Honeywell Smoke Pressure Switch Biasi GME24 C6065FH1227:2 Ref. BI1036102

Honeywell Smoke Pressure Switch Biasi GME24 C6065FH1227:2 Ref. BI1036102

Stock · 5 units

Differential pressure switch for flue gases for Biasi GME24 boilers and related models. Manufactured by Honeywell (Yamatake-Honeywell), model C6065FH1227:2, set at 1.33 mbar with a maximum of 6 mbar. It checks the flue gas pressure before allowing the burner to ignite; if it detects a value out of range, it locks the boiler. It is replaced when the boiler does not ignite or stops due to a draft fault.

VAT included

Compatibility

Biasi boilers compatible with reference BI1036102

Pressure switch with reference BI1036102. A verified compatibility: Micon 24 E.

Proven compatibility

Boiler modelFamilyVerification
Biasi Micon 24 EMiconContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. BI1036102 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference BI1036102. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch BI1036102 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler goes through the ignition cycle, the fan spins, but it stops and locks out before the flame ignites.

    Cause: The flue pressure switch does not detect sufficient depression in the exhaust, and the control unit does not allow gas flow.

    Check that the flue gas outlet duct is not obstructed, crushed, or has too much horizontal run before replacing the pressure switch.

  • 02

    The display shows a flue or exhaust fault code.

    Cause: It is the reading given by the control unit when the pressure switch does not close the contact within the safety time.

    Check the silicone tubes connecting the pressure switch to the duct: make sure they are not bent, punctured, or disconnected.

  • 03

    The boiler shuts off on its own while in operation, not just when turning on.

    Cause: A pressure variation in the exhaust during combustion causes the pressure switch to open the contact and shut off the burner for safety.

    Check that the flue outlet to the outside is not facing against the wind, has no bird nests, or is not obstructed.

  • 04

    The fan sounds and spins normally, but the boiler still locks out.

    Cause: If the fan is working properly, the draft fault usually comes from the pressure switch or its pressure connections, not the motor.

    With the boiler off, use a multimeter to check that the pressure switch closes the contact when gently blowing through the tube, before considering it faulty.

Fault codes for Biasi that this part resolves.

CodeFaultDiagnosis and solution
E05Flue pressure switch anomalyA problem has been detected in the flue gas evacuation. This can be dangerous and requires immediate attention. If the boiler shows this code, it is possible that the flue pressure switch is faulty or there is a blockage in the evacuation system.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for the Biasi BI1036102 pressure switch

Catalogue reference
BI1036102
Brand
Biasi
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component code
C6065FH1227:2
Electrical marking (silkscreen)
1.5(0.5)μ 250V~
Set pressure
P= 1.33 mbar
Maximum pressure
6 mbar
CE marking
CE-0063AP3085/1
Batch code/date
0008D
Contact settings
NC — C — NO (microswitch)
Manufacturer (embedded in casing)
Yamatake-Honeywell — Made in Japan
Additional marking on the rear label
GME 24 ES N249150301
Frequently Asked Questions

Frequently asked questions about the pressure switch BI1036102

Is this pressure switch suitable for the Biasi GME24?
Yes, it is the original pressure switch for that boiler.
Who manufactures the pressure switch for the Biasi GME24, Honeywell or Biasi?
Manufactured by Honeywell (Yamatake-Honeywell), model C6065FH1227:2; BI1036102 is the reference code used by Biasi for the same part.
What fault does this pressure switch resolve in the GME24?
Correct the lockout due to draft failure: check the flue gas pressure before ignition, and if it detects a value out of range, it locks the boiler.
What pressure is the pressure switch of the Biasi GME24 set to?
At 1.33 mbar, with a maximum of 6 mbar.
How can I identify if my boiler is compatible with the pressure switch PREMNGME24?
Check that your boiler is the Micon 24 E model, as it is the only confirmed compatible model.

Spare parts related to Biasi Micon

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell Smoke Pressure Switch Biasi GME24 C6065FH1227:2 Ref. BI1036102