PCB Celtic 1.30 / Celtic 2.20 / Celtic RSCB / GM-15-20 Ref. 79932-N

PCB Celtic 1.30 / Celtic 2.20 / Celtic RSCB / GM-15-20 Ref. 79932-N

When you turn on the tap or activate the heating, the PCB Celtic 1.30 / Celtic 2.20 / Celtic RSCB / GM-15-20 Ref. 79932-N is responsible for controlling the ignition, the modulation of the burner, and the operation of the pump in your boiler. If this part fails, you will notice that the boiler does not start, gets locked, or exhibits erratic behavior, potentially showing faults such as 3 02, 3 03, or 3 05. It is compatible with models such as Celtic 18/23 RSCE, Celtic 2.20 RSc b, and GM 2-20 RSc b, among others. A technician must confirm through diagnosis whether replacement is necessary when you observe these symptoms or faults in the system.

Catalogue reference
60079932
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Chaffoteaux boilers compatible with reference 60079932

PCB with reference 60079932. Four confirmed compatibilities: Celtic 18/23 RSCE and Celtic 2.20 RSc b.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux Celtic 18/23 RSCEChaffoteaux Celtic RSc b / RSCE (18-23 kW)Contrasted
Chaffoteaux Celtic 2.20 RSc bChaffoteaux Celtic RSc b / RSCE (18-23 kW)Contrasted
Chaffoteaux Celtic 2.24 RSc bChaffoteaux Celtic RSc b / RSCE (18-23 kW)Contrasted
Chaffoteaux GM 2-20 RSc bChaffoteaux GM RSc bContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number 60079932 is the one for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 60079932. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB 60079932

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and when opening the PCB, the fuse is blown.

    Cause: The fuse protects the control circuit; if it blows, it cuts off the power to the PCB even if the rest of the boiler is in good condition.

    Before replacing the PCB, just replace the 7A 24V fuse and check if it blows again immediately; that indicates a short circuit at another point in the circuit.

  • 02

    The room thermostat is calling for heat, but the boiler does not start.

    Cause: The thermostat demand enters the PCB through terminal TA; if that circuit fails, the ignition command does not reach even if the thermostat is functioning properly.

    Do not bridge contacts or power components directly to test them. Request a technician to check the cause according to the model manual and its revision, without bypassing the protections. The symptom or fault code does not confirm on its own that this part is faulty.

  • 03

    The boiler works with the manual switch but does not respond to any external control.

    Cause: When the PCB receives power but does not process the input signals correctly, the unit may start forcibly but does not respond to the automatic control.

    Check the wires that connect to terminal TA and their connections before considering the PCB as the cause of the fault.

Chaffoteaux fault codes that require diagnosis

CodeFaultTechnical checks
3 02Communication error between the internal electronics (PCB) and other modules/HMI.The main PCB may fail in its communication bus or not supply the correct voltage/ground to the display; check HMI↔PCB wiring, regulated 5 V, and continuity. If everything is correct, the PCB is damaged.
3 03Main PCB fault.Self-diagnosis detects an internal fault in the PCB (micro/EEPROM, relays, power supply); confirm voltages 230 V/24 V/5 V, fuses, and tracks. If after reset and verifications it persists, replace the PCB.
3 05Main PCB fault.Internal fault of the PCB (shorts/moisture/faulty components); check supply and regulations on the board and signs of damage. If the error reappears, the repair involves replacing the PCB.
3 06Main PCB fault.Internal fault of the control electronics; confirm stable 5 V/12 V, relays, and solder joints. If there are no external anomalies, the cause is the PCB itself.
3 07Main PCB fault.Critical anomaly detected in the PCB (e.g., microcontroller or supervision failure); if it persists after reset and verification of voltages/cabling, proceed to replace the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Chaffoteaux 60079932 PCB.

Catalogue reference
60079932
Uniclima internal SKU
PEC1823RSCE
Brand
Chaffoteaux
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Code printed on PCB
79932-N
Secondary code/batch
100A 94 46
Fuse
7A 24V
Label terminal ambient thermostat
TA 24V
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the PCB 60079932

What code is printed on the PCB of the Celtic 1.30?
79932-N, with batch 100A 94 46 printed next to the code.
Does this PCB work for the GM-15-20 in addition to the Celtic range?
Yes, it is compatible with GM-15-20 and with Celtic 1.30, 2.20 and RSCB.
What fuse does the PCB of the Celtic 2.20 use?
A 7A 24V fuse, next to the fuse holder, with a TA 24V terminal for the room thermostat.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model