Fagor PCB FE24E1N Ref. N03G002M3
Control PCB manufactured by Fagor, reference N03G002M3, confirmed both on the part's label and by external sources. It has a protection rating of IP00 and an integrated circuit marked VISUA 201. It is the main board of the boiler. Compatible with Fagor boilers CE30E1N, FE20E1N, and FE24E1N. It is replaced when the control board fails.
VAT included
Consult via WhatsAppFagor boilers compatible with reference N03G002M3
PCB with reference N03G002M3. Four confirmed compatibilities: FE-24E and FE24E1N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE-24E | Fagor Super Compact | Contrasted |
| Fagor FE24E1N | Fagor Super Compact | Contrasted |
| Fagor FE20E1N | Fagor Super Compact | Contrasted |
| Fagor CE30E1N | Fagor Super Compact | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. N03G002M3 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference N03G002M3. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB N03G002M3 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and there is no reaction on the control panel.
Cause: The control board manages the ignition; if its electronics fail, no command reaches any component.
Check that the installation's differential has not tripped and that the boiler is receiving power before suspecting the PCB.
- 02
A different fault code appears every time you try to turn on the boiler.
Cause: A PCB with intermittent faults generates erratic readings from the sensors and triggers codes that change without a pattern.
Note the codes that appear in various attempts; if they vary without logic, focus more on the PCB than on a specific sensor.
- 03
The remote control does not respond when you press any button, not even the power button.
Cause: The microcontroller on the control board is the one that receives and executes the button presses from the panel.
Check that the wiring from the control panel to the PCB is properly connected before replacing the PCB.
- 04
The boiler turns on but shuts off by itself without any visible fault code.
Cause: The PCB can lose an internal signal and interrupt the cycle without displaying the corresponding fault.
Check if the cut coincides with the start of the pump or the burner; this helps to narrow down the fault before changing the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor N03G002M3 PCB.
- Catalogue reference
- N03G002M3
- Brand
- Fagor
- Type of part
- PCBs (control boards)
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- PCB reference
- N03G002M3
- Manufacturer
- Fagor
- IP protection rating
- IP00
- Integrated circuit code
- VISUA 201 CHKSM:717AFB
- Batch/serial marking
- S048
- External sources cite more Fagor boilers compatible with this reference, but each is only cited by one source; they are not included in the datasheet until confirmed by a second independent source.