Ferroli PCB RPA 30 / RPA 30-2 Ref. 3T00437B
The Ferroli RPA 30 / RPA 30-2 PCB is the component that controls the ignition, burner modulation, pump, and safety features of your boiler. If it malfunctions, the boiler may not start, may lock out, or may operate erratically. This board is compatible with the Ferroli RPA 30 and RPA 30-2 models, among others. It is replaced when operational issues persist, affecting the boiler's performance.
VAT included
Consult via WhatsAppCompatible Ferroli boilers
PCB. Two confirmed compatibilities: RPA 30 and RPA 30-2.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli RPA 30 | Ferroli | Contrasted |
| Ferroli RPA 30-2 | Ferroli | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB (control board) resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler shows no signs: no lights, no display, as if it has no power.
Cause: The PCB is not supplying voltage to the installation because the main relay is not closing or it is not receiving power.
Measure with the multimeter that 230V is entering the PCB before declaring it dead; sometimes the problem comes from outside.
- 02
A fault code appears on the display and the boiler stops.
Cause: The electronics cut the cycle upon detecting an anomaly, although the source may be in a sensor that reports to the PCB and not in the PCB itself.
Note the exact code and consult the manual of the RPA 30 before changing the PCB, it may point to another component.
- 03
You request heat from the thermostat and the boiler does not respond.
Cause: The PCB is not reading or processing the demand signal coming from outside.
Bridge the demand terminals directly on the PCB to see if it starts without the thermostat in between.
- 04
The boiler turns on and off by itself intermittently, without a fixed pattern.
Cause: A loose solder joint or a worn relay in the circuit causes intermittent power cuts.
With the boiler on, gently touch the PCB to see if the cut matches the rubbing; it is a sign of cold soldering.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Ferroli PCB data sheet
- Brand
- Ferroli
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Code printed on the circuit
- 3T00437B
- Main line voltage (relay)
- 230V~ 50-60Hz
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ferroli RPA 30-2 Manual (PDF)Document © Ferroli, provided as a technical reference.