Junkers Cerastar ZWE 24-3 PCB Ref. 8748300267

Junkers Cerastar ZWE 24-3 PCB Ref. 8748300267

If your boiler does not start, locks out, or exhibits erratic behavior, a technical diagnosis must confirm whether you need the Junkers Cerastar ZWE 24-3 PCB, reference 8748300267. This control board manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, you may notice that the boiler does not operate as it should. It is compatible with several models from the Junkers Eurostar and Cerastar ranges, such as the ZWE 24-3 MFK and the ZE 24-3 MFA, among others. A technician must confirm through diagnosis whether it needs to be replaced upon detecting these malfunction symptoms.

Catalogue reference
87483002670
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Junkers boilers compatible with reference 87483002670

PCB with reference 87483002670. Ten verified compatibilities: ZWE 24-3 MFK and ZWE 24-3 MFKD.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWE 24-3 MFKJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZWE 24-3 MFKDJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZWE 24-3 MFADJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZWE 24-3 MFAJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZWE 24-3 HADJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZWE 24-3 HKDJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZE 24-3 MFKJunkers Eurostar / Cerastar ZE 24-3Contrasted
Junkers ZE 24-3 MFAJunkers Eurostar / Cerastar ZE 24-3Contrasted
Junkers ZWE 28-3 MFADJunkers Eurostar / Cerastar ZWE 28-3Contrasted
Junkers ZWE 28-3 HADJunkers Eurostar / Cerastar ZWE 28-3Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87483002670 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87483002670. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 87483002670

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start at all: no display, no fan, and no noise when powered on.

    Cause: If the power supply stage of the PCB fails, the entire boiler remains uncontrolled even if it receives mains power.

    Check the fuse on the PCB and make sure that the main switch and the differential switch in the house have not tripped.

  • 02

    The same fault code keeps appearing even though the component it indicates seems to be in good condition.

    Cause: The PCB interprets that signal, and if the fault is in its reading circuit, the fault code appears even if the sensor is in good condition.

    Measure the component indicated by the code with a multimeter before declaring the PCB responsible.

  • 03

    The three-way valve gets stuck prioritizing domestic hot water or heating, unable to alternate.

    Cause: The PCB controls the motor of the three-way valve, and a fault in that output leaves it stuck in a single position.

    Check that the valve turns freely by hand before assuming that the fault is with the PCB that controls it.

  • 04

    The remote control loses connection: it does not display the temperature or allow any adjustments.

    Cause: Communication with the control is managed from the PCB, and a fault at that stage cuts off the signal even if the control is in good condition.

    Check the communication bus wiring on the terminal block of the PCB before replacing it.

Junkers fault codes that require diagnosis

CodeFaultTechnical checks
E0Internal fault in the PCB.The self-diagnosis detects an internal fault in the main board; the manufacturer prescribes replacing the printed circuit board. Beforehand, check power supplies/connections and fuses and reset: if the E0 reappears, the PCB is defective.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers 87483002670 PCB.

Catalogue reference
87483002670
Uniclima internal SKU
PLBO170
Brand
Junkers
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Silkscreened code on the PCB
8 748 300 267
Relay marking
GZT 3 / AB AA AA
Frequently Asked Questions

Frequently asked questions about the PCB 87483002670

Does this PCB work for my Cerastar ZWE 24-3 MFA boiler?
Yes, it is among the models with confirmed compatibility, along with the versions ZE 24-3, ZWE 24-3 (HA, HK, MFK) and ZWE 28-3 (HA, MFA).
What is the brand "GZT 3" that appears on the orange relay of this PCB?
It is the marking of the relay mounted on the PCB, not the identification code of the complete board.

Spare parts related to Junkers Junkers Eurostar / Cerastar ZWE 24-3

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Junkers Cerastar ZWE 24-3 PCB Ref. 8748300267