Circulating Pump for Saunier Duval Renova Ref. 0020023217
RefurbishedRenovaPumpsWilo

Circulating Pump for Saunier Duval Renova Ref. 0020023217

Stock · 5 units

When you start the heating in your home, the Saunier Duval Renova circulating pump is the component responsible for moving water through the heating circuit. If it fails, you will notice cold radiators, strange noises, or even overheating, which can lead to blockages due to lack of circulation. This pump is compatible with several models from the Renova range, such as the C24, F24, and Mini H13, among others. It should be replaced when you experience symptoms of malfunction or faults such as F.75, F.23, F.24, or F.20.

VAT included

Compatibility

Renova boilers compatible with reference 0020023217

Circulating pump with reference 0020023217. 18 verified compatibilities: 23 kW (Glow-worm / Jaguar) and LEOPARD 24 BOV.

Proven compatibility

Boiler modelFamilyVerification
Renova 23 kW (Glow-worm / Jaguar)JaguarContrasted
Renova LEOPARD 24 BOVProthermContrasted
Renova LEOPARD 24 BTVProthermContrasted
Renova LEV 20 KKZProthermContrasted
Renova LEV 30 KKZProthermContrasted
Renova PANTHER 12 KOOProthermContrasted
Renova PANTHER 12 KTOProthermContrasted
Renova PANTHER 24 KOOProthermContrasted
Renova PANTHER 24 KOVProthermContrasted
Renova PANTHER 24 KOVLNProthermContrasted
Renova PANTHER 24 KTOProthermContrasted
Renova PANTHER 24 KTVProthermContrasted
Renova REJNOK 6-28 K11/K12ProthermContrasted
Renova Duval Renova C24SaunierContrasted
Renova Duval Renova F24SaunierContrasted
Renova Duval Renova Mini H13SaunierContrasted
Renova Duval Renova Mini H15SaunierContrasted
Renova Duval Renova Mini H17SaunierContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 0020023217 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 0020023217. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulation pump 0020023217 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is not heating properly because the water is not circulating.

    Cause: the pump does not move the water between the boiler and the radiators

    Measure the temperature between the supply pipe and the return pipe before declaring the pump faulty.

  • 02

    The pump does not start when the heating is turned on.

    Cause: the shaft may be seized due to sediment if it has been out of operation for a long time

    With the boiler turned off, try to manually turn the shaft through the front cap before replacing it.

  • 03

    There is noise or vibration in the pump area.

    Cause: Air trapped in the rotor causes cavitation.

    Bleed the air through the front screw of the pump and through the highest radiators before replacing it.

  • 04

    There is a water leak from the pump shaft.

    Cause: the mechanical seal has lost its tightness with use

    Dry the area and check after a while of operation if the leak reappears right at the shaft.

Fault codes for Renova that this spare part resolves.

CodeFaultDiagnosis and solution
F.75Pump error/lack of water: no pressure increase detected when the pump starts.The circulator 0020023217 is blocked or faulty and does not generate the pressure increase that the sensor should read; check by activating the pump directly (rotation/consumption) and observing the pressure sensor value during the pre-start.
F.23Safety shutdown: excessive flow/return temperature variation (lack of circulation).If the 0020023217 does not provide flow (blocked or with reduced power), the flow heats up much faster than the return; check the pump's consumption/rotation and the ΔT in diagnostics.
F.24Safety shutdown: temperature rise too fast due to lack of circulation.The fault of the 0020023217 causes a sudden rise in temperature in the primary; check that the pump is rotating and providing flow (bleed/diagnostic mode) and that there is no air in the circuit.
F.20Safety shutdown: temperature limiter (heat exchanger overheating).With the 0020023217 blocked or without performance, the water does not circulate and the heat exchanger overheats until the limiter trips; check pump rotation/consumption, bleed, and confirm actual flow rate.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the circulator pump Renova 0020023217

Catalogue reference
0020023217
Brand
Renova
Type of part
Pumps
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Condenser
2.6 µF
Voltage / frequency
400VDB / ~230V - 50Hz
Pressure / protection rating
PN6 - IP42
Thermal class
Class F - TF95
Speed
2200 min-1
Current / power
0.36 A / 83 W
Manufacturing date
02/22
Additional code (possible batch, not reference)
4508077
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the circulator pump 0020023217

Is this pump suitable for a Protherm Panther 24 KTV?
Yes, it is on the list of compatible boilers, along with the rest of the Panther, Leopard, Rejnok, and Lev range.
What is the power of the pump in the Glow-worm Jaguar 23 kW?
0.36 A / 83 W at 230V-50Hz, according to the label of another unit of the same product.
Is this pump also suitable for a 'Saunier Duval Hermann'?
That name does not appear on the verified list of compatible models for this part.

Spare parts related to Renova Protherm

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model