Saunier Duval ThemaClassic F25E Drain Tap Ref. S1006300
The Saunier Duval ThemaClassic F25E drain valve is a filling key that allows water to be replenished in the heating circuit to recover the necessary pressure. When it fails, the user notices that they cannot refill the circuit or that the valve continuously leaks water, which can lead to an unwanted increase in pressure. This valve is compatible with various Saunier Duval boilers, such as the ThemaClassic C 24 E, ThemaClassic F 24 E, among others. A technician must confirm through diagnosis whether it needs to be replaced when it shows leaks or does not allow the circuit to be filled.
- Type of part
- Drain valves
- Status
- Refurbished
- Catalogue reference
- S1006300
- Warranty
- 1 year
Saunier Duval boilers compatible with reference S1006300
Drain keys with reference S1006300. 22 verified compatibilities: ThemaClassic C 24 E and ThemaClassic C 25 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval ThemaClassic C 24 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic C 25 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic F 24 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic F 25 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic C AS 24 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic C AS 25 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic F AS 24 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic F AS 25 E | Saunier Duval | Contrasted |
| Saunier Duval ThemaClassic F AS 30 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast C 24 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast C 28 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast F 24 E | Saunier Duval | Contrasted |
| Saunier Duval Themafast F 30 E | Saunier Duval | Contrasted |
| Saunier Duval Thematek C 24 E | Saunier Duval | Contrasted |
| Saunier Duval Thematek F 24 E | Saunier Duval | Contrasted |
| Saunier Duval Thematek SC 24 E | Saunier Duval | Contrasted |
| Saunier Duval Thematek SF 24 E | Saunier Duval | Contrasted |
| Saunier Duval Thematek C 24 EO BT | Saunier Duval | Contrasted |
| Saunier Duval Themaplus C 24 E | Saunier Duval | Contrasted |
| Saunier Duval Themaplus F 24 E | Saunier Duval | Contrasted |
| Saunier Duval Thema C 24 E | Saunier Duval | Contrasted |
| Saunier Duval Thema F 24 E | Saunier Duval | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S1006300 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S1006300. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the drain valves S1006300
Common symptoms and faults
- 01
The drain tap drips constantly even when it is closed.
Cause: The internal seat does not seal completely and allows water from the circuit to leak out.
Check that it is turned all the way to the closed position before declaring the part defective.
- 02
It is difficult to open it when it is necessary to drain the boiler for a repair.
Cause: The mechanism gets stuck due to limescale and because it has not been operated for a long time.
Try to open it with an appropriate key without excessive force; when cold, the body can break.
- 03
Water keeps coming out after closing the tap following the circuit drain.
Cause: The hose fitting or the internal seat is worn and does not properly cut off the flow.
Check if the drain hose fitting is tightened properly; sometimes the leak comes from there and not from the tap itself.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Saunier Duval S1006300 drain keys
- Catalogue reference
- S1006300
- Uniclima internal SKU
- LLDVSD
- Brand
- Saunier Duval
- Type of part
- Drain valves
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Raised code on the plastic body
- 4511596
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Themaclassic F 25 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.