Hydraulic Body Junkers Bosch ZW20-2KE - Ref. 8707002628
Junkers Bosch ZW20-2KE is a hydraulic body (Ref. 8707002628) that is responsible for conducting and distributing water between the circuits of the boiler. When this part fails, the user may notice leaks, loss of pressure, or issues with the production of domestic hot water. It is compatible with several models from the Junkers ZW20 range, such as the ZW20KD and ZW20KE, among others. It is recommended to replace the hydraulic body when these symptoms are detected, as its poor condition can affect the performance of the boiler.
VAT included
Consult via WhatsAppJunkers boilers compatible with reference 8707002628
Hydraulic group with reference 8707002628. 30 verified compatibilities: ZW20KD23S2805 and ZW20KD23S2895.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Junkers ZW20KD23S2805 | Junkers ZW20 (KD) | Contrasted |
| Junkers ZW20KD23S2895 | Junkers ZW20 (KD) | Contrasted |
| Junkers ZW20KD31S2805 | Junkers ZW20 (KD) | Contrasted |
| Junkers ZW20KD31S2895 | Junkers ZW20 (KD) | Contrasted |
| Junkers ZW20-1KD23S2805 | Junkers ZW20 (KD) | Contrasted |
| Junkers ZW20-1KD23S2895 | Junkers ZW20 (KD) | Contrasted |
| Junkers ZW20-1KD31S2805 | Junkers ZW20 (KD) | Contrasted |
| Junkers ZW20-1KD31S2895 | Junkers ZW20 (KD) | Contrasted |
| Junkers ZW20-2KD23S2895 | Junkers ZW20 (KD) | Contrasted |
| Junkers ZW20-2KD31S2895 | Junkers ZW20 (KD) | Contrasted |
| Junkers ZW20KE | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW1KE | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20KE23S2805 | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20KE23S2895 | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20KE31S2805 | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20KE31S2895 | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20-1KE23S2805 | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20-1KE23S2895 | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20-1KE31S2805 | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20-1KE31S2895 | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20-2KE23S2895 | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20-2KE31S2895 | Junkers ZW20 (KE) | Contrasted |
| Junkers ZW20AME23S2805 | Junkers ZW20 (AME) | Contrasted |
| Junkers ZW20AME31S2805 | Junkers ZW20 (AME) | Contrasted |
| Junkers ZW20-1AME23S280 | Junkers ZW20 (AME) | Contrasted |
| Junkers ZW20-1AME31S280 | Junkers ZW20 (AME) | Contrasted |
| Junkers ZW20-2AME23S280 | Junkers ZW20 (AME) | Contrasted |
| Junkers ZW20-2AME31S280 | Junkers ZW20 (AME) | Contrasted |
| Junkers ZW201AME | Junkers ZW20 (AME) | Contrasted |
| Junkers ZW2014ME23 | Junkers ZW20 (AME) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 8707002628 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 8707002628. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the hydraulic group 8707002628 resolves.
The hydraulic group includes the valve, the by-pass, and the water connections. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The hot water comes out in bursts: sometimes it comes out nice and hot, and other times it stays lukewarm for no apparent reason.
Cause: The hydraulic body groups the water passage ducts, and if there is scale or a dried gasket inside, the flow stops being constant and the boiler modulates poorly.
Open a domestic hot water tap at maximum flow and check if the temperature remains stable for one minute; if it fluctuates, check the circuit for limescale first.
- 02
There is a puddle or drops of water under the boiler, near the area of the pipes.
Cause: The O-rings of the hydraulic body dry out over the years and allow water to pass through before it is detected by any indicator on the panel.
Dry the area well, turn on the boiler, and use a flashlight to locate if the leak is coming exactly from the hydraulic body or from a nearby fitting that can simply be tightened.
- 03
The boiler does not start producing domestic hot water even though there is demand, as if it does not detect that you open the tap.
Cause: The flow sensor is usually housed in the hydraulic body, and if the passage is partially obstructed by scale, it does not detect sufficient flow to give the ignition command.
Check the network pressure and clean the cold water inlet filter before approving this part.
- 04
You can hear a water noise or a slight whistling sound when you request domestic hot water.
Cause: A conduit narrowed by lime within the hydraulic body accelerates the flow of water at that point and generates turbulence.
Listen to see if the noise changes when you adjust the faucet flow; if it disappears at low flow, it's more indicative of limescale than a broken part.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Junkers hydraulic group 8707002628
- Catalogue reference
- 8707002628
- Brand
- Junkers
- Type of part
- Hydraulic units
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Material
- Aluminum and brass casting