Expansion Vessel Chaffoteaux Niagara Delta 30 FF
- Delivery to the EU in 2–6 working days · Depending on the country; cost shown at checkout
- Returns within 14 days, spare part not installed
- Inspected and tested, warranty 1 year
Is it compatible with your boiler?
Chaffoteaux boilers compatible with this spare part
- Delta 24 FFAludra
- Delta 28 FFAludra
- 2.23 FFCalydra
- 2.28 FFCalydra
- 1.16 RSCCeltic
- 2.24 FFCentora
- Comfort 24 FFElexia
- 2.23 FFNectra
- Delta 30 FFNiagara
Can’t see your model? The printed reference takes priority. How to check it or send us a photo on WhatsApp.
How to check if this spare part is the one for your boiler
-
Look for the reference on your vessel
It is usually on a label or screen-printed on it. If it is not legible, do not work it out from its shape.
-
Find the model of your boiler
It is on the rating plate. Look it up in the compatible list.
-
Compare connections and body
With the original spare part, before fitting.
-
If you are unsure, send us a photo
For the screen print: we will confirm it with you before you buy.
Send photo via WhatsApp
Symptoms that require diagnosis on this spare part (expansion vessel)
The circuit is gradually losing pressure, and you have to refill more frequently than usual
- Cause
- The vessel has lost its air charge or has a leak in the membrane and no longer retains the pressure that it should maintain in the circuit
- What to do
- Measure the pre-charge pressure of the vessel when cold and without water in the circuit: the label on this part indicates a setting of 3 bar, so if it measures well below that, it confirms the loss
The safety valve is leaking or repeatedly discharging water, especially when the boiler is running
- Cause
- If the expansion vessel does not absorb the expansion of the hot water, the pressure rises until the safety valve releases it
- What to do
- Before changing the expansion vessel, check that the safety valve is not simply dirty or damaged at its seat; a valve that does not close properly will leak just the same with a vessel in good condition
The glass sounds full, without the characteristic air gap, when tapped with the hand
- Cause
- A broken membrane allows water to pass to the air side, and the vessel ends up behaving like an additional section of filled pipe
- What to do
- With the depressurized system, tap the tank at different points; if the sound is uniform and solid across the entire surface, there is no air inside
The pressure rises significantly just when starting the heating and drops when it stops
- Cause
- It is the typical signature of a vessel without expansion capacity: all the volume of water that expands goes directly to circuit pressure
- What to do
- Compare the cold pressure with the pressure a few minutes after operation; a large and repeated difference points to the expansion vessel, although it is advisable to rule out excessive filling first
Electrical work and opening the boiler are jobs for a technician. Repair and diagnosis
Technical sheet: expansion vessel Chaffoteaux
Expansion vessel Chaffoteaux Niagara Delta 30 FF, reference 60056676-06. This component is responsible for absorbing the increase in water volume when heated. If it has faults, such as loss of pressure or a broken diaphragm, you will notice that the boiler pressure fluctuates sharply, and the safety valve may leak. It is compatible with boilers from the Aludra, Calydra, Celtic, Centora, Elexia, and Nectra ranges, among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms are detected to avoid further issues.
Spare part details
- Set pressure
- 3 bar
Check the reference and label details against the spare part you have installed: two similar references are not always equivalent. Technical sheet reviewed on .
Frequently asked questions about the spare part expansion vessel Chaffoteaux
Is this expansion vessel suitable for a Chaffoteaux Elexia Comfort 24 FF?
Yes, it is on the list of compatible boilers along with the models from the Aludra, Calydra, Celtic, Centora, Nectra, and Niagara ranges.
What pressure is the expansion vessel of the Niagara Delta 30 FF set to?
The label confirms a set pressure of 3 bar.
When should the expansion vessel of the Celtic 1.16 RSC be replaced?
It should be checked when it loses pressure or leaks from the safety valve. Replacement requires a technical diagnosis.
What is the reference for the expansion vessel for the Niagara Delta 30 FF?
The reference is VDEND30FF.
How many boiler models are compatible with the expansion vessel VDEND30FF?
There are a total of 9 confirmed models.
Is this expansion vessel compatible with the Chaffoteaux Nectra 2.23?
Yes, the expansion vessel is compatible with the Chaffoteaux Nectra 2.23.
What does it mean that this spare part (vessel) is reconditioned?
That it is not a new spare part: it is sold inspected and tested, with a 1-year warranty. If in the end you do not install it, you have 14 days to return it.
How much does shipping cost and how long does it take to arrive?
TIPSA shipping: 24/48 working hours to mainland Spain and 2–6 working days to the EU, depending on the country. No shipping to the Balearic or Canary Islands, Ceuta or Melilla.
The exact cost appears in your cart before you pay. Check delivery times and shipping rates by country.
Can I return it if it turns out not to be the right spare part for me?
Yes. You have 14 calendar days from when you receive it to return this spare part vessel, provided it is uninstalled, unused and in its original packaging. The return shipping is at your expense, unless the error was ours or the spare part arrives faulty.
The exception is electronic boards and electronic components, for which returns are not accepted: they are inspected and prepared for a specific appliance and, once connected, their condition cannot be checked. Read the returns policy.