Safety Valve For Thema C 23 And Themaplus F 23 E - Ref. 05726600
The safety valve releases water if the circuit pressure exceeds the usual limit of 3 bar. When it fails, it may leak continuously or not discharge when it should, which can cause problems in the operation of the boiler. This model is compatible with boilers Thema C 23 E, Thema F 23 E, Themaplus C 23 E, Themaplus F 23 E, among others. It is recommended to replace it if you notice any of these symptoms to avoid further damage to the system.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference 05726600
Safety valve with reference 05726600. Six confirmed compatibilities: Thema C 23 E and Thema F 23 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Thema C 23 E | Thema | Contrasted |
| Saunier Duval Thema F 23 E | Thema | Contrasted |
| Saunier Duval Themaplus C 23 E | Themaplus | Contrasted |
| Saunier Duval Themaplus F 23 E | Themaplus | Contrasted |
| Saunier Duval Combitek C 23 E | Combitek | Contrasted |
| Saunier Duval Combitek F 23 E | Combitek | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 05726600 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 05726600. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the safety valve 05726600 resolves.
The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The valve suddenly releases water and empties part of the circuit, and then the system needs to be refilled.
Cause: If the seat does not close properly after firing, it continues to drain water even though the pressure is normal.
After a discharge, check if the dripping continues once the pressure has returned to its normal value; if it doesn't stop, the seat is not closing.
- 02
A ring of dry lime appears under the discharge pipe, although it is not dripping at the moment.
Cause: Indicate that the valve has released water at some point earlier, usually due to a pressure spike in the circuit.
Check the date of the last maintenance of the boiler; an isolated pressure spike doesn't always mean the valve is faulty.
- 03
The pressure gauge shows a normal pressure, but occasionally a brief spurt comes out of the pipe.
Cause: Lime deposits on the seat can prevent a perfect seal and allow small amounts of water to pass intermittently.
Bleed the air from the radiators: the accumulated air in the circuit can also cause pressure spikes that activate the valve without it being faulty.
- 04
The manual bleed lever or button is stiff and difficult to move.
Cause: The mechanism may have seized due to lack of use or internal deposits, preventing it from opening when necessary.
With the system cold, carefully operate the manual bleed; if it doesn't give way with moderate pressure, do not force it and consider replacing it.
- 05
It makes a fine whistling sound next to the valve when the boiler is running.
Cause: A small passage of water or air through a seat that doesn't close completely generates that characteristic whistling sound.
Wipe the body of the valve and the discharge pipe with a dry cloth to locate if there is moisture right at the point of the noise.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval safety valve 05726600
- Catalogue reference
- 05726600
- Brand
- Saunier Duval
- Type of part
- Safety Valves
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days