Junkers PCB ZWE24-2KDG Ref. 8748300214

Junkers PCB ZWE24-2KDG Ref. 8748300214

Stock · 1 unit

In the Junkers ZWE24-2KDG boilers, the PCB acts as the brain of the system, controlling the ignition, burner modulation, pump, and safety features. When this component fails, the boiler may not start, become locked, or exhibit erratic operation. Users may experience faults such as E0, which indicates a fault in the PCB, or F0, which signals an internal fault. This PCB is compatible with models from the Eurostar range, such as the ZWE 24-2 KDP and other similar ones. It is recommended to replace it when the mentioned symptoms are present.

VAT included

Compatibility

Junkers boilers compatible with reference 8748300213

PCB with reference 8748300213. Four confirmed compatibilities: ZE 24-2 KDP and ZWE 24-2 KDP.

Proven compatibility

Boiler modelFamilyVerification
Junkers ZE 24-2 KDPEurostar (ZWE 24 atmospheric, KD/KP generation)Contrasted
Junkers ZWE 24-2 KDPEurostar (ZWE 24 atmospheric, KD/KP generation)Contrasted
Junkers ZWE 24-2 KDGEurostar (ZWE 24 atmospheric, KD/KP generation)Contrasted
Junkers ZWE 24-2 KP (24KP)Eurostar (ZWE 24 atmospheric, KD/KP generation)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 8748300213 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 8748300213. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 8748300213 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    When the power-on command is given, nothing happens: neither the fan is heard nor anything appears on the display.

    Cause: The PCB does not send current to the start stage, usually due to a blown fuse or an internal fault.

    First, check the fuse on the PCB; it is usually visible on the edge of the board, before replacing the entire component.

  • 02

    The display shows a fault code, but when turning the boiler off and on again, it works for a while as if nothing happened.

    Cause: It is typical for a PCB with an intermittent fault to be temporarily corrected by resetting.

    Record how many times the same fault code occurs in a day; if it is recurrent with the boiler cold and running, it is not a coincidence.

  • 03

    You have changed the setting on the room thermostat and the boiler does not respond, as if it doesn't hear it.

    Cause: The PCB does not manage the communication with the modulating regulator or thermostat properly.

    Check that the wiring of the control reaches the corresponding terminals of the PCB and that there is no moisture or oxidation in the connector.

  • 04

    You notice a slight burnt smell or see a blackened spot on some component of the PCB, even though the boiler still starts up.

    Cause: It is usually a relay or a capacitor on the PCB that has degraded and will eventually fail completely.

    With the boiler unplugged, visually inspect the PCB for dark spots, odor, or swollen components before deciding on the replacement.

Fault codes from Junkers that this part resolves.

CodeFaultDiagnosis and solution
E0Fault in the control board/PCB (internal fault in the control electronics).The PCB does not pass the self-diagnosis (internal hardware/power or communication fault); check mains voltage, fuses, and connectors, and measure 5/12 V voltages on the board; if it persists after reset, the board is defective.
F0Internal fault (control unit/PCB error).Internal fault of the PCB (hardware/memory or moisture on the board) causing a lockout; check that the board is not damp or damaged, inspect connections and supply voltages; if not resolved, replace or repair the board.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Junkers 8748300213 PCB.

Catalogue reference
8748300213
Brand
Junkers
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Fuse
0.4A
Printed code (this unit)
8 748 300 214
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 8748300213

Is the PCB of the Junkers ZWE24-2KDG original from the brand?
The manufacturer listed is Junkers, part of the Bosch Thermotechnology group, with the JUNKERS logo printed on the circuit itself.
What fuse does the PCB of the ZWE24-2KDG use?
A 0.4 A fuse, according to the circuit silkscreen.
Does this PCB work for a ZE24-2KP boiler?
Yes, the ZE24-2KP is among the compatible models, along with ZE24-2KDP, ZWE24-2KDG, ZWE24-2KDP, and ZWE24-2KP.
How do I know if my ZWE24-2KDP needs this same PCB or a different reference?
Checking the complete code printed on your current PCB: different codes have been read for this product according to the photo (8748300214, 8748200214, and 8748300213).

Spare parts related to Junkers Eurostar (ZWE 24 atmospheric, generation KD/KP)

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Junkers PCB ZWE24-2KDG Ref. 8748300214