Brahma PCB Sime Format 25/60 BF Code 16020798
RefurbishedSimePCBs (control boards)Brahma

Brahma PCB Sime Format 25/60 BF Code 16020798

VAT includedStock · 1 unit

Electronic component manufactured by Brahma, identified by the code 16020798 and model 351.7F002, with a manufacturing date of 09-12. It operates at 230V and 50-60Hz. It is installed in Sime boilers from the Format, Format ZIP, Metro, and Planet Dewy series. Replacement requires first confirming the fault of the component through technical diagnosis, even when the original module with the same codes fails or stops functioning.

Compatibility

Sime boilers compatible with reference 6230687

PCB with reference 6230687. Five confirmed compatibilities: Format 25/60 BF and Format 30/60 BF.

Proven compatibility

Boiler modelFamilyVerification
Sime Format 25/60 BFSime FormatContrasted
Sime Format 30/60 BFSime FormatContrasted
Sime Format 25/60 OFSime FormatContrasted
Sime Format ZIP 25 BFSime FormatContrasted
Sime Metro 25 BFSime MetroContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 6230687 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 6230687. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 6230687

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start at all, with no sign of activity.

    Cause: The Brahma PCB powers and coordinates the rest of the components; if its input stage fails, none of the equipment responds.

    Check with a tester that the PCB is receiving the 230V indicated on its label before replacing it; without input voltage, any PCB will remain silent.

  • 02

    A fault code appears and the boiler does not continue the ignition cycle.

    Cause: The PCB aborts the sequence when any safety signal is not as expected, whether the fault is its own or from a connected sensor.

    Note the code and compare it with the equipment manual before purchasing; some codes are resolved by checking a sensor, not the PCB.

  • 03

    The control or the room thermostat is not able to start the boiler.

    Cause: The PCB input that receives the heating demand may become inoperative even if the rest of the system is functioning.

    Check the thermostat wiring on the PCB terminal block and ensure it is properly bridged before discarding it.

  • 04

    The pump or the gas valve remain without command even though the boiler is requesting heat.

    Cause: The corresponding output relay on the PCB can fail in isolation, without affecting the rest of the functions.

    Measure with a tester if there is voltage going to the pump or valve connector when it should; if not, it points to the PCB.

  • 05

    The boiler intermittently shuts off on its own, especially after it has been running for a while.

    Cause: A component of the PCB that degrades with heat can cause interruptions that only appear after a period of use.

    Check if the shutdown always occurs after the same operating time; this thermal pattern is typical of a fault in the PCB.

Sime fault codes that require diagnosis

CodeFaultTechnical checks
Red LED lockout ignition/safety thermostat interventionLockout due to ignition fault or intervention of the safety thermostat.In these models, the PCB (board 6230687) manages ignition and detection; if the board fails, after opening the gas it does not validate ionisation and, after ~10 s, the boiler goes into lockout, lighting the red LED. Verify correct phase/neutral and spark/detection (electrode and transformer), and if the lockout with red LED persists after the ignition attempt, replace the board.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Sime PCB 6230687

Catalogue reference
6230687
Uniclima internal SKU
PLSI087
Brand
Sime
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Brahma code
16020798
Brahma model
351.7F002
Voltage
230V
Frequency
50-60Hz
Manufacturing date
09-12
PCB code (silkscreen)
BI093I61 R.03
Sime spare part code (label)
Ric. 01-40
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 6230687

Is this Brahma PCB suitable for the Sime Format 25/60 BF?
Yes, it is on the list of compatible models.
What code should my PCB have to be the same as the one for the Sime Metro 25 BF?
The Brahma code 16020798 and model 351.7F002, printed on the label.
Is this Brahma PCB an original Sime part?
The component identified by the label is manufactured by Brahma, not by Sime.
What voltage does the Brahma PCB Cod. 16020798 operate at?
At 230V and 50-60Hz, according to the label.
How many models are compatible with this PCB?
The PCB is compatible with a total of 5 models.
What documented fault code does this PCB present?
Red LED lock on/security thermostat intervention.

Spare parts related to Sime Sime Format

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Brahma PCB Sime Format 25/60 BF Code 16020798