any visible trace.

Check the outlet of the discharge pipe for any lime deposits or recent moisture before inspecting other areas of the circuit.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for Vaillant safety valve 190732

OEM reference
190732
Brand
Vaillant
Type of part
Safety Valves
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Connection
DN15
label
Setpoint
3 bar
label
Approval code
TÜV·SV·13-1089-H-60
label
Before purchasing
  • The actual manufacturer of the part is not listed. On the body, there is a logo (a stylized hare or rabbit head inside a rectangle) that could not be identified with a specific brand.
  • Check that the TÜV·SV·13-1089-H-60 approval code matches your part before ordering it.
Frequently Asked Questions

Frequently Asked Questions about Safety Valve 190732

Is this 3 bar safety valve suitable for a Vaillant VMW 242?
Yes, the Vaillant VMW 242 is on the list of boilers compatible with reference 190732.
Who manufactures the safety valve Ref. 190732 for Vaillant?
The manufacturer is not listed on the part; it only has an unidentified logo (a hare or rabbit head) and the approval code TÜV·SV·13-1089-H-60.
What fault does this 3 bar DN15 safety valve resolve in a Vaillant boiler?
Releases pressure from the heating circuit when the set limit is exceeded, protecting the heat exchanger from overpressure.
When should this valve be replaced in a Vaillant VM 280?
When it drips continuously or when it doesn't activate upon reaching the set pressure of 3 bar.
How do I check if this valve is the one for my Vaillant VUW Turbomax?
Verify that the connection is DN15 and the setting is 3 bar, and that your model is among the VM, VMI, VMW, VUI, VUW, VKC, or AquaPlus series indicated as compatible.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model