Chaffoteaux MC FF Extractor - FIME Motor L39R7535 CLH - Ref. 61010212
FIME smoke extractor fan, model L39R7535 CLH, made in Italy, for Chaffoteaux boilers in the MC FF range and equivalents (Calydra, Centora, Elexia, Hyxia, Maya, Nectra, Siam FF, among others). Powered by 220-240 V at 50 Hz. It is replaced when the extractor does not start, makes abnormal noise, or the boiler locks due to smoke extraction failure.
VAT included
Consult via WhatsAppCompatible Chaffoteaux boilers
Extractor. 14 confirmed compatibilities: SYSTEM / BRITONY COMBI (various models) and 23 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux SYSTEM / BRITONY COMBI (various models) | BRITONY | Contrasted |
| Chaffoteaux 23 FF | CALYDRA | Contrasted |
| Chaffoteaux COMFORT 24 FF | CALYDRA | Contrasted |
| Chaffoteaux 2.24 FF | CENTORA | Contrasted |
| Chaffoteaux COMFORT 24 FF | ELEXIA | Contrasted |
| Chaffoteaux II 2.23 FF | ELEXIA | Contrasted |
| Chaffoteaux 23 FF | HYXIA | Contrasted |
| Chaffoteaux 24 FF | MAYA | Contrasted |
| Chaffoteaux 2 24 FF | MC | Contrasted |
| Chaffoteaux FF | MC | Contrasted |
| Chaffoteaux 2.23 FF | NECTRA | Contrasted |
| Chaffoteaux 3.23 FF | NECTRA | Contrasted |
| Chaffoteaux TOP 2.23 FF | NECTRA | Contrasted |
| Chaffoteaux 2.23 FF | SIAM | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the extractor resolves
The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler tries to ignite and shuts off immediately, before the flame appears.
Cause: If the extractor does not spin correctly, the air pressure switch does not close, and the control board cuts the cycle for safety.
Check if the fan starts at the same moment the boiler requests ignition; if it delays, suspect it.
- 02
The extractor does not start at all; it remains silent.
Cause: This motor operates at 220-240 V and 50 Hz, and a fault in the winding or in the power supply prevents it from rotating.
Measure with a multimeter to check if there is current at the motor connector before declaring it faulty.
- 03
Abnormal noise or noticeable vibration when the extractor is running.
Cause: It is typical of bearing wear or a turbine that has lost balance with use.
Try turning the shaft by hand, with the boiler unplugged, to see if there is any friction or excessive play.
- 04
The boiler is blocking, indicating a flue gas extraction fault.
Cause: The extractor does not generate the minimum depression that the system needs to validate combustion.
Before replacing it, check that the exhaust pipe is not crushed, disconnected, or has a slope that retains condensate water.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Chaffoteaux extractor datasheet
- Brand
- Chaffoteaux
- Type of part
- Extractors
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Motor code (FIME)
- L39R7535 CLH
- Place of manufacture
- Made in Italy
- Voltage
- 220-240 V~ (last digit not entirely legible)
- Frequency
- 50 Hz
- Power
- 25 W
- Certification
- CE
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Chaffoteaux TOP 2.23 FF Manual (PDF)Document © Chaffoteaux, provided as a technical reference.