Caleffi Filling Valve for Wolf Boiler CGB K24 Ref. 2070268
Filling valve that allows water to be added to the boiler's heating circuit. The brass body has the label 'CALEFFI' with flow direction arrows, identifying the actual manufacturer of the component. Fits Wolf boilers CGB K20, CGB K24, CGB K40-35, and CGW 24/140. It does not have any model code or additional technical data printed on it.
- Type of part
- Filling valves
- Status
- Refurbished
- Catalogue reference
- 2070268
- Warranty
- 1 year
Wolf boilers compatible with reference 2070268
Filling key with reference 2070268. Four confirmed compatibilities: CGB-K-20 and CGB-K-24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Wolf CGB-K-20 | Wolf | Contrasted |
| Wolf CGB-K-24 | Wolf | Contrasted |
| Wolf CGB-K-40-35 | Wolf | Contrasted |
| Wolf CGW-24/140 | Wolf | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 2070268 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 2070268. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the filling valve 2070268
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
No water enters when opening the filling valve to increase pressure.
Cause: The internal mechanism is blocked or the passage is obstructed by accumulated limescale debris.
Check that the main water shut-off valve of the house is open, as this is the most common cause.
- 02
The boiler pressure drops on its own and needs to be refilled very often.
Cause: The valve does not close completely and allows a continuous trickle of water to flow into the circuit.
Close the valve tightly, wait a few minutes, and check if the pressure gauge continues to rise without having touched it.
- 03
Is water leaking from the body or from the control of the valve?
Cause: The internal gasket has lost its tightness after many cycles of opening and closing.
Dry the area and check if the drop reappears as soon as you open the tap, to rule out that the leak is coming from a nearby connection.
- 04
It's difficult to turn, it's stuck after months of not being used.
Cause: Limescale deposits in the internal mechanism block the rotation of the control knob.
Handle it gently, without forcing it when cold; if it doesn't give, don't insist with tools.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling key Wolf 2070268
- Catalogue reference
- 2070268
- Uniclima internal SKU
- LLCWCGBK24
- Brand
- Wolf
- Type of part
- Filling valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Actual manufacturer of the component
- Caleffi
- The manufacturer printed on the part is Caleffi, not Wolf. Wolf is the boiler manufacturer; the filling valve it uses is from Caleffi.