Plate Heat Exchanger for Chaffoteaux Elexia Comfort 24 FF Boiler
The plate heat exchanger for the Chaffoteaux Elexia Comfort 24 FF boiler transfers heat from the primary circuit to the domestic hot water instantly. When it fails, the water comes out lukewarm or with fluctuating temperature, and the flow of DHW decreases. This heat exchanger is compatible with several models from the Elexia range, such as the Comfort 01 FFPEU, as well as with models from the Maya and Niagara ranges. It is recommended to replace it when these symptoms of poor performance in hot water are detected.
VAT included
Consult via WhatsAppCompatible Chaffoteaux boilers
Plate heat exchanger. Three confirmed compatibilities: COMFORT 01 FFPEU (Chaffoteaux Elexia Comfort 24 FF) and 28 FFN.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux COMFORT 01 FFPEU (Chaffoteaux Elexia Comfort 24 FF) | ELEXIA | Contrasted |
| Chaffoteaux 28 FFN | MAYA | Contrasted |
| Chaffoteaux DELTA 01 CFPEU | NIAGARA | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the plate heat exchanger resolves
The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
There is no domestic hot water, or it comes out intermittently at a lukewarm temperature.
Cause: The heat exchanger is blocked and does not allow enough water to pass through for heating.
Check that the cold water inlet filter is clean; if it is fine and the issue persists, the problem is the heat exchanger.
- 02
The boiler turns on for heating without any problem, but it struggles to deliver hot water to the tap.
Cause: The plates are partially blocked by limescale, which slows down the heat exchange.
Let the hot water run for a minute and check if the temperature improves or remains low.
- 03
Water is leaking from one of the copper threaded connections of the heat exchanger.
Cause: Any of the connections can leak if the gasket or the thread is damaged.
Carefully tighten each threaded connection and dry the area well before assuming that the heat exchanger is the one with the leak.
- 04
The heating circuit loses pressure over time without any visible leak.
Cause: An internal crack in the heat exchanger allows water to escape from the circuit.
Close the automatic filling valve and monitor the pressure on the gauge for several days; if it continues to drop, the leak is internal.
Fault codes Chaffoteaux that this part resolves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 1 05 | Water circulation problem | Water is not circulating properly through the system. This may be due to a blockage in the plate heat exchanger. Check the water pressure and bleed the radiators if necessary. If the problem persists, it may be necessary to replace the heat exchanger. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Chaffoteaux plate heat exchanger datasheet
- Brand
- Chaffoteaux
- Type of part
- Plate heat exchanger
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Chaffoteaux DELTA 01 CFPEU Manual (PDF)Document © Chaffoteaux, provided as a technical reference.