Emmeti Safety Valve for Fagor Boiler FE-24AE-1N
Safety valve set at 3 bar, compatible with Fagor boilers FE-24AE-1N, FE-24E-1N, FE-24NOX-1N, FE-24TC-1N, and FE-30AE-1N. The component is manufactured by Emmeti, an Italian plumbing and heating brand, different from Fagor. It releases water or steam from the circuit when the pressure exceeds the setting, protecting the boiler from overpressure. It should be replaced if it continuously drips or does not activate at 3 bar.
VAT included
Consult via WhatsAppCompatible Fagor boilers
Safety valve. Five confirmed compatibilities: FE-24AE-1N and FE-24E-1N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE-24AE-1N | FE-24AE-1N | Contrasted |
| Fagor FE-24E-1N | FE-24E-1N | Contrasted |
| Fagor FE-24NOX-1N | FE-24NOX-1N | Contrasted |
| Fagor FE-24TC-1N | FE-24TC-1N | Contrasted |
| Fagor FE-30AE-1N | FE-30AE-1N | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the safety valve resolves
The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The valve is leaking continuously even when the boiler is turned off.
Cause: The seat does not seal properly, usually due to limescale or a small trapped particle.
Pull the bleed lever a couple of times to try to clean the seat before replacing it.
- 02
It occasionally releases water for no clear reason.
Cause: It is possible that the gas valve is correctly releasing occasional pressure spikes when heating the circuit.
Note the cold and hot pressure during a couple of cycles to check if it approaches 3 bar before suspecting the gas valve.
- 03
It is suspected that the circuit is overpressurized because the valve discharges more often than usual.
Cause: An expansion vessel without air pressure causes the circuit to rise suddenly, and the valve has to work harder.
Check the air pressure of the expansion vessel with the boiler empty before considering the valve as faulty.
- 04
The dripping appears right after refilling the water circuit.
Cause: If it is filled above the normal pressure, the valve opens to return the circuit to a safe level.
Check the pressure indicated by the pressure gauge after filling; if it exceeds 1.5-2 bar when cold, lower the pressure before checking the valve.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor safety valve
- Brand
- Fagor
- Type of part
- Safety valves
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- fool
- 3 bar
- Component manufacturer
- EMMETI
- The actual manufacturer of the valve is Emmeti, different from Fagor (the boiler brand): it is not an "original Fagor" part.