Ariston Air Pressure Switch (models MFFI/BFFI) - Ref. 605 99509

Ariston Air Pressure Switch (models MFFI/BFFI) - Ref. 605 99509

Stock · 1 unit

In the Ariston boilers from the MFFI/BFFI ranges, the Air Pressure Switch (Ref. 605 99509) is responsible for checking the air pressure and authorizing the operation of the boiler. If this part fails, you will notice that the boiler does not start or gets locked, even if the pressure is correct, and it may display fault codes such as E33 or E34. It is compatible with models like 24 MFFI, 23 MFFI, and 27 BFFI, among others. It should be replaced when it shows faults in pressure or prevents the boiler from igniting.

VAT included

Compatibility

Ariston boilers compatible with reference 998484-01

Pressure switch with reference 998484-01. Eight confirmed compatibilities: 24 MFFI and 23 MFFI.

Proven compatibility

Boiler modelFamilyVerification
Ariston 24 MFFICityContrasted
Ariston 23 MFFIESTContrasted
Ariston 27 BFFIGenusContrasted
Ariston 23 MFFIMicrocombiContrasted
Ariston 23 MFFIMicrogenusContrasted
Ariston 23 MFFIMicrotecContrasted
Ariston 23 MFFIT2Contrasted
Ariston 24 MFFIONEContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 998484-01 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 998484-01. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 998484-01 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The extractor works and sounds fine, but the boiler does not ignite the burner.

    Cause: The pressure switch does not indicate to the control board that there is sufficient pressure in the air circuit, so the gas does not open.

    Check that the connection tube from the pressure switch to the fan is not disconnected, crushed, or has condensation inside.

  • 02

    The display shows an air pressure switch warning that sometimes disappears after resetting.

    Cause: An intermittent fault is usually caused by a contact that degrades before fully opening.

    Reset and note if the fault takes longer or shorter to reoccur; if it is more frequent, the part is failing.

  • 03

    The boiler fails more when starting cold in the morning than during the rest of the day.

    Cause: The pressure switch is sensitive to small variations, and dirt or cold can cause it to fail only during startup.

    Carefully clean the area around the pressure inlet and check for any dust or soot buildup before replacing the part.

  • 04

    The extractor is spinning but it seems to be struggling, and just then the pressure switch fault occurs.

    Cause: If the extractor loses power, the pressure switch stops receiving the minimum pressure even if it is in good condition.

    Check the condition of the extractor (noise, vibration, speed) before assuming that the pressure switch is the culprit.

Fault codes for Ariston that this part resolves.

CodeFaultDiagnosis and solution
E33The air pressure switch is closed before the ignition sequence.The pressure switch remains closed at rest (membrane stuck or wiring/connections reversed). Check with a multimeter that it is open at rest and inspect/clean the connections and pressure tubes.
E34The air pressure switch does not close when the fan operates.The pressure switch does not change state when the fan starts (contacts open due to internal fault or insufficient ΔP). Check continuity during start-up and measure depression with a differential manometer; inspect pressure tubes/connections.
607Authorization of the flue pressure switch preceding the ignition sequence.The pressure switch appears 'ON' when it shouldn't (contacts stuck or connections improperly made). Verify that it is open at rest and that the connections do not create undue depression.
608No authorization from the flue gas pressure switch with the fan on.The pressure switch does not close despite the fan turning (defective diaphragm/switch or insufficient ΔP). Check continuity when starting and measure ΔP; inspect tubes and chimney obstructions.
6P1Delay in air pressure switch authorization.The pressure switch takes time to close due to being sluggish or due to limit depression. Check the closing time with a multimeter and measure ΔP during pre-ventilation; clean/adjust connections.
6P2Air pressure switch opening during operation.The pressure switch opens during operation (unstable contact or draft/pressure drop). Check continuity in operation and measure sustained ΔP; inspect tubes, obstructions, and the pressure switch itself.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for Ariston Pressure Switch 998484-01

Catalogue reference
998484-01
Brand
Ariston
Type of part
Pressure switches
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Label code
605 99509
Switching pressure
40/△+12 Pa
Range
0.2(0.1)/30~
Batch code
CHKDCC
Serial number/batch
MTS 2399551018000
Frequently Asked Questions

Frequently asked questions about the pressure switch 998484-01

Does the pressure switch Ref. 605 99509 work for an Ariston Genus 27 BFFI?
Yes, the Genus 27 BFFI is among the Ariston boilers compatible with this part, along with City 24 MFFI, EST 23 MFFI, Microcombi 23 MFFI, Microgenus 23 MFFI, Microtec 23 MFFI, T2 23 MFFI, and UNO 24 MFFI.
What fault does this pressure switch resolve in an Ariston MFFI boiler?
It is replaced when the boiler does not start or shows a pressure switch fault, as it controls the pressure of the extractor before ignition.
At what pressure does the pressure switch of the Ariston UNO 24 MFFI switch?
According to the label, it switches to 40/△+12 Pa, with a range of 0.2(0.1)/30~.

Spare parts related to Ariston City

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Ariston Air Pressure Switch (models MFFI/BFFI) - Ref. 605 99509