Junkers Novatherm ZW20 KD / KD23 PCB - Ref. 8 748 300 246

Junkers Novatherm ZW20 KD / KD23 PCB - Ref. 8 748 300 246

When you open the hot water tap or turn on the heating, the Junkers Novatherm ZW20 KD / KD23 PCB (control board) - Ref. 8 748 300 246 is responsible for controlling the ignition and modulation of the burner, as well as the pump and safety features of the boiler. If this part fails, you will notice that the boiler does not start, locks out, or behaves erratically, possibly displaying the fault codes E0 or F0. It is compatible with models such as the ZW20-1AME23 and ZW20-2AME, among others in the Junkers Novastar ZW20 range. A technician must confirm through diagnosis whether it needs to be replaced when it shows operational faults.

Catalogue reference
87483002460
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Junkers boilers compatible with reference 87483002460

PCB with reference 87483002460. Five confirmed compatibilities: ZW20-1AME23 and ZW20-1AME23 S2805.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZW20-1AME23Junkers Novastar ZW20 (atmospheric)Contrasted
Junkers ZW20-1AME23 S2805Junkers Novastar ZW20 (atmospheric)Contrasted
Junkers ZW20-1AMEJunkers Novatherm/Novastar ZW20 (family)Contrasted
Junkers ZW20-2AMEJunkers Novatherm/Novastar ZW20 (family)Contrasted
Junkers ZW20-AMEJunkers Novatherm/Novastar ZW20 (family)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 87483002460 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87483002460. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 87483002460

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start or give any signal when the switch is pressed.

    Cause: The PCB is not sending power to the circuits that should initiate the ignition.

    Check that power is reaching the boiler's input and inspect the fuse on the PCB before replacing it.

  • 02

    Different fault codes appear each time, unrelated to any component you have already checked.

    Cause: It's a typical symptom of a damaged PCB: the control electronics provide erratic diagnostics because the fault is within itself.

    Note each fault code that appears during a day of use; if the same one doesn't repeat, the PCB is more suspect than a specific sensor.

  • 03

    Neither the remote control nor the thermostat can start the boiler, although it does turn on in manual mode.

    Cause: The part of the PCB that receives the heat demand order from the outside is failing.

    Do not force, hit, or bridge the component. Request a technical check according to the equipment manual before deciding on its replacement.

  • 04

    The pump or the gas valve do not activate even though the ignition sequence seems to start normally.

    Cause: The relay on the PCB that controls that output may have burned out or become stuck.

    Measure with the multimeter if there is power at the connector of the pump or the valve when the boiler requests ignition.

Junkers fault codes that require diagnosis

CodeFaultTechnical checks
E0Internal fault in the PCB.Self-diagnosis detects a fault in the PCB (control board). Check power supply and connections; if it persists after reset, replace the PCB.
F0Internal fault.Internal fault of the control module; the PCB does not initialize or fails during startup. Check ignition contacts and cables; if it persists, replace the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers 87483002460 PCB.

Catalogue reference
87483002460
Uniclima internal SKU
PLCJNOVZW20
Brand
Junkers
Type of part
PCBs (control boards)
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Junkers
PCB code
8 748 300 246
Before purchasing
  • The current trade name sells it as 'Novatherm', but the wordmark printed on the plate is 'JUNKERS'; both names correspond to the same range of boilers, it is not a contradiction of technical data.
Frequently Asked Questions

Frequently asked questions about the PCB 87483002460

Who manufactures the PCB for the Junkers Novatherm ZW20 KD23?
Junkers; the wordmark is clearly printed on the screen printing.
What code is printed on the PCB of the Novatherm ZW20 KD?
8 748 300 246, reconstructed by comparing several photographs of the same piece because in some shots the final characters appeared cut off.
Is this PCB suitable for the Junkers Novatherm ZW20-1KD?
Yes, it is listed as compatible along with ZW20 KD and ZW20 KD23.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Junkers Novatherm ZW20 KD / KD23 PCB - Ref. 8 748 300 246