Water Pressure Switch Biasi Mura 24 E - Honeywell C6065AH1103:2
Honeywell water pressure switch model C6065AH1103:2, installed in Biasi Mura 24E boilers and other Biasi models. It cuts off ignition if it does not detect the minimum water pressure in the circuit. Set at 0.49 mbar, maximum allowable 6 mbar. The body also features "Yamatake Corporation" alongside the Honeywell brand. It is replaced if the boiler locks out due to low water pressure.
VAT included
Consult via WhatsAppCompatible Biasi boilers
Pressure switch. Ten confirmed compatibilities: Activ A 25C and Activ A 30C.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Activ A 25C | Biasi | Contrasted |
| Biasi Activ A 30C | Biasi | Contrasted |
| Biasi Activ A 35C | Biasi | Contrasted |
| Biasi Basica M97R.24CM | Biasi | Contrasted |
| Biasi RinNova Cond Plus M260V.2025SM | Biasi | Contrasted |
| Biasi RinNova Cond Plus M260V.3035SM | Biasi | Contrasted |
| Biasi MURA 24E | Biasi | Contrasted |
| Biasi MURA v09 24E | Biasi | Contrasted |
| Biasi MYTO CONDENS PLUS 24 | Biasi | Contrasted |
| Biasi MYTO CONDENS PLUS 35 | Biasi | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch resolves
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and shows a warning of low water pressure, even though the circuit is full.
Cause: The water pressure switch does not detect the minimum required pressure and blocks the ignition for safety, even though the manometer is correct.
Check the pressure on the boiler's manometer before replacing the pressure switch: if it is really low, the problem is with the water, not the part.
- 02
The low pressure warning disappears after bleeding the circuit or refilling with the filling key.
Cause: Air trapped in the circuit can simulate a lack of pressure that the pressure switch interprets as real.
Bleed the radiators and the boiler properly before considering that the pressure switch is faulty.
- 03
The boiler intermittently locks out due to water pressure, especially when cold.
Cause: Small pressure variations with the cold installation can cause a worn pressure switch to malfunction.
Record the cold and hot pressure over several days to check for a real pressure loss in the system.
- 04
The expansion vessel has been checked and the installation is not leaking water, but the warning still appears.
Cause: If a leak or a depleted expansion vessel has been ruled out, the erroneous signal usually comes from the pressure switch itself.
With the installation checked and without leaks, measure the continuity of the pressure switch before replacing it.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Biasi pressure switch datasheet
- Brand
- Biasi
- Type of part
- Pressure switches
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Model
- C6065AH1103:2
- Brand on label
- Honeywell
- Manufacturer on the body
- Yamatake Corporation
- Contact electric charge
- 1.5(0.5) A / 250 V~
- Set pressure
- 0.49 mbar
- Maximum allowable pressure
- 6 mbar
- Date code
- 0905M
- CE code / notified body
- CE-0063AP3085/1