Fagor MF-12 N PCB Honeywell Ref. MU0104200
Control PCB for Fagor MF-12 C, MF-12 GLP, and MF-12 N boilers. The component identified on the label is a Honeywell module with code W4115B-1317, powered at 230V 50Hz and protected with a 2A delayed fuse (2AT). Replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler does not ignite, does not respond to controls, or the electronic component stops functioning.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- Catalogue reference
- MU0104200
- Warranty
- 1 year
Fagor boilers compatible with reference MU0104200
PCB with reference MU0104200. Three confirmed compatibilities: C and LPG.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor C | MF-12 | Contrasted |
| Fagor GLP | MF-12 | Contrasted |
| Fagor N | MF-12 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number MU0104200 is the one for your boiler.
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference MU0104200. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the PCB MU0104200
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and the display remains off.
Cause: The internal power supply of the PCB does not power the control circuits.
Measure the fuse with a multimeter and the mains voltage before replacing the PCB.
- 02
The remote control or the room thermostat does not do anything.
Cause: The PCB does not process or receive the signal from the remote control.
Force the built-in thermostat of the boiler to rule out an external wiring issue before blaming the PCB.
- 03
The screen and the indicators suddenly turn off for no apparent reason.
Cause: Internal power cut on the PCB, typical of a blown fuse or a power supply failure.
Measure if 230V is reaching the input of the PCB before considering it faulty.
- 04
The boiler ignites sometimes and sometimes it doesn't, without a clear pattern.
Cause: A degraded component or a loose solder joint on the PCB causes intermittent behavior.
Note under what conditions it fails (cold, hot, after how much time) to confirm that the pattern points to the PCB.
Fagor fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F5 | PCB fault (internal fault of the electronic circuit). | This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor MU0104200 PCB.
- Catalogue reference
- MU0104200
- Uniclima internal SKU
- PEFMF12N
- Brand
- Fagor
- Type of part
- PCBs (control boards)
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Component manufacturer
- Honeywell
- PCB code
- W4115B-1317
- Power supply
- 230V 50Hz
- Fuse
- 2AT (2A delayed)