Water Pressure Switch Biasi Mura 24 E - Honeywell C6065AH1103:2

Water Pressure Switch Biasi Mura 24 E - Honeywell C6065AH1103:2

Stock · 5 units

Honeywell water pressure switch model C6065AH1103:2, installed in Biasi Mura 24E boilers and other Biasi models. It cuts off ignition if it does not detect the minimum water pressure in the circuit. Set at 0.49 mbar, maximum allowable 6 mbar. The body also features "Yamatake Corporation" alongside the Honeywell brand. It is replaced if the boiler locks out due to low water pressure.

VAT included

Compatibility

Compatible Biasi boilers

Pressure switch. Ten confirmed compatibilities: Activ A 25C and Activ A 30C.

Proven compatibility

Boiler modelFamilyVerification
Biasi Activ A 25CBiasiContrasted
Biasi Activ A 30CBiasiContrasted
Biasi Activ A 35CBiasiContrasted
Biasi Basica M97R.24CMBiasiContrasted
Biasi RinNova Cond Plus M260V.2025SMBiasiContrasted
Biasi RinNova Cond Plus M260V.3035SMBiasiContrasted
Biasi MURA 24EBiasiContrasted
Biasi MURA v09 24EBiasiContrasted
Biasi MYTO CONDENS PLUS 24BiasiContrasted
Biasi MYTO CONDENS PLUS 35BiasiContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch resolves

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and shows a warning of low water pressure, even though the circuit is full.

    Cause: The water pressure switch does not detect the minimum required pressure and blocks the ignition for safety, even though the manometer is correct.

    Check the pressure on the boiler's manometer before replacing the pressure switch: if it is really low, the problem is with the water, not the part.

  • 02

    The low pressure warning disappears after bleeding the circuit or refilling with the filling key.

    Cause: Air trapped in the circuit can simulate a lack of pressure that the pressure switch interprets as real.

    Bleed the radiators and the boiler properly before considering that the pressure switch is faulty.

  • 03

    The boiler intermittently locks out due to water pressure, especially when cold.

    Cause: Small pressure variations with the cold installation can cause a worn pressure switch to malfunction.

    Record the cold and hot pressure over several days to check for a real pressure loss in the system.

  • 04

    The expansion vessel has been checked and the installation is not leaking water, but the warning still appears.

    Cause: If a leak or a depleted expansion vessel has been ruled out, the erroneous signal usually comes from the pressure switch itself.

    With the installation checked and without leaks, measure the continuity of the pressure switch before replacing it.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Biasi pressure switch datasheet

Brand
Biasi
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Model
C6065AH1103:2
Brand on label
Honeywell
Manufacturer on the body
Yamatake Corporation
Contact electric charge
1.5(0.5) A / 250 V~
Set pressure
0.49 mbar
Maximum allowable pressure
6 mbar
Date code
0905M
CE code / notified body
CE-0063AP3085/1
Frequently Asked Questions

Frequently asked questions about the pressure switch

Is this Honeywell C6065AH1103:2 pressure switch suitable for the Biasi Mura 24E?
Yes, it is the factory-mounted water pressure switch in the Biasi Mura 24E, as well as other Biasi models from the compatibility list.
Who manufactures the pressure switch for the Biasi Mura 24E, Honeywell or Yamatake?
Both names appear on the body of the piece: Honeywell as the brand and Yamatake Corporation printed next to it.
At what pressure does the pressure switch C6065AH1103:2 cut off?
It is set to 0.49 mbar, with a maximum allowable of 6 mbar.
When should this pressure switch be replaced in a Biasi Activ A 25C?
When the boiler locks out due to a lack of minimum water pressure in the circuit, as it is that signal that cuts off the ignition.
Is the same pressure switch used for the Biasi Myto Condens Plus 24 and 35?
Yes, both models are on the list of boilers compatible with this reference.

Spare parts related to Biasi

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts