Wilo Circulating Pump VASL15/6-2-HE For Vaillant VMW 242/2-5 - Ref. 160928
Refurbished Vaillant Pumps Wilo

Wilo Circulating Pump VASL15/6-2-HE For Vaillant VMW 242/2-5 - Ref. 160928

Wilo VASL15/6-2-HE circulator pump, factory-installed in Vaillant VMW, VU, and VUW boilers of series 2-5. It moves water in the circuit for heating and domestic hot water. The replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler does not heat despite the burner igniting, makes excessive noise, or gets blocked due to a fault in the pump.

Type of part
Pumps
Catalogue reference
160928
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Vaillant boilers compatible with reference 160928

Circulating pump with reference 160928. 26 verified compatibilities: VM 240 and VM 242.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VM 240VM (heating only)Contrasted
Vaillant VM 242VM (heating only)Contrasted
Vaillant VM 280VM (heating only)Contrasted
Vaillant VM 282VM (heating only)Contrasted
Vaillant VMW 240VMW (combi)Contrasted
Vaillant VMW 242VMW (combi)Contrasted
Vaillant VMW 280VMW (combi)Contrasted
Vaillant VMW 282VMW (combi)Contrasted
Vaillant VMW ES 240VMW (combi)Contrasted
Vaillant VMW ES 242VMW (combi)Contrasted
Vaillant VU 240VU / VUWContrasted
Vaillant VU 242VU / VUWContrasted
Vaillant VU 280VU / VUWContrasted
Vaillant VUW 240VU / VUWContrasted
Vaillant VUW 242VU / VUWContrasted
Vaillant VUW 280VU / VUWContrasted
Vaillant Plus 824ETurboMaxContrasted
Vaillant Plus 828ETurboMaxContrasted
Vaillant Plus 837ETurboMaxContrasted
Vaillant Pro 24ETurboMaxContrasted
Vaillant Pro 28ETurboMaxContrasted
Vaillant 615EThermocompactContrasted
Vaillant 620EThermocompactContrasted
Vaillant 624EThermocompactContrasted
Vaillant 628EThermocompactContrasted
Vaillant 637EThermocompactContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 160928 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 160928. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulation pump 160928

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler ignites the burner, but the water in the radiators does not heat up.

    Cause: The burner is working well, but the pump is not circulating water through the circuit.

    Touch the supply and return heating pipes: if one is hot and the other is cold, the pump is to blame.

  • 02

    The pump makes a loud noise or vibrates when operating.

    Cause: The impeller may be partially blocked or the shaft worn, which is common after extensive use.

    Listen to see if the noise changes when adjusting the pump speed; if it persists at all speeds, the problem lies with the shaft or the impeller.

  • 03

    Moisture or dripping appears in the area where the pump connects to the boiler.

    Cause: The mechanical seal of the shaft wears out over time and starts to leak water.

    Dry the area well and check in cold if the leak reappears before changing the pump; sometimes it's just a loose gasket.

  • 04

    The boiler display shows a fault code related to the pump or circulation.

    Cause: The electronics detect that the flow or pressure sensor does not sense water movement.

    Note the exact code and check it in the manual before purchasing; some circulation errors are due to air in the circuit, not the pump.

Vaillant fault codes that require diagnosis

CodeFaultTechnical checks
F.75When the pump starts, a sufficient pressure increase is not detected.The circulation pump 160928 blocked/faulty does not generate the pressure increase that the sensor should register; check that the pump rotates and consumes, and that test P.0 shows Δp at start-up.
F.23Excessive flow-return temperature difference (insufficient circulation).If the pump does not circulate flow, the supply heats up quickly and the return remains cold, causing a large ΔT; check the pump's performance/speed (D.14/D.19), temperatures, and bleed/filter of the hydraulic block.
F.24Temperature increase too rapid.With the pump blocked or with low performance, the water does not circulate and the boiler temperature rises quickly; check the pump rotation and consumption, bleed the circuit, and check pressure/flow rate.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Vaillant 160928 circulation pump.

Catalogue reference
160928
Uniclima internal SKU
BCTES242
Brand
Vaillant
Type of part
Pumps
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Condenser
2.6 µF - 400V DB
Voltage
230V ~ 50Hz
Speed
Speed II: 2320 min-1 / Speed III: 2180 min-1
Current
0.39 A (speed II) / 0.27 A (speed III)
Power
87 W (speed II) / 60 W (speed III)
Nominal Pressure / IP Rating
PN6 - IP44
Thermal class
Class F - TF95
Manufacturer code (Wilo)
VASL15/6-2-HE - refs. 4513296 and 4511547 - unit code 160952
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the circulator pump 160928

Which manufacturer makes the pump for the Vaillant VMW 242/2-5 with Ref. 160928?
Wilo, model VASL15/6-2-HE, according to the part label.
Is this Wilo pump compatible with the VU range boilers?
Yes, the Wilo VASL15/6-2-HE pump is compatible with the models from the VU range, such as VU 240, VU 242, and VU 280.
What capacitor does the Wilo VASL15/6-2-HE pump use?
A 2.6 µF - 400V DB capacitor, according to the label.
What speeds does this Vaillant 2-5 series pump have?
Two speeds: II (2320 min-1) and III (2180 min-1), according to the label.
When should this pump be replaced in a Vaillant VM 242/2-5?
The technical diagnosis must confirm that it is necessary to replace it, even when the boiler does not heat despite the burner igniting, makes excessive noise, or becomes blocked due to a pump failure.
What is the reference for the Wilo pump compatible with the Vaillant VMW 242/2-5?
BCTES242 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.

Spare parts related to Vaillant VMW (combi)

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Wilo Circulating Pump VASL15/6-2-HE For Vaillant VMW 242/2-5 - Ref. 160928