Fagor PCB FE 24E E.G.O. Control 206 Ref. N03G009M8
Main control PCB for the Fagor FE 24E boiler and compatible models. Manufactured by E.G.O., with internal control module CONTROL 206, manufacturer code 7709405000 and customer reference Fagor N03G009M8. It manages the ignition and operation of the boiler; it is replaced when the electronic control fails and the boiler does not respond.
VAT included
Consult via WhatsAppFagor boilers compatible with reference N03G009M8
PCB with reference N03G009M8. 12 verified compatibilities: FE-24E/1 N and FE-24E/1 B.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE-24E/1 N | FE24E | Contrasted |
| Fagor FE-24E/1 B | FE24E | Contrasted |
| Fagor FE-24E H/1 N | FE24E | Contrasted |
| Fagor FE24EC/1 B | FE24E | Contrasted |
| Fagor FE24EC/1 N | FE24E | Contrasted |
| Fagor CA24E B | CA24E | Contrasted |
| Fagor CA24E N | CA24E | Contrasted |
| Fagor FA23E B | FA23E | Contrasted |
| Fagor FA23E N | FA23E | Contrasted |
| Fagor FE27E/1 B | FE27E | Contrasted |
| Fagor FE27E/1 N | FE27E | Contrasted |
| Fagor FE27ECN/1 N | FE27E | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. N03G009M8 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference N03G009M8. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB N03G009M8 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite at all.
Cause: The CONTROL 206 control module that manages the ignition has stopped working.
Check that the boiler is receiving gas and that the shut-off valve is open before declaring the PCB faulty.
- 02
The boiler does not respond to the thermostat or the controls on the panel.
Cause: The E.G.O. module on the PCB does not process the demand signal it receives.
Bypass or check the thermostat with a multimeter to rule out that the fault is in the thermostat and not in the PCB.
- 03
The display suddenly turns off and does not turn back on.
Cause: An internal fault of the main control cuts power to the display without affecting the rest of the PCB.
Cut the power for one minute to perform a reset; if the display does not return, the fault is confirmed on the PCB.
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F5 | Control board fault: internal fault in the electronic circuit causing the boiler to lockout. | It is the code that the FE-24E range displays when the PCB fails internally. Check after ruling out correct power supply and connections: if the F5 persists with correct wiring and sensors, the PCB (N03G009M8) is the cause and should be replaced. |
| F10 | Fault in the control or closure of the gas valve; cannot be unlocked. | Sources document that the origin may be the control circuit (the PCB) OR the gas valve itself. Verify by measuring the signal/power supply that the PCB sends to the valve: if the PCB does not correctly control the valve (signal absent or incorrect with a healthy valve), the PCB N03G009M8 is the cause. Shared cause, not exclusive to the PCB. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor N03G009M8 PCB.
- Catalogue reference
- N03G009M8
- Brand
- Fagor
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer code of the control module
- 7709405000
- Control board model
- CONTROL 206
- Fagor reference
- N03G009M8
- Hardware/software version
- HW:08 SW:01 RC
- Transformer model
- E5419266
- Primary transformer voltage
- 230V 50/60Hz
- Secondary transformer voltage
- 14V 12VA
- Thermal relay code
- 1135395 / E130/1051
- The logo printed on the PCB is from Fagor (the boiler brand), but the actual manufacturer of the control module is E.G.O.; it is not a Fagor board of in-house production.