
Tifell 25 MT Control PCB Ref. P004N2
Control PCB for Tifell 25 and 25 MT. There is no visible manufacturer logo on the physical board; the code P004N2 and the marking CE-0051BP2733 can be read. The reference CM76666LA currently used in the catalog does not appear printed on the part.
VAT included
Consult via WhatsAppTifell boilers compatible with reference CM76666LA
PCB with reference CM76666LA. A proven compatibility: Tifell 25 MT.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Tifell Tifell 25 MT | Tifell 25 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference CM76666LA is the part for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference CM76666LA. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the CM76666LA PCB solves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not turn on, there are no lights or display.
Cause: The PCB controls the internal power supply of the unit; if it fails, the other components do not receive power.
Check the main fuse of the boiler and the circuit breaker of the installation before replacing the PCB.
- 02
An error code appears that does not reset even when the boiler is turned off and on.
Cause: The PCB blocks operation when a safety signal is incorrect, either due to a fault in the PCB or in a connected sensor.
Note the exact code and consult the manual before purchasing; some codes indicate a problem in a component different from the PCB.
- 03
The remote control or the thermostat cannot start the boiler.
Cause: The input of the PCB that receives the heating command can fail without affecting the other functions.
Check the wiring of the thermostat at its terminal block and the batteries of the remote control before considering it faulty.
- 04
The boiler turns off by itself intermittently during operation.
Cause: A component of the PCB that wears out with use or heat can cause shutdowns without a fixed pattern.
Note when the shutdown occurs (during startup, with hot water, in heating) to identify the cause before replacing the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Tifell CM76666LA PCB.
- Catalogue reference
- CM76666LA
- Brand
- Tifell
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- CE marking
- CE-0051BP2733
- PCB code
- P004N2
- Batch or manufacturing date
- 2305
