3 Bar Safety Valve Hermann Micra Condens 26 Ref. H155600002

3 Bar Safety Valve Hermann Micra Condens 26 Ref. H155600002

If you notice that your boiler is leaking continuously, a technical diagnosis must confirm whether you need the 3 Bar Safety Valve Hermann Micra Condens 26 Ref. H155600002. This valve is responsible for releasing water when the circuit pressure exceeds 3 bar, preventing damage to the system. If it fails, it does not discharge properly or may present leaks. It is compatible with the Micra Condens range, including the Micra Condens 26 model, among others. A technician must confirm through diagnosis whether it needs to be replaced when constant dripping or pressure issues are observed.

Type of part
Safety valves
Catalogue reference
H155600002
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Hermann boilers compatible with reference H155600002

Safety valve with reference H155600002. A proven compatibility: Micra Condens 26.

Proven compatibility

Boiler modelFamilyVerification
Hermann Micra Condens 26Micra CondensContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. H155600002 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference H155600002. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the safety valve H155600002

The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    It drips or bleeds intermittently from the discharge pipe.

    Cause: The seat does not close completely due to accumulated scale or a small residue of dirt in the interior passage.

    Operate the bleed lever a couple of times to try to clean the seat before replacing the part.

  • 02

    The valve opens just when the circuit approaches 3 bar, even during normal use.

    Cause: If the expansion vessel does not properly cushion the pressure increase, the circuit reaches the set limit sooner than expected.

    Measure the air pressure of the expansion vessel with the boiler cold and empty before suspecting the gas valve.

  • 03

    It's difficult to maintain a stable pressure in the circuit: it rises and falls easily.

    Cause: A valve that starts to fail releases small amounts of water each time the pressure rises, without visibly dripping.

    Monitor the pressure gauge during a complete heating cycle and note if the pressure decreases progressively after each increase.

  • 04

    A ring of moisture or dry lime appears around the discharge pipe.

    Cause: It is a sign that the valve has been leaking intermittently for some time, even though no active water is visible now.

    Clean the area and check it again after a few days: if the stain reappears, confirm that the leak is still active.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the safety valve Hermann H155600002

Catalogue reference
H155600002
Uniclima internal SKU
VSMHMC26
Brand
Hermann
Type of part
Safety valves
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Set pressure
3 bar
Nominal Pressure (PN)
PN 10
Frequently Asked Questions

Frequently asked questions about the safety valve H155600002

At what pressure does the safety valve Ref. H155600002 open for the Hermann Micra Condens 26 boiler?
Open to 3 bar, as indicated on the part's label.
What nominal pressure can the body of this valve withstand?
It supports a nominal pressure of PN 10, engraved on the inner disc of the part.
Is this safety valve compatible with other Hermann boiler models?
The safety valve VSMHMC26 is compatible only with the Micra Condens 26 boiler.
What is the reference for the safety valve for the Hermann Micra Condens 26?
VSMHMC26 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
Are there documented fault codes for this gas valve?
No, there are no documented fault codes for this product.

Spare parts related to Hermann Micra Condens

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
3 Bar Safety Valve Hermann Micra Condens 26 Ref. H155600002