Brahma PCB Sime Format 25/60 BF Code 16020798
Electronic component manufactured by Brahma, identified by code 16020798 and model 351.7F002, with a manufacturing date of 09-12. It operates at 230V and 50-60Hz. It is installed in Sime boilers of the Format, Format ZIP, Metro, and Planet Dewy series. It is replaced when the original module with these same codes fails or stops working.
VAT included
Consult via WhatsAppSime boilers compatible with reference 6230687
PCB with reference 6230687. Five confirmed compatibilities: Format 25/60 BF and Format 30/60 BF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Sime Format 25/60 BF | Sime Format | Contrasted |
| Sime Format 30/60 BF | Sime Format | Contrasted |
| Sime Format 25/60 OF | Sime Format | Contrasted |
| Sime Format ZIP 25 BF | Sime Format | Contrasted |
| Sime Metro 25 BF | Sime Metro | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 6230687 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 6230687. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 6230687 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not start at all, with no sign of activity.
Cause: The Brahma PCB powers and coordinates the rest of the components; if its input stage fails, none of the equipment responds.
Check with a tester that the PCB is receiving the 230V indicated on its label before replacing it; without input voltage, any PCB will remain silent.
- 02
A fault code appears and the boiler does not continue the ignition cycle.
Cause: The PCB aborts the sequence when any safety signal is not as expected, whether the fault is its own or from a connected sensor.
Note the code and compare it with the equipment manual before purchasing; some codes are resolved by checking a sensor, not the PCB.
- 03
The control or the room thermostat is not able to start the boiler.
Cause: The PCB input that receives the heating demand may become inoperative even if the rest of the system is functioning.
Check the thermostat wiring on the PCB terminal block and ensure it is properly bridged before discarding it.
- 04
The pump or the gas valve remain without command even though the boiler is requesting heat.
Cause: The corresponding output relay on the PCB can fail in isolation, without affecting the rest of the functions.
Measure with a tester if there is voltage going to the pump or valve connector when it should; if not, it points to the PCB.
- 05
The boiler intermittently shuts off on its own, especially after it has been running for a while.
Cause: A component of the PCB that degrades with heat can cause interruptions that only appear after a period of use.
Check if the shutdown always occurs after the same operating time; this thermal pattern is typical of a fault in the PCB.
Fault codes for Sime that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| Red LED lockout ignition/safety thermostat intervention | Lockout due to ignition fault or intervention of the safety thermostat. | In these models, the PCB (board 6230687) manages ignition and detection; if the board fails, after opening the gas it does not validate ionisation and, after ~10 s, the boiler goes into lockout, lighting the red LED. Verify correct phase/neutral and spark/detection (electrode and transformer), and if the lockout with red LED persists after the ignition attempt, replace the board. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Sime PCB 6230687
- Catalogue reference
- 6230687
- Brand
- Sime
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Brahma code
- 16020798
- Brahma model
- 351.7F002
- Voltage
- 230V
- Frequency
- 50-60Hz
- Manufacturing date
- 09-12
- PCB code (silkscreen)
- BI093I61 R.03
- Sime spare part code (label)
- Ric. 01-40
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Sime Format 25/60 BF manual (PDF)Document © Sime, provided as a technical reference.