Fagor Contract Mini CE 30 E Extractor Ref. AS0013067
The Fagor Contract Mini CE 30 E extractor is a flue fan responsible for evacuating combustion gases and generating the necessary draft for the boiler to start. When this part fails, the boiler does not ignite or gets locked, potentially displaying the fault code F-2 due to a failure in air circulation detection. This extractor is compatible with boilers from the Fagor FE / FEB / CE 24 range, such as the models FE24E, FE24E1N, and FEB24AR, among others. It is recommended to replace it when ignition problems or frequent lockouts occur.
VAT included
Consult via WhatsAppFagor boilers compatible with reference AS0013067
Extractor with reference AS0013067. Four confirmed compatibilities: FE24E and FE24E1N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE24E | Fagor FE / FEB / CE 24 (24 kW sealed atmospheric) | Contrasted |
| Fagor FE24E1N | Fagor FE / FEB / CE 24 (24 kW sealed atmospheric) | Contrasted |
| Fagor FE24NOX | Fagor FE / FEB / CE 24 (24 kW sealed atmospheric) | Contrasted |
| Fagor FEB24AR | Fagor FE / FEB / CE 24 (24 kW sealed atmospheric) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. AS0013067 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference AS0013067. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the extractor AS0013067 resolves.
The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and shows a fault related to the extractor or ventilation.
Cause: The control unit blocks the ignition of the burner if it does not receive the signal that the fan is rotating correctly.
Check if the fan starts when the boiler is turned on or if it remains stationary before replacing it.
- 02
The extractor starts but struggles to reach speed, as if it lacks power.
Cause: A worn motor or one with damaged bearings does not achieve the necessary rotation to generate the appropriate depression.
Unplug the boiler, manually turn the shaft of the fan, and check if you feel any abnormal resistance.
- 03
There is a louder than normal noise, like a buzzing or rubbing sound, when the boiler is on.
Cause: A worn or misaligned impeller can rub against the casing while rotating, causing that noise.
Visually check if the impeller is off-center or if there are rubbing marks on the casing.
- 04
The boiler intermittently locks out due to flue gas failure, sometimes it does and sometimes it doesn't.
Cause: A faulty extractor does not always lose flow in the same way, so the fault may not repeat with each attempt.
Before changing the part, check that the flue pipe is properly installed and free of obstructions, as it can cause the same symptom.
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F-2 | Air pressure switch does not detect air circulation (or fault in the pressure switch itself); the boiler locks out. | Faulty extractor/fan or lack of flow does not generate the necessary depression and the pressure switch does not switch, triggering F-2; check power supply to the fan at start-up, free rotation/noise, and that the pressure switch changes state with the fan running. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Fagor AS0013067 extractor datasheet
- Catalogue reference
- AS0013067
- Brand
- Fagor
- Type of part
- Extractor fans
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Complete screen printing
- RLE130234A00 A18- | 26X0LH.A5G P26 | 230V ~ 50Hz A250 | TMAX I CL.H CH.U.1
- Voltage
- 230V
- Frequency
- 50Hz