Fagor PCB CE30E1N E.G.O. Control 206 Ref. 7709A05E00
RefurbishedFagorPCBs (control boards)E.G.O.

Fagor PCB CE30E1N E.G.O. Control 206 Ref. 7709A05E00

Stock · 5 units

Control PCB for Fagor boilers, with the Fagor logo printed on the circuit. The control module is manufactured by E.G.O. (E.G.O. C.S. adhesive), model CONTROL 206, code 7709A05E00, version HW:08 SW:01 RC. It includes transformer E5419266 (230V 50/60Hz on primary, 14V 12VA on secondary). It is replaced when the boiler does not ignite or does not respond to the controls.

VAT included

Compatibility

Fagor boilers compatible with reference N03G009M8

PCB with reference N03G009M8. 12 verified compatibilities: FE-24E/1 N and FE-24E/1 B.

Proven compatibility

Boiler modelFamilyVerification
Fagor FE-24E/1 NFE24EContrasted
Fagor FE-24E/1 BFE24EContrasted
Fagor FE-24E H/1 NFE24EContrasted
Fagor FE24EC/1 BFE24EContrasted
Fagor FE24EC/1 NFE24EContrasted
Fagor CA24E BCA24EContrasted
Fagor CA24E NCA24EContrasted
Fagor FA23E BFA23EContrasted
Fagor FA23E NFA23EContrasted
Fagor FE27E/1 BFE27EContrasted
Fagor FE27E/1 NFE27EContrasted
Fagor FE27ECN/1 NFE27EContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. N03G009M8 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference N03G009M8. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB N03G009M8 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite.

    Cause: The control board does not send the ignition command to the gas valve and the electrode if any internal component or the transformer fails.

    Check if there is power to the PCB and verify that there are no blown fuses before considering it faulty.

  • 02

    The boiler does not respond to the controls.

    Cause: An internal fault in the relays or the microprocessor of the PCB prevents it from responding to the commands, even though they are in good condition.

    Check if any LED or indicator on the PCB lights up when moving the controls: if there is no response, the board is not processing the signal.

  • 03

    Intermittent electronic fault in the ignition

    Cause: A cold solder joint or a component that degrades with heat causes the PCB to fail only when it is hot or after a period of operation.

    Note whether the fault occurs always when cold, always when hot, or randomly: this pattern helps to confirm if it is the PCB before replacing it.

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
F5Control board fault: internal fault in the electronic circuit causing the boiler to lockout.It is the code that the FE-24E range displays when the PCB fails internally. Check after ruling out correct power supply and connections: if the F5 persists with correct wiring and sensors, the PCB (N03G009M8) is the cause and should be replaced.
F10Fault in the control or closure of the gas valve; cannot be unlocked.Sources document that the origin may be the control circuit (the PCB) OR the gas valve itself. Verify by measuring the signal/power supply that the PCB sends to the valve: if the PCB does not correctly control the valve (signal absent or incorrect with a healthy valve), the PCB N03G009M8 is the cause. Shared cause, not exclusive to the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Fagor N03G009M8 PCB.

Catalogue reference
N03G009M8
Brand
Fagor
Type of part
PCBs (control boards)
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer of the control module
E.G.O.
Control board code
7709A05E00
Control board model
CONTROL 206
Hardware/software version
HW:08 SW:01 RC
Transformer model
E5419266
Primary transformer voltage
230V 50/60Hz
Primary current transformer
80mA/T
Secondary transformer voltage
14V 12VA
Frequently Asked Questions

Frequently asked questions about the PCB N03G009M8

Is this CE30E1N an original Fagor PCB?
It carries the Fagor logo printed on the circuit, but the control module is manufactured by E.G.O. (E.G.O. C.S. adhesive).
What is the code for this E.G.O. Control 206 PCB?
7709A05E00, printed on the E.G.O. label, model CONTROL 206.
Does this PCB work for the Fagor FE24E?
Yes, the FE24E appears in the list of boilers compatible with this CONTROL 206 PCB.
What transformer is included with this Fagor CE30E1N PCB?
Include the transformer E5419266, with 230V 50/60Hz on the primary side and 14V 12VA on the secondary side.
When should this Fagor CE30E1N PCB be replaced?
When the boiler does not ignite or does not respond to the controls.