PCB Gruppo Giordano Boiler Fagor Natur 24281N / 28301N
When you turn on the tap or start the heating, the Gruppo Giordano PCB for Fagor boiler Natur 24281N / 28301N is responsible for controlling the ignition, the modulation of the burner, and the pump. If this part fails, you will notice that the boiler does not start, gets locked, or operates erratically. It is compatible with the Natur 24281N and 28301N models, among others. Replacement is recommended when you experience these symptoms, as it is crucial for the operation of the boiler.
VAT included
Consult via WhatsAppCompatible Fagor boilers
PCB. Two confirmed compatibilities: 24281N and 28301N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor 24281N | NATUR | Contrasted |
| Fagor 28301N | NATUR | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB (control board) resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not respond to any commands: neither the thermostat, nor the panel, nor anything.
Cause: The control circuit of the PCB centralizes all the ignition commands; if it fails, no pathway can start the boiler.
Check that the boiler has real electrical supply and that the internal fuse of the PCB is not blown before replacing it.
- 02
The fan does not start, and the boiler locks out due to a flue fault without any blockage in the duct.
Cause: The PCB sends the electrical signal to the fan; if the relay or the corresponding output fails, the fan does not receive power even if it is functioning properly.
With the fan disconnected, measure if there is voltage coming from the PCB at the moment it should start.
- 03
The indicators or the display are flashing abnormally without showing a clear fault code.
Cause: A fault in the control circuit of the PCB can alter the signal that reaches the display without generating a defined error.
Disconnect and reconnect the display connector to the PCB to rule out a loose connection before replacing it.
- 04
The boiler starts up well when cold but fails after being hot for a while.
Cause: Some components of the PCB lose reliability with operating heat and fail only when they are at working temperature.
Check if the fault occurs consistently after a similar operating time: this points to a heat-sensitive component on the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Fiche of the Fagor PCB.
- Brand
- Fagor
- Type of part
- PCBs (control boards)
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- manufacturer of the component
- Gruppo Giordano