Fagor CA-24E PCB Ref. N03G007M2
The control PCB Fagor CA-24E (Ref. N03G007M2) manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler does not start, locks out, or behaves erratically, which may be reflected in the fault code F8: communication failure between the main circuit and the control panel. This part is compatible with Fagor Ecomini boilers (such as FA-23E, FEB-23E, FEB-24E, and FEB-27E) and Fagor Contract Mini (CA-24E and CE-24E). It is recommended to replace the PCB when these symptoms or fault codes occur.
VAT included
Consult via WhatsAppFagor boilers compatible with reference N03G007M2
PCB with reference N03G007M2. Six confirmed compatibilities: FA-23E and FEB-23E/1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FA-23E | Fagor Ecomini (FA-23E / FEB-23E / FEB-24E / FEB-27E) | Contrasted |
| Fagor FEB-23E/1 | Fagor Ecomini (FA-23E / FEB-23E / FEB-24E / FEB-27E) | Contrasted |
| Fagor FEB-24E/1 | Fagor Ecomini (FA-23E / FEB-23E / FEB-24E / FEB-27E) | Contrasted |
| Fagor FEB-27E | Fagor Ecomini (FA-23E / FEB-23E / FEB-24E / FEB-27E) | Contrasted |
| Fagor CA-24E | Fagor Contract Mini (CA-24E / CE-24E) | Contrasted |
| Fagor CE-24E | Fagor Contract Mini (CA-24E / CE-24E) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. N03G007M2 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference N03G007M2. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB N03G007M2 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not turn on, no indicator lights are on, and it does not respond to the buttons.
Cause: The PCB is the brain of the boiler; if it does not receive or distribute power, nothing in the unit will start.
Check if the red or green indicator lights are on and test the TEST button; if it doesn't respond either, first check the fuses and ensure that power is reaching the boiler.
- 02
The indicators are flashing with a combination of red and green that you don't know how to interpret.
Cause: That combination is a code with which the PCB signals a detected fault (pressure, flame, sensor), not necessarily that it itself is broken.
Record the exact sequence of blinks and compare it with the model's manual before replacing the PCB, as it may be indicating another part.
- 03
Pressing P1 or P2, the panel does not respond at all.
Cause: If the buttons are soldered directly onto the PCB, a fault in it renders them ineffective even if they appear intact.
Check that it is not an issue with the control panel wiring or the cover before blaming the PCB.
- 04
The boiler turns off or resets itself intermittently, without a clear fault code.
Cause: An internal fault in the PCB, due to soldering or aged components, causes irregular interruptions without a localized fault.
First, rule out power cuts, a thermostat that interrupts the command, or a loose connection, as they can cause the same symptom without the PCB failing.
Fault codes for Fagor that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F8 | Communication fault between the main circuit and the control board. | The N03G007M2 control board does not respond or communicate with the main PCB (power supply/bus/connectors/damaged PCB). Check 5 V and signal at the control board connector, continuity of the harness, and, if possible, cross-test with another N03G007M2. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fagor N03G007M2 PCB.
- Catalogue reference
- N03G007M2
- Brand
- Fagor
- Type of part
- PCBs (control boards)
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days