PCB Control Boiler CE24E

PCB Control Boiler CE24E

Stock · 2 units

When you open the hot water tap or turn on the heating, the CE24E Control PCB from Fagor manages the ignition, burner modulation, pump, and safety features of the boiler. If this part fails, you will notice that the boiler does not start, gets locked, or exhibits erratic operation. The associated fault codes are F5, which indicates an internal fault in the electronic circuit, and F10, which signals a failure in the control or closure of the gas valve. This PCB is compatible with models such as the FE 27 E, among others. It is recommended to replace it when you experience these symptoms of malfunction.

VAT included

Compatibility

Fagor boilers compatible with reference N03G010M3

PCB with reference N03G010M3. A proven compatibility: FE 27 E.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE 27 EFagor SupercompactContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part N03G010M3 is the one for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference N03G010M3. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB N03G010M3 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and there is no electrical signal on the panel.

    Cause: The transformer on the PCB is not sending current to the rest of the circuit; without that output, there is no activity.

    Measure with a multimeter if the transformer on the PCB is providing output voltage before declaring the board faulty.

  • 02

    It lights up for a moment and then turns off immediately, repeating the attempt several times.

    Cause: The microcontroller on the PCB does not manage the ignition correctly; a fault there can abort the process as soon as it starts.

    Count how many seconds it always takes to turn off: a fixed and repeated time points to the PCB before an external sensor.

  • 03

    The boiler does not respond to the temperature changes set on the panel.

    Cause: The PCB does not correctly interpret the command from the control panel; if the microcontroller fails, the command does not reach the burner.

    Try another temperature value and see if the flame intensity changes before blaming the PCB.

  • 04

    The clicking sound of a relay from the PCB is heard, but the corresponding component does not activate.

    Cause: A relay can close mechanically but not provide current if its contacts are worn or oxidized internally.

    Check with the multimeter for continuity and output current in that relay before replacing the entire PCB.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F5Control board fault: internal fault in the electronic circuit causing the boiler to lockout.It is the code that the brand itself directly attributes to an internal fault of the main PCB (this part); it is verified by ruling out power supply and connections, and checking that the lock persists after a reset, in which case the PCB is the cause.
F10Fault in the control or closure of the gas valve (cannot be unlocked).The brand documents this fault as related to the control circuit of the O valve itself; when the gas valve is healthy, the origin is the control circuit governed by the PCB (this part). It is verified by measuring the signal/coil of the valve: if the valve responds correctly and the F10 persists, the cause is the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Fagor N03G010M3 PCB.

Catalogue reference
N03G010M3
Brand
Fagor
Type of part
PCBs (control boards)
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Transformer - primary voltage
230V~
Transformer - primary current (fuse T)
80mA/T
Transformer - power
12VA
Transformer - secondary voltage/current
14V / 0.65A
Transformer - regulations
EN 61558, EI 54/19
Transformer - model code
1122883C
Microcontroller - marking
CONTROL 103 1130 / MU0870780 / 13/05
Frequently Asked Questions

Frequently asked questions about the PCB N03G010M3

What technical data can be read on this PCB of the CE24E boiler?
The transformer (230V~ primary, output 14V/0.65A, 12VA) and the marking of the microcontroller 'CONTROL 103 1130'.
Does this PCB Ref. N03G010M3 work for my boiler CE24E?
Yes, it is compatible with the CE24E model.

Spare parts related to Fagor Fagor Supercompact

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
PCB Control Boiler CE24E