Fagor PCB Ref. N03G009M8

Fagor PCB Ref. N03G009M8

Stock · 3 units

The Fagor PCB Ref. N03G009M8 is used in Fagor boilers, such as the CE24EN and FE24EN, among others. Its main function is to control the ignition, burner modulation, pump, and safety features of the boiler. When this part fails, the boiler may not start, become locked, or operate erratically, which can generate faults F5 and F10. This board is compatible with models from the FE24E, CA24E, and FA23E ranges. It is recommended to replace it when it shows obvious faults or errors in operation.

VAT included

Compatibility

Fagor boilers compatible with reference N03G009M8

PCB with reference N03G009M8. 12 verified compatibilities: FE-24E/1 N and FE-24E/1 B.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE-24E/1 NFE24EContrasted
Fagor FE-24E/1 BFE24EContrasted
Fagor FE-24E H/1 NFE24EContrasted
Fagor FE24EC/1 BFE24EContrasted
Fagor FE24EC/1 NFE24EContrasted
Fagor CA24E BCA24EContrasted
Fagor CA24E NCA24EContrasted
Fagor FA23E BFA23EContrasted
Fagor FA23E NFA23EContrasted
Fagor FE27E/1 BFE27EContrasted
Fagor FE27E/1 NFE27EContrasted
Fagor FE27ECN/1 NFE27EContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. N03G009M8 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference N03G009M8. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB N03G009M8 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and the ignition pilot light does not turn on.

    Cause: If the PCB does not supply power correctly, neither the ignition indicator nor the unit starts.

    Measure that the boiler receives 230V at the input and check that the differential has not tripped before replacing the PCB.

  • 02

    A different fault code appears each time the boiler is reset.

    Cause: Damaged components on the PCB can cause incorrect readings that change with each startup.

    Note the codes that appear: if none are repeated, it is more likely to be a fault with the PCB than with a specific sensor.

  • 03

    The domestic hot water does not start even though the heating circuit is working fine.

    Cause: The PCB manages the domestic hot water circuit separately; a fault in that output only affects that function.

    Make sure that the domestic hot water tap opens enough flow to activate the flow detector before blaming the PCB.

  • 04

    The boiler stops by itself after a period of normal operation.

    Cause: A relay or a faulty solder joint on the PCB can interrupt the supply without any apparent external cause.

    Observe if the cut always occurs after a similar time: this suggests a problem with the PCB rather than an external fault.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F5Control board fault: internal fault in the electronic circuit causing the boiler to lockout.It is the code that the FE-24E range displays when the PCB fails internally. Check after ruling out correct power supply and connections: if the F5 persists with correct wiring and sensors, the PCB (N03G009M8) is the cause and should be replaced.
F10Fault in the control or closure of the gas valve; cannot be unlocked.Sources document that the origin may be the control circuit (the PCB) OR the gas valve itself. Verify by measuring the signal/power supply that the PCB sends to the valve: if the PCB does not correctly control the valve (signal absent or incorrect with a healthy valve), the PCB N03G009M8 is the cause. Shared cause, not exclusive to the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Fagor N03G009M8 PCB.

Catalogue reference
N03G009M8
Brand
Fagor
Type of part
PCBs (control boards)
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

PCB reference (Fagor)
N03G009M8 - applies to Fagor CE24EN / FE24EN
Transformer - Reading 1
Aviser 230V, 60mA T, EI54/19, 12VA, 40C/B, 50/60Hz
Transformer - reading 2
Aviser 230V, 80mA T, EI54/19, 12VA, 40C/B, 50/60Hz, secondary 4V/0.85A
Transformer - reading 3
Aviser 230V, 60mA T, EI30/10ST, Sec.150V~1mA
Auxiliary relay - reading 1
Aviant 230V, T8R/9-26/60Hz, Sec.150V~1mA
Auxiliary relay - reading 2
Aviant 230V, T8R/8-55/60Hz, Sec.150V~1mA
EGO relay block code
CONTROL 204A N05G009M8
Frequently Asked Questions

Frequently asked questions about the PCB N03G009M8

Is the PCB N03G009M8 compatible with the boiler Fagor FE-24E/1 N?
Yes, the PCB N03G009M8 is compatible with the boiler Fagor FE-24E/1 N, as it is included in the list of confirmed models.
Does the PCB N03G009M8 work for the CA24E range?
Yes, the PCB N03G009M8 is compatible with the models in the CA24E range, which include CA24E B and CA24E N.
What fault codes are documented for the PCB N03G009M8?
The documented fault codes for the PCB N03G009M8 are F5 and F10.
How many models are compatible with the PCB N03G009M8?
The PCB N03G009M8 is compatible with a total of 12 models of Fagor boilers.
Is the reference PLCF24ENX related to the PCB N03G009M8?
Yes, the reference PLCF24ENX is related to the PCB N03G009M8, which is the part you need.

Spare parts related to Fagor FE24E

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Fagor PCB Ref. N03G009M8