Ariston Genus 27 BFFI PCB Ref. 953083
The Ariston Genus 27 BFFI PCB (Ref. 953083) is the auxiliary electronic control board of the boiler, which works in conjunction with the main board. If you experience that the boiler locks up, does not ignite, or exhibits erratic behavior, you may need to replace this board. It is compatible with the Ariston Genus 27 BFFI, Genus 23 BFFI, Genus 23 BI, Genus 27 BI models, as well as the Genus Tank 27 RI and 27 RFFI models, including the Plus, UK, and RFFI variants of the Genus 27. Consider replacing it if you notice these symptoms to ensure proper operation of your boiler.
VAT included
Consult via WhatsAppAriston boilers compatible with reference 953083
PCB with reference 953083. Six confirmed compatibilities: Genus 27 BFFI and Genus 23 BFFI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ariston Genus 27 BFFI | Ariston Genus | Contrasted |
| Ariston Genus 23 BFFI | Ariston Genus | Contrasted |
| Ariston Genus 23 BI | Ariston Genus | Contrasted |
| Ariston Genus 27 BI | Ariston Genus | Contrasted |
| Ariston Genus Tank 27 RI | Ariston Genus Tank | Contrasted |
| Ariston Genus Tank 27 RFFI | Ariston Genus Tank | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 953083 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 953083. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 953083 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite, there are no lights, it seems to be off.
Cause: a damaged PCB does not allow the system to receive power
check the fuses on the PCB and verify that there is mains power before replacing it
- 02
The display shows an error and the boiler does not start.
Cause: the PCB detects a problem in another component and stops operation as a safety measure
note the fault code and consult the manual: often the problem comes from a sensor, not from the PCB
- 03
The remote control or the panel do not respond to the changes.
Cause: the PCB does not correctly process the communication with the control unit
check the wiring or the communication bus with the control before considering that the PCB is faulty
- 04
The boiler turns on and off erratically.
Cause: Components of the PCB that are worn out (such as capacitors or solder joints) can cause intermittent faults before failing completely.
note if the fault corresponds to any specific consumption (domestic hot water or heating) to identify which circuit of the PCB is failing
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ariston PCB 953083
- Catalogue reference
- 953083
- Brand
- Ariston
- Type of part
- PCBs (control boards)
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Internal label code
- 099953083000