Honeywell Pressure Switch C6065A1226 For Neckar Bosch Novastar New 24 AE Boiler

Honeywell Pressure Switch C6065A1226 For Neckar Bosch Novastar New 24 AE Boiler

Pressure switch model C6065A1226, manufactured by Honeywell (engraved on the body as Yamatake-Honeywell) and made in Japan. It has a setting of 0.65 mbar (maximum 6 mbar) and contacts of 1.5(0.5)A at 250V~, complying with the DIN-DVGW 88.06 b 050 standard. It cuts the circuit if the pressure goes out of that range. The batch read on the label is 9404DYM. Compatible with the Neckar Bosch Novastar New 24 AE boiler.

Type of part
Pressure switches
Catalogue reference
87161461360
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Neckar boilers compatible with reference 87161461360

Pressure switch with reference 87161461360. A verified compatibility: Bosch Novastar New 24 AE.

Proven compatibility

Boiler modelFamilyVerification
Neckar Bosch Novastar New 24 AENeckarContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87161461360 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87161461360. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the pressure switch 87161461360

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler tries to ignite and quickly shuts off, without heating.

    Cause: The pressure switch does not close the contact properly and the control board cuts off the gas supply.

    Check that the extractor is working properly and without obstructions before inspecting the pressure switch.

  • 02

    It is necessary to turn the boiler off and on several times for it to start.

    Cause: An unstable closing pressure switch causes intermittent lockouts that are temporarily resolved by resetting.

    With the boiler on, use a multimeter to check if the pressure switch contact remains closed steadily.

  • 03

    The boiler takes longer than usual in the pre-ignition phase, as if it hesitates.

    Cause: The pressure switch takes time to close because the air pressure signal is weak or irregular.

    Check that the air intake and flue gas outlet ducts are clean and free of obstructions.

  • 04

    The fault occurs especially on very windy days or with a long flue.

    Cause: External conditions affect the pressure that the pressure switch receives, which may be right at the limit of its adjustment.

    Note if the problem occurs on windy days before considering that the pressure switch is faulty.

Neckar fault codes that require diagnosis

CodeFaultTechnical checks
C1The pressure switch has activated during operation.The air pressure switch detects a loss of depression/draft (obstruction in venturi/hoses or fatigued diaphragm) and opens the circuit; check continuity in COM/NO while the fan starts and inspect connections, tubes, and venturi.
C4The pressure switch does not open in the rest position.The pressure switch contact remains closed at rest due to a stuck diaphragm or blocked tube; check with a multimeter that the micro switch opens without depression and clean/renew hoses and connection to the venturi.
C6The pressure switch (differential) does not close.With the fan running, the minimum depression is not reached due to lack of draft/obstruction or a misadjusted/faulty pressure switch; measure the electrical closure of the micro when applying depression and check the flue, venturi, and tubes.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for the Neckar pressure switch 87161461360

Catalogue reference
87161461360
Uniclima internal SKU
PCNN24AE
Brand
Neckar
Type of part
Pressure switches
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Model
C6065A1226
Manufacturer (engraved on the body)
Yamatake-Honeywell
Voltage
250V~
Contacts
1.5(0.5)µ/250V~
Set pressure
P=0.65 mbar, max. 6 mbar
Regulations
DIN-DVGW 88.06 b 050
Batch code
9404DYM
Place of manufacture
MADE IN JAPAN
Frequently Asked Questions

Frequently asked questions about the pressure switch 87161461360

Which manufacturer makes the pressure switch for the Neckar Bosch Novastar New 24 AE?
Honeywell; on the body it is engraved as 'Yamatake-Honeywell'.
Where is this pressure switch C6065A1226 manufactured?
In Japan, according to the 'MADE IN JAPAN' mark on the back casing.
What is the set pressure of the pressure switch for the Novastar New 24 AE?
0.65 mbar, with a maximum allowable of 6 mbar.
What electrical contacts does this pressure switch have on the Novastar New 24 AE?
1.5(0.5) A at 250 V~, complying with standard DIN-DVGW 88.06 b 050.
Is this Honeywell C6065A1226 pressure switch only suitable for the Neckar Bosch Novastar New 24 AE?
According to the available material, that is the only boiler indicated as compatible with this part.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Honeywell Pressure Switch C6065A1226 For Neckar Bosch Novastar New 24 AE Boiler