Fagor Boiler Fan Extractor FEB 23E N Ref. AS0013067

Fagor Boiler Fan Extractor FEB 23E N Ref. AS0013067

Stock · 3 units

The fan extractor of the Fagor FEB 23E N boiler, reference AS0013067, is responsible for expelling combustion gases and creating the necessary draft for the boiler to start. When it fails, the boiler does not ignite or gets locked, displaying the fault code F-2: air pressure switch does not detect air circulation. This fan is compatible with models such as FE24E, FE24E1N, FE24NOX, and FEB24AR, among others in the Fagor FE, FEB, and CE 24 range. It should be replaced when ignition problems or lockouts due to flue gas evacuation failure are detected.

VAT included

Compatibility

Fagor boilers compatible with reference AS0013067

Extractor with reference AS0013067. Four confirmed compatibilities: FE24E and FE24E1N.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE24EFagor FE / FEB / CE 24 (24 kW sealed atmospheric)Contrasted
Fagor FE24E1NFagor FE / FEB / CE 24 (24 kW sealed atmospheric)Contrasted
Fagor FE24NOXFagor FE / FEB / CE 24 (24 kW sealed atmospheric)Contrasted
Fagor FEB24ARFagor FE / FEB / CE 24 (24 kW sealed atmospheric)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. AS0013067 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference AS0013067. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the extractor AS0013067 resolves.

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The extractor does not start and the boiler does not ignite.

    Cause: The motor does not reach the minimum revolutions necessary for the control board to allow the gas flow.

    With the boiler unplugged, check if the turbine spins freely by hand or if it is stuck.

  • 02

    There is an excessive noise or vibration from the extractor while it is operating.

    Cause: This is usually due to accumulated dirt in the turbine that unbalances it, or due to a worn bearing.

    Check if the extractor blades are dirty or blocked with soot before considering the part as faulty.

  • 03

    The boiler is locking out or showing a fan error on the display.

    Cause: The control board does not detect the correct rotation of the fan and cuts off the ignition for safety.

    Check that the extractor starts when the power is turned on (you should notice or hear a buzzing) before replacing it.

  • 04

    The extractor seems to be working, but the combustion is not stabilizing or it smells strange near the flue outlet.

    Cause: If the extractor does not provide the adequate air flow, the combustion mixture becomes unbalanced even though the motor is running.

    Check that the flue pipe is not blocked from the outside; this symptom is easily confused with a fault in the fan.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F-2Air pressure switch does not detect air circulation (or fault in the pressure switch itself); the boiler locks out.Faulty extractor/fan or lack of flow does not generate the necessary depression and the pressure switch does not switch, triggering F-2; check power supply to the fan at start-up, free rotation/noise, and that the pressure switch changes state with the fan running.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Fagor AS0013067 extractor datasheet

Catalogue reference
AS0013067
Brand
Fagor
Type of part
Extractor fans
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Frequently Asked Questions

Frequently asked questions about the extractor AS0013067

Does this extractor Ref. AS0013067 work for a boiler FEB23E?
Yes, the FEB23E is on the list of compatible boilers for this part, along with FE24E, FE24E1N, FE24NOX, and FEB24AR.
What fault of the boiler FEB24AR does changing this fan resolve?
It is replaced when it does not start, makes excessive noise, or the boiler is blocked due to a fan fault.
What is the purpose of the extractor in the FE24E boiler?
It expels combustion gases during burner operation.
How many models are compatible with the extractor Ref. AS0013067?
There are a total of 4 compatible models.
What fault code is documented for this extractor?
The documented fault code is F-2.
Where can I find more information about this extractor?
You can refer to the ECFF2001 reference for more details about the part.

Spare parts related to Fagor Fagor FE / FEB / CE 24 (24 kW sealed atmospheric)

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Fagor Boiler Fan Extractor FEB 23E N Ref. AS0013067