Fagor MF-12 N PCB Honeywell Ref. MU0104200

Fagor MF-12 N PCB Honeywell Ref. MU0104200

Stock · 6 units

Control PCB for Fagor MF-12 C, MF-12 GLP, and MF-12 N boilers. The component identified on the label is a Honeywell module with code W4115B-1317, powered at 230V 50Hz and protected with a 2A delayed fuse (2AT). It is replaced when the boiler does not ignite, does not respond to controls, or the electronic part stops functioning.

VAT included

Compatibility

Fagor boilers compatible with reference MU0104200

PCB with reference MU0104200. Three confirmed compatibilities: C and LPG.

Proven compatibility

Boiler modelFamilyVerification
Fagor CMF-12Contrasted
Fagor GLPMF-12Contrasted
Fagor NMF-12Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number MU0104200 is the one for your boiler.

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MU0104200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB MU0104200 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and the display remains off.

    Cause: The internal power supply of the PCB does not power the control circuits.

    Measure the fuse with a multimeter and the mains voltage before replacing the PCB.

  • 02

    The remote control or the room thermostat does not do anything.

    Cause: The PCB does not process or receive the signal from the remote control.

    Force the built-in thermostat of the boiler to rule out an external wiring issue before blaming the PCB.

  • 03

    The screen and the indicators suddenly turn off for no apparent reason.

    Cause: Internal power cut on the PCB, typical of a blown fuse or a power supply failure.

    Measure if 230V is reaching the input of the PCB before considering it faulty.

  • 04

    The boiler ignites sometimes and sometimes it doesn't, without a clear pattern.

    Cause: A degraded component or a loose solder joint on the PCB causes intermittent behavior.

    Note under what conditions it fails (cold, hot, after how much time) to confirm that the pattern points to the PCB.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F5PCB fault (internal fault of the electronic circuit).The control PCB fails due to damage in components/power supplies or software protection; the boiler locks out. Check by measuring voltages 230V→low on the PCB, connectors, and relays, and ideally with a cross-test by temporarily replacing the board MU0104200.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Fagor MU0104200 PCB.

Catalogue reference
MU0104200
Brand
Fagor
Type of part
PCBs (control boards)
Units in stock
6 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component manufacturer
Honeywell
PCB code
W4115B-1317
Power supply
230V 50Hz
Fuse
2AT (2A delayed)
Frequently Asked Questions

Frequently asked questions about the PCB MU0104200

Which manufacturer has the MU0104200 PCB of the Fagor MF-12 N?
Honeywell; the logo is clearly printed on the PCB.
Does this PCB MU0104200 work for the Fagor MF-12 GLP?
Yes, it is compatible with MF-12 C, MF-12 GLP, and MF-12 N.
What fuse does the Honeywell W4115B-1317 PCB use?
A 2A delayed fuse (2AT).
What voltage does the MU0104200 PCB of the Fagor MF-12 N operate at?
A 230V 50Hz.
When should the PCB of the Fagor MF-12 N be replaced?
It is replaced when the boiler does not ignite, does not respond to the controls, or the PCB stops functioning.
Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Fagor MF-12 N PCB Honeywell Ref. MU0104200