Honeywell Air Pressure Switch C4065FH1024:2 For Microtec / T2 / Uno MFFI

Honeywell Air Pressure Switch C4065FH1024:2 For Microtec / T2 / Uno MFFI

Stock · 5 units

Air pressure switch manufactured by Honeywell (the Yamatake brand also appears on the label), which checks the flue extraction pressure before ignition. Set to 0.55 mbar, maximum 6 mbar, and powered at 125 V. It is replaced when the boiler does not ignite, locks out, or displays a pressure switch or flue extraction error.

VAT included

Compatibility

Compatible Ariston boilers

Pressure switch. Five confirmed compatibilities: 23 MFFI and Plus 24 MFFI.

Proven compatibility

Boiler modelFamilyVerification
Ariston 23 MFFIMicrogenusContrasted
Ariston Plus 24 MFFIMicrogenusContrasted
Ariston 23 MFFIMicrotecContrasted
Ariston 23 MFFIT2Contrasted
Ariston 24 MFFIOneContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch resolves

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and locks out when trying to start.

    Cause: The pressure switch does not close the low pressure contact that allows the burner to ignite.

    Make sure that the extractor starts without any strange noises and reaches its maximum speed before considering the pressure switch.

  • 02

    The display shows a fault code related to the pressure switch or the flue gas extraction.

    Cause: The control unit detects that the pressure signal is not reaching or is out of range and stops the cycle for safety.

    Clear the fault and repeat the ignition, observing if the fault always appears at the same moment in the cycle.

  • 03

    The extractor can be heard running, but the boiler remains idle, as if waiting for something.

    Cause: The extractor works, but the pressure switch does not send the correct pressure signal to the control board to continue.

    Check that the silicone tubes of the pressure switch are not punctured, sagging, or filled with water.

  • 04

    The fault comes and goes: sometimes it ignites on the first try and other times it gets blocked.

    Cause: A pressure switch with a worn contact may close intermittently depending on vibration or the exact pressure point.

    Before changing it, clean the air intake filter and make sure there are no leaks in the pressure tube connections.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Ariston pressure switch datasheet

Brand
Ariston
Type of part
Pressure switches
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Honeywell
Component code
C4065FH1024:2
Condenser
0.1 µF
Voltage
125V~
Set pressure
P=0.55 mbar
Maximum pressure
max. 6 mbar
Date code
0148F
CE Certificate
CE-0063AP3085/1
Place of manufacture
MADE IN CHINA
Secondary brand on label
Yamatake
Before purchasing
  • The current catalog reference is empty; there is no catalog number to compare with.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch

Does this Honeywell C4065FH1024:2 pressure switch work for a Microgenus Plus 24 MFFI?
Yes, it is on the list of compatible boilers, along with Microgenus 23 MFFI, Microtec 23 MFFI, T2 23 MFFI, and Uno 24 MFFI.
Who manufactures this pressure switch for the Microtec 23 MFFI?
Honeywell; the label also shows the Yamatake brand.
What is the set pressure of the pressure switch for the T2 23 MFFI?
0.55 mbar, with a maximum of 6 mbar, according to the label.
What voltage does this pressure switch of the Uno 24 MFFI support?
125 V, according to the label.
What fault indicates that this pressure switch needs to be replaced in a Microgenus 23 MFFI?
The boiler does not ignite, it locks out or shows a fault related to the pressure switch or flue gas extraction, as this component checks the extraction pressure before ignition.
What is the exact code engraved on the Microtec / T2 / Uno MFFI part?
C4065FH1024:2, printed on the label.

Spare parts related to Ariston Microgenus

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Honeywell Air Pressure Switch C4065FH1024:2 For Microtec / T2 / Uno MFFI