LED Display PCB for NEW ELITE C24E, C30E, F24, F24E, F30, and F30E
The LED Display PCB for NEW ELITE C24E, C30E, F24, F24E, F30, and F30E is the component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, lock out, or exhibit erratic behavior. It is installed in several models of the New Elite range, including the F24E. Replacement is necessary when you experience these operational issues.
VAT included
Consult via WhatsAppFerroli boilers compatible with reference I39809641
PCB with reference I39809641. A proven compatibility: F24E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli F24E | New Elite | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. I39809641 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference I39809641. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB I39809641 resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The screen does not show anything, not even an LED lit.
Cause: The display board is not receiving power or the LED circuit is damaged.
Check that the 16-pin flat ribbon connector is properly seated at both ends and that there are no bent pins.
- 02
The LEDs flicker erratically or turn on and off by themselves.
Cause: A poor connection in the flat ribbon cable causes the signal between the main PCB and the display PCB to arrive intermittently.
Disconnect and reconnect the flat ribbon cable, making sure it is not bent, pinched, or corroded at the terminals.
- 03
The boiler is functioning normally, but there is no information displayed on the screen.
Cause: The fault is in the display PCB or its connection, not in the boiler's main control.
Check if pressing the buttons on the remote shows internal changes (relays, burner) even if the screen does not reflect it; if so, the problem is with the LED board, not the main one.
Fault codes for Ferroli that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F50 | Anomaly in the control board. | A problem has been detected in the boiler's control board, which may affect its overall operation. If the boiler does not respond correctly to commands or shows faults, the issue may be with the PCB. Check the connections and the condition of the board. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ferroli PCB I39809641
- Catalogue reference
- I39809641
- Brand
- Ferroli
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Connector
- 16-pin flat ribbon cable, designator X1
- LED indicators
- Row of 6 green LEDs (L1-L6)
- Additional LED