Junkers Eurostar ZWE24-3 / ZE24-3 PCB - Code 6 748 200

Junkers Eurostar ZWE24-3 / ZE24-3 PCB - Code 6 748 200

Stock · 1 unit

When you turn on the hot water tap or activate the heating, the Junkers Eurostar ZWE24-3 / ZE24-3 PCB (control board) - Code 6 748 200 is responsible for controlling the ignition, the modulation of the burner, and the boiler pump. If this part fails, you will notice that the boiler does not start, gets locked, or behaves erratically, showing the fault code E0: internal fault in the PCB. It is compatible with models such as the ZWE 24-3 MFK and ZE 24-3 MFK, among others. It should be replaced when these faults or abnormal behaviors occur.

VAT included

Compatibility

Junkers boilers compatible with reference 87483002670

PCB with reference 87483002670. Ten verified compatibilities: ZWE 24-3 MFK and ZWE 24-3 MFKD.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZWE 24-3 MFKJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZWE 24-3 MFKDJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZWE 24-3 MFADJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZWE 24-3 MFAJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZWE 24-3 HADJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZWE 24-3 HKDJunkers Eurostar / Cerastar ZWE 24-3Contrasted
Junkers ZE 24-3 MFKJunkers Eurostar / Cerastar ZE 24-3Contrasted
Junkers ZE 24-3 MFAJunkers Eurostar / Cerastar ZE 24-3Contrasted
Junkers ZWE 28-3 MFADJunkers Eurostar / Cerastar ZWE 28-3Contrasted
Junkers ZWE 28-3 HADJunkers Eurostar / Cerastar ZWE 28-3Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87483002670 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87483002670. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 87483002670 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is off and does not respond when pressing anything on the panel.

    Cause: The PCB controls the power supply and operation of the boiler; if it fails, the unit does not respond.

    Check that there is power at the input of the PCB and inspect the condition of the fuse before purchasing it.

  • 02

    An error code appears on the screen that reappears after resetting several times.

    Cause: The control circuit detects a fault in a sensor or component and locks the equipment for safety.

    Note the exact code: some may correspond to external sensors and not to the PCB itself.

  • 03

    The flame ignites strongly and then flickers or goes out, without stabilizing.

    Cause: A fault in the gas valve control circuit prevents the PCB from maintaining stable modulation.

    First, rule out a gas pressure issue or a gas valve problem, as the symptom is similar.

  • 04

    The boiler control does not respond even when the buttons or the thermostat are manipulated.

    Cause: The PCB may have lost the reading of the control inputs and is not executing the commands.

    Check the connectors of the remote control and the thermostat before replacing the PCB.

  • 05

    The boiler works well some days and does not start on others, without a clear pattern.

    Cause: Intermittent faults on the PCB are usually due to solder joints or components that fail depending on the temperature.

    Note under what conditions it fails (cold, humidity, time on) to identify if the problem is with the PCB.

Fault codes from Junkers that this part resolves.

CodeFaultDiagnosis and solution
E0Internal fault in the PCB.The self-diagnosis detects an internal fault in the main board; the manufacturer prescribes replacing the printed circuit board. Beforehand, check power supplies/connections and fuses and reset: if the E0 reappears, the PCB is defective.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers 87483002670 PCB.

Catalogue reference
87483002670
Brand
Junkers
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Silkscreened code on the PCB
6 748 200
Central DIP chip code
B 748 300 233
Frequently Asked Questions

Frequently asked questions about the PCB 87483002670

For which versions of the Junkers Eurostar is this PCB compatible?
It is listed for ZE24-3 and ZWE24-3/ZWE28-3, in its versions MFKD23, MFKD31, HAD23, MFAD23, and MFK.
What code will be silk-screened on the PCB of the Junkers Eurostar ZE24-3, apart from the central chip?
The code 6 748 200, printed on the PCB itself.

Spare parts related to Junkers Junkers Eurostar / Cerastar ZWE 24-3

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model