
Circulating Pump for Saunier Duval Renova Ref. 0020023217
When you start the heating in your home, the Saunier Duval Renova circulating pump is the component responsible for moving water through the heating circuit. If it fails, you will notice cold radiators, strange noises, or even overheating, which can lead to blockages due to lack of circulation. This pump is compatible with several models from the Renova range, such as the C24, F24, and Mini H13, among others. It should be replaced when you experience symptoms of malfunction or faults such as F.75, F.23, F.24, or F.20.
VAT included
Consult via WhatsAppRenova boilers compatible with reference 0020023217
Circulating pump with reference 0020023217. 18 verified compatibilities: 23 kW (Glow-worm / Jaguar) and LEOPARD 24 BOV.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Renova 23 kW (Glow-worm / Jaguar) | Jaguar | Contrasted |
| Renova LEOPARD 24 BOV | Protherm | Contrasted |
| Renova LEOPARD 24 BTV | Protherm | Contrasted |
| Renova LEV 20 KKZ | Protherm | Contrasted |
| Renova LEV 30 KKZ | Protherm | Contrasted |
| Renova PANTHER 12 KOO | Protherm | Contrasted |
| Renova PANTHER 12 KTO | Protherm | Contrasted |
| Renova PANTHER 24 KOO | Protherm | Contrasted |
| Renova PANTHER 24 KOV | Protherm | Contrasted |
| Renova PANTHER 24 KOVLN | Protherm | Contrasted |
| Renova PANTHER 24 KTO | Protherm | Contrasted |
| Renova PANTHER 24 KTV | Protherm | Contrasted |
| Renova REJNOK 6-28 K11/K12 | Protherm | Contrasted |
| Renova Duval Renova C24 | Saunier | Contrasted |
| Renova Duval Renova F24 | Saunier | Contrasted |
| Renova Duval Renova Mini H13 | Saunier | Contrasted |
| Renova Duval Renova Mini H15 | Saunier | Contrasted |
| Renova Duval Renova Mini H17 | Saunier | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 0020023217 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 0020023217. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulation pump 0020023217 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is not heating properly because the water is not circulating.
Cause: the pump does not move the water between the boiler and the radiators
Measure the temperature between the supply pipe and the return pipe before declaring the pump faulty.
- 02
The pump does not start when the heating is turned on.
Cause: the shaft may be seized due to sediment if it has been out of operation for a long time
With the boiler turned off, try to manually turn the shaft through the front cap before replacing it.
- 03
There is noise or vibration in the pump area.
Cause: Air trapped in the rotor causes cavitation.
Bleed the air through the front screw of the pump and through the highest radiators before replacing it.
- 04
There is a water leak from the pump shaft.
Cause: the mechanical seal has lost its tightness with use
Dry the area and check after a while of operation if the leak reappears right at the shaft.
Fault codes for Renova that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F.75 | Pump error/lack of water: no pressure increase detected when the pump starts. | The circulator 0020023217 is blocked or faulty and does not generate the pressure increase that the sensor should read; check by activating the pump directly (rotation/consumption) and observing the pressure sensor value during the pre-start. |
| F.23 | Safety shutdown: excessive flow/return temperature variation (lack of circulation). | If the 0020023217 does not provide flow (blocked or with reduced power), the flow heats up much faster than the return; check the pump's consumption/rotation and the ΔT in diagnostics. |
| F.24 | Safety shutdown: temperature rise too fast due to lack of circulation. | The fault of the 0020023217 causes a sudden rise in temperature in the primary; check that the pump is rotating and providing flow (bleed/diagnostic mode) and that there is no air in the circuit. |
| F.20 | Safety shutdown: temperature limiter (heat exchanger overheating). | With the 0020023217 blocked or without performance, the water does not circulate and the heat exchanger overheats until the limiter trips; check pump rotation/consumption, bleed, and confirm actual flow rate. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the circulator pump Renova 0020023217
- Catalogue reference
- 0020023217
- Brand
- Renova
- Type of part
- Pumps
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Condenser
- 2.6 µF
- Voltage / frequency
- 400VDB / ~230V - 50Hz
- Pressure / protection rating
- PN6 - IP42
- Thermal class
- Class F - TF95
- Speed
- 2200 min-1
- Current / power
- 0.36 A / 83 W
- Manufacturing date
- 02/22
- Additional code (possible batch, not reference)
- 4508077
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Renova Duval Renova Mini H15 Manual (PDF)Document © Renova, provided as a technical reference.






