Cointra Optimax OM 21 EI Air Pressure Switch Ref. 9160130

Cointra Optimax OM 21 EI Air Pressure Switch Ref. 9160130

Stock · 5 units

Cointra Optimax presents the Optimax OM 21 EI air pressure switch, which is responsible for monitoring the air pressure and authorizing the operation of the boiler. When this part fails, the boiler does not start or gets locked, even if the actual pressure is correct. This pressure switch is compatible with the Cointra Optimax OM 21 EI boiler, among others. It should be replaced when you notice that the boiler does not start correctly or experiences lockouts due to pressure issues.

VAT included

Compatibility

Cointra boilers compatible with reference 9160130

Pressure switch with reference 9160130. A proven compatibility: Optimax OM 21 EI.

Proven compatibility

Boiler modelFamilyVerification
Cointra Optimax OM 21 EICointra OptimaxContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 9160130 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 9160130. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 9160130 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and shows an air pressure fault when trying to start.

    Cause: The pressure switch does not detect the minimum pressure of the fan and does not allow ignition.

    Check that the fan rotates freely and reaches the appropriate speed before ignition, without any noise or blockages.

  • 02

    The fan starts, but the burner never ignites.

    Cause: The internal contact of the pressure switch does not activate even though the air pressure is correct, due to wear or dirt.

    Measure with a multimeter if the pressure switch closes the contact when the fan is functioning correctly.

  • 03

    The boiler starts intermittently: sometimes it ignites and other times it turns off by itself.

    Cause: An irregular switching of the pressure switch causes the control unit to receive unstable pressure signals.

    Check that the silicone tubes connecting the pressure switch to the fan are not loose, cracked, or blocked.

  • 04

    The blockage occurs right at startup, before the flame appears.

    Cause: The pressure switch stops the ignition in the first second if it does not detect sufficient air pressure, for safety reasons.

    Check that the flue outlet and the external air intake are not obstructed by dirt, nests, or ice.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for Cointra pressure switch 9160130

Catalogue reference
9160130
Brand
Cointra
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component code
PRS0003P1
Secondary code
605.99419
Switching pressure
120/100 Pa
Electrical classification
1 (0.5) A / 250V~
Batch code
RN206A
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch 9160130

Is this pressure switch suitable for any Cointra Optimax boiler or only for the OM 21 EI?
It is only listed as compatible with the Cointra Optimax OM 21 EI; there are no other Optimax models registered in the datasheet.
What code is printed on the pressure switch Ref. 9160130?
PRS0003P1, with the secondary code 605.99419.
What fault does it resolve when replacing it in the OM 21 EI?
Fix the air pressure switch fault that locks the boiler or prevents the burner from igniting.
At what pressure does the pressure switch of the Cointra Optimax OM 21 EI switch?
At 120/100 Pa, according to the label.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Cointra Optimax OM 21 EI Air Pressure Switch Ref. 9160130