Elbi 3-Way Valve Motor for Biasi Myto Condens 24 - Ref. 31600010.00
Motor that drives the boiler's three-way valve, the part that distributes water between heating and domestic hot water. Manufactured by Elbi, with motor code 31600010.00 confirmed on the label and by two external sources. It is replaced when the boiler stops switching between the two circuits or the motor does not turn.
VAT included
Consult via WhatsAppBiasi boilers compatible with reference BI1431100
3-way valve with reference BI1431100. 11 verified compatibilities: MIDAS 24E and MIDAS 28E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi MIDAS 24E | MIDAS | Contrasted |
| Biasi MIDAS 28E | MIDAS | Contrasted |
| Biasi MIDAS 32E | MIDAS | Contrasted |
| Biasi MIDAS ECO 24E | MIDAS | Contrasted |
| Biasi MIDAS ECO 28E | MIDAS | Contrasted |
| Biasi MYTO CONDENS 24 | MYTO CONDENS | Contrasted |
| Biasi MYTO CONDENS 35 | MYTO CONDENS | Contrasted |
| Biasi MYTO CONDENS PLUS 24 | MYTO CONDENS | Contrasted |
| Biasi MYTO CONDENS PLUS 35 | MYTO CONDENS | Contrasted |
| Biasi MYTO CONDENS INOX 24 | MYTO CONDENS | Contrasted |
| Biasi MYTO CONDENS INOX 35 | MYTO CONDENS | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. BI1431100 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI1431100. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the BI1431100 three-way valve resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The heating works well but there is no domestic hot water, or vice versa.
Cause: The Elbi motor has not fully turned to the correct circuit and the water remains in the previous mode.
Check if the motor moves when requesting domestic hot water: sometimes it is enough to see if it spins completely or stops halfway.
- 02
The motor gets stuck, makes noise, or doesn't turn at all when switching modes.
Cause: The wear of the gear or the scale buildup on the shaft can prevent the motor from completing its travel.
With the boiler unplugged, try to manually move the motor shaft to see if it is seized before considering the part lost.
- 03
The boiler displays a fault code related to the three-way valve and locks out.
Cause: If the motor does not confirm its final position, the PCB understands that there is a fault and interrupts the cycle for safety.
Check the boiler manual for the specific fault code that has been triggered and see if it specifically corresponds to the three-way valve, not another component.
- 04
The switch between heating and domestic hot water occurs with a significant delay.
Cause: A motor that runs slower than normal due to internal wear takes longer to complete the commutation.
Time it a couple of times to see how long it takes to switch modes: if the time is consistently much longer than one or two seconds, it points to a sluggish motor, not the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the 3-way valve Biasi BI1431100
- Catalogue reference
- BI1431100
- Brand
- Biasi
- Type of part
- 3-way valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- Elbi
- Engine code
- 31600010.00
- Secondary code
- 4028.8050.07 / 40288060.07
- Temperature class
- T70
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Manaut MYTO CONDENS PLUS 35 Manual (PDF)Document © Biasi, provided as a technical reference.