Hydraulic Group With 3-Way Valve Junkers/Bosch ZWBC30-2 C23 Ref. 8716106356
When you turn on the hot water tap or activate the heating, the hydraulic group with the Junkers/Bosch ZWBC30-2 C23 three-way valve is responsible for directing the flow of water between the heating circuit and the domestic hot water circuit. If this valve fails, you may notice that you have hot water but no heating, or vice versa, and there could even be a mixing of both circuits. This group is installed in various boilers, such as the ZWB25-2C23, ZWB32-2, ZWBC24-2C23, and ZWBE30-3C23, among others. It is important to replace it when you start experiencing these issues to ensure comfort in your home.
VAT included
Consult via WhatsAppJunkers boilers compatible with reference 8716106356
3-way valve with reference 8716106356. 29 verified compatibilities: ZSB30-2E23 and ZSB30-2E31.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Junkers ZSB30-2E23 | ZSB30-2E23 | Contrasted |
| Junkers ZSB30-2E31 | ZSB30-2E31 | Contrasted |
| Junkers ZWB25-2C23 | ZWB25-2C23 | Contrasted |
| Junkers ZWB25-2C31 | ZWB25-2C31 | Contrasted |
| Junkers ZWB32-2 | ZWB32-2 | Contrasted |
| Junkers ZWB42-2E23 | ZWB42-2E23 | Contrasted |
| Junkers ZWB42-2E31 | ZWB42-2E31 | Contrasted |
| Junkers ZWBC24-2C23 | ZWBC24-2C23 | Contrasted |
| Junkers ZWBC24-2C31 | ZWBC24-2C31 | Contrasted |
| Junkers ZWBC25-2C23 | ZWBC25-2C23 | Contrasted |
| Junkers ZWBC25-2C31 | ZWBC25-2C31 | Contrasted |
| Junkers ZWBC28-2C23 | ZWBC28-2C23 | Contrasted |
| Junkers ZWBC28-2C31 | ZWBC28-2C31 | Contrasted |
| Junkers ZWBC30-2C23 | ZWBC30-2C23 | Contrasted |
| Junkers ZWBC30-2C31 | ZWBC30-2C31 | Contrasted |
| Junkers ZWBE25-3C23 | ZWBE25-3C23 | Contrasted |
| Junkers ZWBE25-3C31 | ZWBE25-3C31 | Contrasted |
| Junkers ZWBE30-3C23 | ZWBE30-3C23 | Contrasted |
| Junkers ZWBE30-3C31 | ZWBE30-3C31 | Contrasted |
| Junkers ZWBE32-2A23 | ZWBE32-2A23 | Contrasted |
| Junkers ZWBE32-2A31 | ZWBE32-2A31 | Contrasted |
| Junkers ZWBE37-2A23 | ZWBE37-2A23 | Contrasted |
| Junkers ZWBE37-2A31 | ZWBE37-2A31 | Contrasted |
| Junkers ZWBE42-2A23 | ZWBE42-2A23 | Contrasted |
| Junkers ZWBE42-2A31 | ZWBE42-2A31 | Contrasted |
| Junkers ZWN25-8MFA23 | ZWN25-8MFA23 | Contrasted |
| Junkers ZWN25-8MFA31 | ZWN25-8MFA31 | Contrasted |
| Junkers ZWN30-8MFA23 | ZWN30-8MFA23 | Contrasted |
| Junkers ZWN30-8MFA31 | ZWN30-8MFA31 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 8716106356 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 8716106356. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the 3-way valve 8716106356 resolves.
The 3-way valve diverts water between heating and domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
There is no hot water coming out of the tap, or it takes a long time to come out, although the heating is working fine.
Cause: The valve does not switch to the domestic hot water circuit and the water continues to circulate only for heating.
Open a hot water tap and listen for the click of the gas valve motor when the demand starts; if it doesn't move, it could be the motor or the microswitch and not the valve body.
- 02
The water comes out mixed, neither completely cold nor completely hot, from the hot water tap.
Cause: The valve does not close the heating flow properly, and some water leaks into the wrong circuit.
Measure the supply and return temperature of the heating system with the hot water tap open: if the return drops significantly, the valve is allowing water to flow through both paths at the same time.
- 03
There is a puddle or pool of water under the hydraulic group, near the gas valve.
Cause: The O-rings in the body dry out or crack over time and start to leak from there.
Dry the area well, start the boiler, and locate the exact point of the drip before considering the entire part good: sometimes it's a flange or a nearby fitting, not the gas valve.
- 04
The boiler takes too long to switch from heating to domestic hot water, as if it is taking time to process.
Cause: The valve mechanism gets stuck with limescale deposits, and the motor requires more power and time to move it.
If the boiler has not been used for months for hot water, turn the tap on and off several times in a row: if it improves with use, it is scale and not a definitive fault.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Junkers 8716106356 three-way valve.
- Catalogue reference
- 8716106356
- Brand
- Junkers
- Type of part
- 3-way valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Component reference
- 8716106356
- Component manufacturer
- Junkers/Bosch (2 external sources)
- Position in the hydraulic group
- Left side
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Junkers ZWBC30-2C31 manual (PDF)Document © Junkers, provided as a technical reference.