Siemens PCB Baxi Roca Platinum Max Plus 33/33 F Ref. 7113920.02
Control PCB manufactured by Siemens (code 7113920.02, controller LMS15.000A349, firmware V3.8.0.2.1) for Baxi Roca Platinum Max Plus 33/33F boilers. Operates at 230V~/50Hz, made in Germany and CE-0085BU0296 certified. It is replaced when the boiler does not ignite, does not respond to controls, or the display shows a PCB fault.
VAT included
Consult via WhatsAppCompatible Baxi Roca boilers
PCB. A proven compatibility: MAX PLUS 33/33 F.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca MAX PLUS 33/33 F | PLATINUM | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB (control board) resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and does not respond to any controls.
Cause: The PCB controls the entire boiler; if it fails, you cannot operate anything from the panel.
Check if the fuse on the PCB (when visible) is blown before declaring it defective.
- 02
The display shows a fault code directly associated with the control board.
Cause: The firmware of the PCB performs a self-diagnosis and displays an error if it detects an internal anomaly.
Note the exact code displayed: if it is a sensor code (NTC, pressure), the problem may not be the PCB.
- 03
It locks out after a couple of ignition attempts, even though there is gas and a visible flame.
Cause: The safety control of the PCB cuts off if it does not receive the flame signal or the interlocks correctly.
Check the ionization electrode and its connection before replacing the PCB: a faulty flame signal causes the same lockout.
- 04
The room thermostat or the connected accessories stop communicating with the boiler.
Cause: The PCB manages the communication bus with thermostats and external accessories.
Disconnect and reconnect the bus or the thermostat and check if communication is restored before replacing the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca PCB.
- Brand
- Baxi Roca
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Voltage
- 230V~
- Frequency
- 50Hz
- Controller model
- LMS15.000A349
- Firmware version
- V3.8.0.2.1
- Maximum TSA
- 10s
- CE certification
- CE-0085BU0296
- Country of manufacture
- Made in Germany
- Part code (Siemens)
- 7113920.02
- Manufacturer of the relays
- SCHRACK V23061-B1007-A301 (relays, not the complete PCB)
- The visible relays on this PCB are marked SCHRACK: they are the manufacturer of the relays, not the entire PCB (the PCB is Siemens).