Flow Detector Wiring Adapter Boiler CGB - Ref. 244407499
RefurbishedWolfFlow Detectors

Flow Detector Wiring Adapter Boiler CGB - Ref. 244407499

Stock · 1 unit

It detects the flow of water when a tap is opened and commands the ignition to produce domestic hot water. When it fails, no hot water comes out even though the tap is open, which can generate fault code 45: Flow sensor (flow detector) faulty. This wiring adapter is compatible with Wolf CGB-K boilers, such as models CGB-K 20, CGB-K 24, and CGB-K 40-35, among others. It should be replaced when there is a lack of hot water when the tap is opened.

VAT included

Compatibility

Wolf boilers compatible with reference 244407499

Flow meter with reference 244407499. Three confirmed compatibilities: CGB-K 20 and CGB-K 24.

Proven compatibility

Boiler modelFamilyVerification
Wolf CGB-K 20Wolf CGB-K (combi, axial flow sensor)Contrasted
Wolf CGB-K 24Wolf CGB-K (combi, axial flow sensor)Contrasted
Wolf CGB-K 40-35Wolf CGB-K (combi, axial flow sensor)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 244407499 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 244407499. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter 244407499 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The hot water comes out in spurts, it cuts off and comes back without you touching the tap.

    Cause: The flow sensor connector makes intermittent contact, and the boiler loses and regains the water flow signal.

    Move the connector with the boiler running and the water open: if the hot water cuts off or starts just by touching it, the problem is in the wiring, not in the sensor.

  • 02

    There is no domestic hot water even though the heating turns on without any problem.

    Cause: If the adapter does not transmit the signal from the sensor, the control unit does not realize that there is a demand for domestic hot water and does not switch to that mode.

    Check that the connector is properly seated and that there is no oxidation on the pins before assuming the flow sensor is faulty.

  • 03

    The water is coming out cooler than usual even though the faucet flow is normal.

    Cause: A poor contact can cause the flow reading to be distorted, and the boiler modulates the flame incorrectly.

    Check that the heat shrink tubing and cable insulation are not cracked or damp: moisture there can distort the signal.

  • 04

    The fault appears and disappears depending on how you move the pipes or wiring in that area.

    Cause: A damaged or poorly secured adapter moves with vibrations and loses contact randomly.

    Secure the wiring with cable ties and check that it does not rub against hot parts before replacing it.

Fault codes for Wolf that this part resolves.

CodeFaultDiagnosis and solution
45Flow sensor (flow detector) fault.The flow detector 244407499 does not deliver signal/pulses to the electronics (open, shorted, or without power), causing the equipment to register a sensor fault. Verify by reading the DHW flow value in the BM/BM-2 menu/thermostat while opening a tap (it does not change) and measuring continuity/power and signal from the sensor to the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Wolf 244407499 flow meter datasheet

Catalogue reference
244407499
Brand
Wolf
Type of part
Flow Detectors
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Frequently Asked Questions

Frequently asked questions about the flow meter 244407499

Is this wiring adapter compatible with a CGB 24 boiler?
Yes, it is compatible with models CGB 11, CGB 20, CGB 24, CGB K-40-35, CGB-K 20, and CGB-K 24.
What function does this adapter serve in the flow system of the CGB 20?
Connect the wiring between the flow sensor and the boiler; it is replaced when the section of connectors and original heat shrink tubing is deteriorated.

Spare parts related to Wolf Wolf CGB-K (combi, axial flow sensor)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Flow Detector Wiring Adapter Boiler CGB - Ref. 244407499