Wilo NFSL12/5-HE-1 C Circulating Pump for Biasi Minox Eco 24 E Boiler - Ref. 4022 3080 28/0
Wilo circulator pump, model NFSL12/5-HE-1 C, installed in Biasi boilers (Minox Eco 24 E, Mura 24 E, Mura 24 A, and Delta/M97). It moves the water in the heating circuit. It is replaced when the motor does not start, makes noise, or loses flow. Insulation class H, IP44, nominal pressure PN6, and up to 95°C. The label literally states ~230V-60Hz.
VAT included
Consult via WhatsAppBiasi boilers compatible with reference BI1352100
Circulating pump with reference BI1352100. Four confirmed compatibilities: Minox Eco 24 E and Minox Eco 28 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Minox Eco 24 E | Minox Eco | Contrasted |
| Biasi Minox Eco 28 E | Minox Eco | Contrasted |
| Biasi Mura 24 A | Mura | Contrasted |
| Biasi Delta M97.23SM | Delta | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. BI1352100 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI1352100. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulation pump BI1352100 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler ignites but the heating does not heat or heats little.
Cause: The pump is not circulating the hot water properly.
Check if there is a temperature difference between the supply pipe and the return pipe in a radiator close to the boiler.
- 02
There is noise or vibration in the pump when the heating is turned on.
Cause: The noise may be caused by air in the circuit or a worn bearing.
Bleed the circuit before assuming that the noise is coming from the pump.
- 03
The pump motor does not start when the heating requests heat.
Cause: There may be no power supply, or the winding or rotor may be damaged or stuck.
Check that power is reaching the pump connector and that the shaft turns freely by moving it by hand with the boiler turned off.
- 04
Water is dripping from the pump shaft.
Cause: The mechanical seal that seals the shaft has worn out and is no longer watertight.
Dry the area and check after a while of operation if the leak comes from the body of the pump or from a nearby gasket.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Biasi BI1352100 circulator pump.
- Catalogue reference
- BI1352100
- Brand
- Biasi
- Type of part
- Pumps
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Insulation class
- Class H
- Nominal Pressure (PN)
- PN6
- Fluid Temperature (TF)
- TF95
- Degree of protection
- IP44
- Condenser
- 2µF
- Voltage/Frequency
- ~230V-60Hz
- Current/Power
- 0.34 A / 77 W
- Reference (Ref)
- 4022 3080 28/0
- Type
- NFSL12/5-HE-1 C
- Serial number (No.)
- 4516443
- Manufacturing code
- 4518536
- Week/year of manufacture
- 08W45